Home › Drivetrain › U760E (AUTOMATIC TRANSMISSION / TRANSAXLE) › AUTOMATIC TRANSAXLE SYSTEM › 2017.09–2021.02
RM33A0E _52 Drivetrain _065350 U760E AUTOMATIC TRANSMISSION / TRANSAXLE _0322783 AUTOMATIC TRANSAXLE SYSTEM U

U760E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM  FAIL-SAFE CHART  


Fail-safe


The fail-safe function minimizes the loss of operation when a malfunction occurs in a sensor or solenoid.

Fail-safe Control List
Malfunctioning Part Function
Input Speed Sensor NT Shifting to only 1st or 3rd gear is allowed.
Output Speed Sensor NC
·

The counter gear speed is determined based on signals from the skid control ECU (speed sensor signals).

·

Shifting between 1st to 4th gear is allowed.


ATF Temperature Sensor Shifting between 1st to 4th gear is allowed.
ECM
Power Supply (Voltage is Low)
When the vehicle is being driven in 6th gear, the transaxle is fixed in 6th gear. When being driven in 1st to 5th gear, the transaxle is fixed in 5th gear.
CAN communication Shifting to only 1st or 3rd gear is allowed.
Knock Sensor Shifting between 1st to 4th gear is allowed.
Solenoid (SL1, SL2, SL3 and SL4) Valve The current to the failed solenoid valve is cut off and operating the other solenoid valves with normal operation performs shift control. (Shift controls in fail-safe mode are described in the table on the next page. For details, refer to Fail-Safe Control Chart.)

Solenoid Valve Operation when Normal
Gear Position 1st 2nd 3rd 4th 5th 6th
Solenoid (SL1) Valve ON ON ON ON OFF OFF
Solenoid (SL2) Valve OFF OFF OFF ON ON ON
Solenoid (SL3) Valve OFF ON OFF OFF OFF ON
Solenoid (SL4) Valve OFF OFF ON OFF ON OFF

Fail-safe Control Chart
Gear in Normal Conditions 1st 2nd 3rd 4th 5th 6th
Solenoid (SL1) Valve ON Malfunction (without Fail-safe Control)* 1st 2nd 3rd 4th 4th 4th
OFF Malfunction (without Fail-safe Control) 1st to N 2nd to N 3rd to N 4th to N 5th 6th
Fail-safe Control during OFF Malfunction Fixed in 3rd or 5th
Solenoid (SL2) Valve ON Malfunction (without Fail-safe Control)* 1st to 4th 2nd to 4th 3rd to 4th 4th 5th 6th
OFF Malfunction (without Fail-safe Control) 1st 2nd 3rd 4th to 1st 5th to N 6th to N
Fail-safe Control during OFF Malfunction Fixed in 2nd or 3rd
Solenoid (SL3) Valve ON Malfunction (without Fail-safe Control)* 1st to 2nd 2nd 3rd 4th 5th 6th
OFF Malfunction (without Fail-safe Control) 1st 2nd to 1st 3rd 4th 5th 6th to N
Fail-safe Control during OFF Malfunction Fixed in 3rd
Solenoid (SL4) Valve ON Malfunction (without Fail-safe Control)* 3rd 3rd 3rd 4th 5th 5th
OFF Malfunction (without Fail-safe Control) 1st 2nd 3rd to 1st 4th 5th to N 6th
Fail-safe Control during OFF Malfunction Fixed in 2nd

*: Fail-safe control is not actuated when an ON malfunction occurs.