The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed, installed, or replaced during the water inlet with thermostat sub-assembly removal/installation are shown below.
This procedure includes the removal of small-head bolts. Refer to Small-Head Bolts of Basic Repair Hint to identify the small-head bolts.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
1.DRAIN ENGINE COOLANT
27020
2.REMOVE GENERATOR ASSEMBLY
16572D
3.DISCONNECT NO. 2 RADIATOR HOSE
16031
4.REMOVE WATER INLET WITH THERMOSTAT SUB-ASSEMBLY
Disconnect the water inlet with thermostat sub-assembly connector.
Slide the clip and disconnect the No. 7 water by-pass hose from the water inlet with thermostat sub-assembly.
Do not apply force to the water inlet with thermostat sub-assembly when disconnecting the No. 7 water by-pass hose.
Do not damage the water inlet with thermostat sub-assembly.
When disconnecting the No. 7 water by-pass hose, slide the clip, rotate the hose and pull it straight off the pipe.
Using an 8 mm socket wrench, remove the 2 bolts and water inlet with thermostat sub-assembly.
Remove the gasket from the water inlet with thermostat sub-assembly.