CHARGING SYSTEM > DATA LIST / ACTIVE TEST |
| DATA LIST |
Warm up the engine.
Turn the A/C switch off.
Turn the engine switch off.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Engine / Data List.
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Battery Voltage | Battery voltage / Min.: 0.0 V, Max.: 65.5 V | 11 to 14 V (Idling) | If the result is not as specified, abnormal battery voltage is suspected. |
| BATT Voltage | BATT voltage / Min.: 0.0 V, Max.: 79.998 V | 11 to 14 V (Idling) | - |
| Alternator Output Duty Ratio | Generator output duty / Min.: 0.0%, Max.: 399.9% | Changes according to alternator output | If the result is not as specified, a malfunction of the charging system is suspected. |
| Alternator Voltage - Non Active Test | Requested voltage when regulator forced drive is not executed Min.: 0.0 V, Max.: 79.998 V | 12.5 to 14.4 V: After engine start (varies with battery temperature or driving conditions) | Active Test support data |
| Voltage of Alternator | Voltage of Alternator / Min.: 0.0 V, Max.: 79.9 V | - | - |
| ACTIVE TEST |
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Engine / Active Test.
According to the display on the GTS, perform the Active Test.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Control the Voltage of Alternator | Requested output voltage of generator regulator during forced activation | Between 12.5 and 14.8 V | Test is possible after engine start |