Home › Power Source / Network › A25A-FKS (BATTERY / CHARGING) › CHARGING SYSTEM
RM33A0E _57 Power Source / Network _065349 A25A-FKS BATTERY / CHARGING _0328306 CHARGING SYSTEM U

A25A-FKS BATTERY / CHARGING  CHARGING SYSTEM  TERMINALS OF ECM  


B460712E06
5.49,0.917 5.823,1.156 0.333,0.24 2.01,0.917 2.385,1.156 0.375,0.24 3.885,0.927 4.26,1.167 0.375,0.24 5.531,0.958 5.99,1.156 0.458,0.198 10 false A24 2.083,0.958 2.542,1.156 0.458,0.198 10 false C57 3.958,0.969 4.417,1.167 0.458,0.198 10 false C59

HINT:

The standard normal voltage and resistance between each pair of ECM terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage and resistance for that pair of terminals, displayed in the Specified Condition column. The illustration above can be used as a reference to identify the ECM terminal locations.


Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
A24-10 (E1) - Body ground W-B - Body ground Ground Always Below 1 Ω
A24-1 (BATT) - A24-10 (E1) G - W-B Battery
(for measuring battery voltage and for ECM memory)
Always 11 to 14 V
C57-62 (LIN) - Body ground B - Body ground LIN communication line Engine switch off
(while LIN communication stopped)
10 kΩ or higher