Home › Brake › BRAKE SYSTEM (OTHER) › VACUUM PUMP (for 2GR-FKS)
RM33A0E _54 Brake _065366 BRAKE SYSTEM (OTHER) _0319139 VACUUM PUMP(for 2GR-FKS) G

BRAKE SYSTEM (OTHER)  VACUUM PUMP(for 2GR-FKS)  INSPECTION  


PROCEDURE

Hide 29331A 1.INSPECT VACUUM PUMP VANE

a.
C169339C03
1.665,1.497 1.824,1.641 0.158,0.144 10 *2 0.864,1.712 1.018,1.854 0.154,0.142 10 *1 2.135,0.256 2.285,0.403 0.15,0.147 10 *1 2.707,0.665 2.707,0.339 2.707,0.339 2.32,0.339 false 1.323,1.371 1.323,1.584 1.323,1.584 1.641,1.584 false 0.529,1.532 0.529,1.8 0.529,1.8 0.841,1.8 false
*1 Vacuum Pump Vane Cap
*2 Vacuum Pump Vane


Check that the vacuum pump vane or vacuum pump vane caps are not damaged or excessively worn.

HINT:

If the vacuum pump vane or vacuum pump vane caps are damaged or excessively worn, replace the damaged parts with new ones.



b.
C169340C02
2.354,2.365 2.521,2.583 0.167,0.219 10 false A 1.271,2.365 1.438,2.583 0.167,0.219 10 false A 0.802,3 1.052,3.208 0.25,0.208 10 false *a 2.531,2.99 2.729,3.208 0.198,0.219 10 false *a
*a 10 mm (0.394 in.)


Using a micrometer, measure length (A) of the vacuum pump vane with the vacuum pump vane caps removed.

Minimum Length (A):

23.8 mm (0.937 in.)


NOTICE:

Measure the length 10 mm (0.394 in.) in from each end of the vacuum pump vane.


HINT:

If the length is not as specified, replace the vacuum pump vane and vacuum pump vane caps with new ones.



c.
C169342C05
0.948,1.969 0.948,1.719 0.948,1.719 1.406,1.719 false 2.448,2.625 2.448,2.875 false 0.552,2.625 0.552,2.875 false 1.479,2.302 1.615,2.469 0.135,0.167 10 false B 2.729,1.969 2.958,2.188 0.229,0.219 10 false *a 2.74,2.469 3,2.656 0.26,0.188 10 false *a 1.479,1.656 1.646,1.823 0.167,0.167 10 false *1 2.365,2.938 2.531,3.104 0.167,0.167 10 false *2 0.458,2.927 0.625,3.094 0.167,0.167 10 false *2 1.479,1.99 1.615,2.156 0.135,0.167 10 false B
*1 Vacuum Pump Vane
*2 Vacuum Pump Vane Cap
*a 5 mm (0.197 in.)


Using a vernier caliper, measure length (B) of the vacuum pump vane with the vacuum pump vane caps installed.

Minimum Length (B):

80.5 mm (3.17 in.)


NOTICE:

Measure the length 5 mm (0.197 in.) in from each end of the vacuum pump vane caps.


HINT:

If the length is not as specified, replace the vacuum pump vane and vacuum pump vane caps with new ones.



Hide 2.INSPECT VACUUM PUMP HOUSING

a.
C338031

Check that the areas shown in the illustration are not damaged or excessively worn.

HINT:

If the areas shown in the illustration are damaged or excessively worn, replace the vacuum pump assembly.