Home › Power Source / Network › 2GR-FKS (BATTERY / CHARGING) › CHARGING SYSTEM › 2018.04–2021.02
NM33A0E _57 Power Source / Network _067505 2GR-FKS BATTERY / CHARGING _0329928 CHARGING SYSTEM DE DETAILS F

2GR-FKS BATTERY / CHARGING  CHARGING SYSTEM  DETAILS  BATTERY  


CONSTRUCTION


a.

A vented type EN standard battery is used and is located in the engine compartment.



SPECIFICATION


Item Specification

*1: For European Norm (EN) battery, this refers to the battery size.

*2: Standard models

*3: Cold area specification models

*4: Destination package for Brazil

*5: Models for Russia

*6: Value indicates low-temperature starting performance.

Battery Type*1 LN2*2 LN3*3 LN2*4 LN3*5
Rated Voltage 12 V 12 V 12 V 12 V
20 Hour Rate Capacity (20HR) 60 Ah 70 Ah 60 Ah 70 Ah
Cold Cranking Ampere (CCA)*6 360 A 600 A 345 A 603 A
Ventilation Type Each Cell Vented Each Cell Vented Each Cell Vented Each Cell Vented
Indicator N/A N/A N/A N/A