Home › Vehicle Interior › HEATING / AIR CONDITIONING › SOLAR SENSOR
RM33A0E _58 Vehicle Interior _065387 HEATING / AIR CONDITIONING _0319115 SOLAR SENSOR G

HEATING / AIR CONDITIONING  SOLAR SENSOR  INSPECTION  


PROCEDURE

Hide 89120A 1.INSPECT AUTOMATIC LIGHT CONTROL SENSOR

a.
B157083C65
1.521,0.333 1.896,0.573 0.375,0.24 0.99,1.583 1.438,1.167 false 1.573,1.583 1.604,1.198 false 0.135,0.104 0.344,0.26 0.208,0.156 10 false *a 1.615,0.365 1.927,0.625 0.313,0.26 10 false M1 0.75,1.625 1.156,1.792 0.406,0.167 10 false CLTB 1.438,1.625 1.844,1.792 0.406,0.167 10 false CLTE
*a Front view of wire harness connector
(to Automatic Light Control Sensor)


Disconnect the M1 automatic light control sensor connector.


b.

Measure the voltage and resistance according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
M1-1 (CLTB) - M1-2 (CLTE) Ignition switch off Below 1 V
Ignition switch ON 11 to 14 V


Standard Resistance:
Tester Connection Condition Specified Condition
M1-2 (CLTE) - Body ground Always Below 1 Ω


If the result is not as specified, there may be a malfunction on the wire harness side.


c.

Connect the M1 automatic light control sensor connector.


d.

Connect an oscilloscope to terminals M1-2 (CLTE) and M1-4 (CLTS) of the automatic light control sensor connector and check the waveform.

E354782C05
1.708,0.875 2.083,1.104 0.375,0.229 1.99,1.656 2.427,2.198 false 1.698,1.656 1.344,2.219 false 3.917,0.75 4.229,0.948 0.313,0.198 10 false *b 1.802,0.896 2.115,1.094 0.313,0.198 10 false M1 2.375,2.229 2.854,2.448 0.479,0.219 10 false CLTE 1.135,2.25 1.615,2.469 0.479,0.219 10 false CLTS 1.031,0.74 1.344,0.938 0.313,0.198 10 false *a 6.354,2.083 6.833,2.302 0.479,0.219 10 false GND
*a Component with harness connected
(Automatic Light Control Sensor)
*b Waveform


OK:
Tester Connection Condition Tool Setting Specified Condition
M1-2 (CLTE) - M1-4 (CLTS) Ignition switch ON 2 V/DIV., 10 ms./DIV. Pulse generation
(See waveform)


HINT:

The communication waveform changes according to the surrounding brightness.


If the result is not as specified, the automatic light control sensor may be malfunctioning.