Home › Drivetrain › U761E (AUTOMATIC TRANSMISSION / TRANSAXLE) › AUTOMATIC TRANSAXLE SYSTEM › 2018.04–2021.02
NM33A0E _52 Drivetrain _072328 U761E AUTOMATIC TRANSMISSION / TRANSAXLE _0351294 AUTOMATIC TRANSAXLE SYSTEM DE DETAILS F

U761E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM  DETAILS  SHIFT SOLENOID VALVE  


CONSTRUCTION


a.

In order to provide a hydraulic pressure that is proportional to the current that flows to the solenoid coil, shift solenoid valves SL1, SL2, SL3, SL4, SLU and SLT linearly control the line pressure and clutch and brake engagement pressure based on the signals from the ECM.


b.

The shift solenoid valves SL1, SL2, SL3 and SL4 are high flow linear solenoid valves that can supply more pressure than conventional ones. These shift solenoid valves control engagement elements by directly regulating the line pressure without using a pressure regulation valve (control valve) or a pressure reduction valve (solenoid modulator valve). Thus, the number of valves and the length of the valve body fluid passage have been reduced, the shifting response has been increased and shift shock has been minimized.

Shift Solenoid Valve SL1/SL3
X117346E02
2.344,0.688 2.083,0.281 2.083,0.281 1.865,0.281 true 2.25,0.938 1.865,1.188 1.865,1.188 1.646,1.188 true 3.219,0.552 3.354,0.229 3.354,0.229 3.594,0.229 true 1.115,0.188 2.271,0.5 1.156,0.313 10 false Spool Valve 1.219,1.094 2.375,1.406 1.156,0.313 10 false Sleeve 3.635,0.146 4.792,0.458 1.156,0.313 10 false Solenoid 4.51,0.677 5.104,1.219 0.594,0.542 10 false Hydraulic Pressure 5.656,1.438 6.75,1.625 1.094,0.188 10 false Current

Shift Solenoid Valve SL2/SL4
X117347E02
1.948,0.344 2.125,0.344 2.125,0.344 2.365,0.698 true 1.792,1.167 1.969,1.167 1.969,1.167 2.26,0.927 true 3.667,0.25 3.469,0.25 3.469,0.25 3.344,0.552 true 1.188,0.24 2.26,0.438 1.073,0.198 10 false Spool Valve 1.354,1.073 2.427,1.271 1.073,0.198 10 false Sleeve 3.708,0.156 4.781,0.354 1.073,0.198 10 false Solenoid 5.656,1.438 6.729,1.635 1.073,0.198 10 false Current 4.49,0.656 5.104,1.208 0.615,0.552 10 false Hydraulic Pressure

Shift Solenoid Valve SLT
X117348E02
1.844,0.323 2.052,0.323 2.052,0.323 2.292,0.719 true 1.74,1.208 1.948,1.208 1.948,1.208 2.198,0.938 true 3.625,0.302 3.406,0.302 3.406,0.302 3.24,0.583 true 1.094,0.229 2.167,0.427 1.073,0.198 10 false Spool Valve 1.313,1.125 2.385,1.323 1.073,0.198 10 false Sleeve 3.677,0.208 4.75,0.406 1.073,0.198 10 false Solenoid 4.51,0.615 5.115,1.156 0.604,0.542 10 false Hydraulic Pressure 5.698,1.427 6.771,1.625 1.073,0.198 10 false Current

Shift Solenoid Valve SLU
X117349E02
1.76,0.365 1.958,0.365 1.958,0.365 2.208,0.75 true 1.802,1.219 2,1.219 2,1.219 2.24,0.938 true 3.667,0.292 3.469,0.292 3.469,0.292 3.26,0.615 true 1.01,0.271 2.698,0.469 1.688,0.198 10 false Spool Valve 1.365,1.125 3.052,1.323 1.688,0.198 10 false Sleeve 3.708,0.208 5.396,0.406 1.688,0.198 10 false Solenoid 4.49,0.542 5.083,0.979 0.594,0.438 10 false Hydraulic Pressure 5.771,1.427 6.396,1.667 0.625,0.24 10 false Current


c.

The shift solenoid valve SL is a 3-way solenoid valve.


d.

A filter is provided at the tip of the solenoid valve to further improve operational reliability.

X117350C04
4.104,0.479 4.24,0.479 4.24,0.479 4.438,0.646 true 1.031,0.5 1.167,0.5 1.167,0.5 1.365,0.667 true 3.938,0.396 4.25,0.552 0.313,0.156 10 false *1 2.063,1.5 2.375,1.656 0.313,0.156 10 false *a 5.115,1.5 5.427,1.656 0.313,0.156 10 false *b 0.875,0.417 1.188,0.573 0.313,0.156 10 false *1
*1 Strainer - -
*a Off Condition *b On Condition
V100135

Drain
V100136

Control Pressure
V100137

Modulated Pressure
V100138

Solenoid Movement


Function of Shift Solenoid Valves
Shift Solenoid Valve Function
Shift Solenoid Valve SL1 No. 1 clutch (C1) pressure control
Shift Solenoid Valve SL2 No. 2 clutch (C2) pressure control
Shift Solenoid Valve SL3 No. 1 brake (B1) pressure control
Shift Solenoid Valve SL4 No. 3 brake (B3) pressure control
Shift Solenoid Valve SLT Line pressure control
Shift Solenoid Valve SLU
·

Lock-up clutch pressure control

·

No. 2 brake (B2) pressure control


Shift Solenoid Valve SL
·

Switches the lock-up relay valve.

·

Switches the B2 apply control valve and the reverse sequence valve.