Home › Engine / Hybrid System › A25A-FKS (COOLING) › FLOW SHUTTING VALVE (for Heater)
RM33A0E _51 Engine / Hybrid System _065346 A25A-FKS COOLING _0319574 FLOW SHUTTING VALVE(for Heater) A

A25A-FKS COOLING  FLOW SHUTTING VALVE(for Heater)  INSTALLATION  


PROCEDURE

Hide 16260 1.INSTALL FLOW SHUTTING VALVE (WATER BY-PASS HOSE ASSEMBLY)

a.

Connect the flow shutting valve (water by-pass hose assembly) to the transmission oil cooler and slide the clip to secure it.

A402663C01
2,1.021 1.646,1.063 1.646,1.063 1.99,0.865 false 2.604,0.771 2.917,0.927 0.313,0.156 10 false *a 1.458,1 1.771,1.156 0.313,0.156 10 false *b 2.229,1.469 2.542,1.625 0.313,0.156 10 false *c 1.688,1.458 2,1.615 0.313,0.156 10 false *c
*a 2 to 7 mm (0.0787 to 0.276 in.) *b Paint Mark
*c 45° (Tabs of Clip Installation Area) - -


NOTICE:
·

Make sure to slide the flow shutting valve (water by-pass hose assembly) until it contacts the hose stopper of the transmission oil cooler.

·

Make sure to align the paint mark of the flow shutting valve (water by-pass hose assembly) with the paint mark of the transmission oil cooler.

·

Make sure that the tabs of the clip are within the area shown in the illustration.




b.
A402665C01
1.479,3.854 1.292,3.854 1.292,3.854 1.042,3.344 false 1.521,3.76 1.833,3.917 0.313,0.156 10 false *a 2.969,2.906 3.281,3.063 0.313,0.156 10 false *b 2.969,3.573 3.281,3.729 0.313,0.156 10 false *b
*a Paint Mark
*b 45° (Tabs of Clip Installation Area)


Connect the flow shutting valve (water by-pass hose assembly) to the water by-pass outlet sub-assembly and slide the clip to secure it.

NOTICE:
·

Make sure to slide the flow shutting valve (water by-pass hose assembly) until it contacts the hose stopper of the water by-pass outlet sub-assembly.

·

Make sure that the tabs of the clip are within the area shown in the illustration.




c.

Install the water hose clamp bracket with the 2 bolts.

Torque:
13 N*m (133 kgf*cm, 10 ft.*lbf)


d.

Engage the 2 clamps to connect the wire harness.


e.

Connect the flow shutting valve (water by-pass hose assembly) with the bolt.

Torque:
19 N*m (194 kgf*cm, 14 ft.*lbf)


f.

Connect the No. 2 water by-pass pipe sub-assembly with the bolt.

Torque:
19 N*m (194 kgf*cm, 14 ft.*lbf)


g.

Connect the inlet heater hose connector to the flow shutting valve (water by-pass hose assembly).

NOTICE:

Check that there is no damage or foreign matter on the connecting parts of the water lines.


i.
A403462C01
1.01,0.979 1.438,0.979 false 1.875,0.969 2.302,0.969 false 1.021,1.354 1.448,1.354 false 1.844,1.365 2.281,1.917 2.281,1.917 2.594,1.917 false 0.813,0.885 1.125,1.042 0.313,0.156 10 false *a 0.833,1.271 1.146,1.427 0.313,0.156 10 false *b 2.365,0.896 2.677,1.052 0.313,0.156 10 false *a 2.635,1.844 2.948,2 0.313,0.156 10 false *b
*a Protrusion
*b Cutout


Align the protrusions of the inlet heater hose connector with the cutouts in the flow shutting valve (water by-pass hose assembly) and push them together until the inlet heater hose connector makes a "click" sound.


ii.
A402657C01
1.365,1.115 1.688,0.49 1.688,0.49 1.917,0.49 false 1.969,0.406 2.281,0.563 0.313,0.156 10 false *a
*a Retainer
V100135

Push
V100136

Push in


Push in the retainer.


iii.

Check that the flow shutting valve (water by-pass hose assembly) and inlet heater hose connector are securely connected by pulling on them.



h.

Connect the outlet heater hose connector to the No. 2 water by-pass pipe sub-assembly.

NOTICE:

Check that there is no damage or foreign matter on the connecting parts of the water lines.


i.
A403463C01
1.052,1.156 1.573,1.156 false 0.99,0.365 1.219,0.365 1.219,0.365 1.521,0.792 false 0.875,1.063 1.188,1.219 0.313,0.156 10 false *a 0.823,0.281 1.135,0.438 0.313,0.156 10 false *b
*a Protrusion
*b Cutout


Align the protrusion of the No. 2 water by-pass pipe sub-assembly with the cutout in the outlet heater hose connector and push them together until the outlet heater hose connector makes a "click" sound.


ii.
A402654C01
2.26,1.521 2.073,1.521 2.073,1.521 1.771,1.188 false 2.323,1.438 2.563,1.635 0.24,0.198 10 true *a
*a Retainer
V100135

Push
V100136

Push in


Push in the retainer.


iii.

Check that the No. 2 water by-pass pipe sub-assembly and outlet heater hose connector are securely connected by pulling on them.



i.

Engage the clamp to connect the engine wire harness to the water hose clamp bracket.


j.

Connect the 3 connectors.


k.

Engage the clamp to connect the vacuum hose to the engine wire harness.


Hide 16261G 2.INSTALL FLOW SHUTTING VALVE (NO. 1 WATER BY-PASS HOSE)