Home › Power Source / Network · 6AR-FSE BATTERY / CHARGING › CHARGING SYSTEM

CHARGING SYSTEM > TERMINALS OF ECM

for Preparation Click here



CHECK ECM

A247842E66

HINT:
The standard normal voltage between each pair of ECM terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage for that pair of terminals, displayed in the Specified Condition column. The illustration above can be used as a reference to identify the ECM terminal locations.


Terminal No. (Symbol)
Wiring Color
Terminal Description
Condition
Specified Condition
E96-53 (E1) - Body ground
W-B - Body ground
Ground
Always
Below 1 Ω
A84-1 (BATT) - E96-53 (E1)
GR - W-B
Battery (for measuring battery voltage and for ECM memory)
Always
11 to 14 V
E96-61 (LIN) - Body ground
L - Body ground
LIN communication line
Engine switch off
10 kΩ or higher