Home › Drivetrain › UB80E (AUTOMATIC TRANSMISSION / TRANSAXLE) › VALVE BODY ASSEMBLY
RM33A0E _52 Drivetrain _065352 UB80E AUTOMATIC TRANSMISSION / TRANSAXLE _0321821 VALVE BODY ASSEMBLY G

UB80E AUTOMATIC TRANSMISSION / TRANSAXLE  VALVE BODY ASSEMBLY  INSPECTION  


PROCEDURE

Hide 35240D 1.INSPECT SOLENOID (SL) VALVE

a.
C209925C05
0.083,0.063 0.396,0.219 0.313,0.156 10 false *a 1.594,0.25 2.094,0.448 0.5,0.198 10 false ( - ) 2.438,0.25 2.896,0.49 0.458,0.24 10 false ( + )
*a Component without harness connected
(Solenoid (SL) Valve)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Solenoid (SL) valve connector terminal - Solenoid (SL) valve body 20°C (68°F) 11 to 15 Ω


If the result is not as specified, replace the solenoid (SL) valve.


b.

Connect a positive (+) lead from the battery to the terminal of the solenoid (SL) valve connector and a negative (-) lead to the solenoid (SL) valve body, and check that the solenoid (SL) valve moves and makes an operating sound.

NOTICE:

When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.


OK:

The solenoid (SL) valve moves and makes an operating sound.


If the result is not as specified, replace the solenoid (SL) valve.


Hide 35290C 2.INSPECT SOLENOID (SLT) VALVE

a.
C201747C19
1,0.583 1.427,0.823 true 1,2.833 1.427,3.073 true 1.823,0.813 2.25,0.583 true 1.823,3.073 2.25,2.833 true 0.865,0.469 1.021,0.667 0.156,0.198 10 false 1 2.344,0.479 2.573,0.677 0.229,0.198 10 false 2 1.115,4.25 1.531,4.5 0.417,0.25 10 false ( - ) 1.917,4.25 2.323,4.5 0.406,0.25 10 false ( + ) 0.875,2.719 1.052,2.917 0.177,0.198 10 false 1 2.333,2.719 2.51,2.917 0.177,0.198 10 false 2 0.167,0.167 0.5,0.5 0.333,0.333 10 false *a
*a Component without harness connected
(Solenoid (SLT) Valve)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω


If the result is not as specified, replace the solenoid (SLT) valve.


b.

Connect a positive (+) lead from the battery with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid (SLT) valve connector, and check that the solenoid (SLT) valve moves and makes an operating sound.

NOTICE:

When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.


OK:

The solenoid (SLT) valve moves and makes an operating sound.


If the result is not as specified, replace the solenoid (SLT) valve.


Hide 35280A 3.INSPECT SOLENOID (SLU) VALVE

HINT:

Refer to Inspect Solenoid (SLT) Valve.


Hide 35210A 4.INSPECT SOLENOID (SL1) VALVE

HINT:

Refer to Inspect Solenoid (SLT) Valve.


Hide 35210C 5.INSPECT SOLENOID (SL2) VALVE

HINT:

Refer to Inspect Solenoid (SLT) Valve.


Hide 35210B 6.INSPECT SOLENOID (SL3) VALVE

HINT:

Refer to Inspect Solenoid (SLT) Valve.


Hide 35210D 7.INSPECT SOLENOID (SL4) VALVE

HINT:

Refer to Inspect Solenoid (SLT) Valve.


Hide 35210E 8.INSPECT SOLENOID (SL5) VALVE

HINT:

Refer to Inspect Solenoid (SLT) Valve.


Hide 35210F 9.INSPECT SOLENOID (SL6) VALVE

HINT: