Home › Drivetrain › U760E (AUTOMATIC TRANSMISSION / TRANSAXLE) › VALVE BODY ASSEMBLY › 2017.09–2021.02
RM33A0E _52 Drivetrain _065350 U760E AUTOMATIC TRANSMISSION / TRANSAXLE _0321091 VALVE BODY ASSEMBLY G

U760E AUTOMATIC TRANSMISSION / TRANSAXLE  VALVE BODY ASSEMBLY  INSPECTION  


PROCEDURE

Hide 35240 1.INSPECT SOLENOID (SL) VALVE

a.
C188295C05
0.158,0.099 0.355,0.264 0.197,0.164 10 *a
*a Component without harness connected
(Solenoid (SL) Valve)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Solenoid (SL) valve connector terminal - Solenoid (SL) valve body 20°C (68°F) 11 to 15 Ω


If the result is not as specified, replace the solenoid (SL) valve.



b.

Connect a battery positive (+) lead to the terminal of the solenoid valve connector, and a negative (-) lead to the solenoid body. Then check that the valve moves and makes an operating sound.

NOTICE:

When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.


OK:

Valve moves and makes an operating sound.


If the result is not as specified, replace the solenoid (SL) valve.



Hide 35290 2.INSPECT SOLENOID (SLT) VALVE

a.
C201747C05
0.493,0.48 0.674,0.675 0.18,0.195 10 1 2.533,0.48 2.713,0.675 0.18,0.195 10 2 1.163,4.15 1.372,4.356 0.209,0.206 10 (-) 1.919,4.15 2.147,4.35 0.228,0.2 10 (+) 1.509,0.804 0.652,0.57 false 1.785,0.789 2.479,0.549 false 0.493,2.733 0.674,2.928 0.18,0.195 10 1 2.533,2.733 2.713,2.928 0.18,0.195 10 2 1.509,3.056 0.652,2.823 false 1.785,3.042 2.479,2.802 false 0.135,0.025 0.357,0.231 0.222,0.206 10 *a
*a Component without harness connected
(Solenoid (SLT) Valve)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω


If the result is not as specified, replace the solenoid (SLT) valve.


b.

Connect a battery positive (+) lead with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating sound.

NOTICE:

When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.


OK:

Valve moves and makes an operating sound.


If the result is not as specified, replace the solenoid (SLT) valve.


Hide 35280 3.INSPECT SOLENOID (SLU) VALVE

HINT:

Refer to Inspect solenoid (SL) valve.


Hide 35210 4.INSPECT SOLENOID (SL1) VALVE

HINT:

Refer to Inspect solenoid (SL) valve.


Hide 35220 5.INSPECT SOLENOID (SL2) VALVE

HINT:

Refer to Inspect solenoid (SL) valve.


Hide 6.INSPECT SOLENOID (SL3) VALVE

HINT:

Refer to Inspect solenoid (SL) valve.


Hide 7.INSPECT SOLENOID (SL4) VALVE

HINT:

Refer to Inspect solenoid (SL) valve.