Home › Engine / Hybrid System › 2AR-FE (INTAKE / EXHAUST) › VACUUM SWITCHING VALVE (for ACIS) › 2017.09–2021.02
RM33A0E _51 Engine / Hybrid System _065327 2AR-FE INTAKE / EXHAUST _0328639 VACUUM SWITCHING VALVE(for ACIS) A

2AR-FE INTAKE / EXHAUST  VACUUM SWITCHING VALVE(for ACIS)  INSTALLATION  


PROCEDURE

Hide 17650 1.INSTALL VACUUM SWITCHING VALVE ASSEMBLY (for ACIS)

a.

Install the vacuum hose clamp to the vacuum switching valve assembly (for ACIS) with the bolt.

Torque:
5.4 N*m (55 kgf*cm, 48 in.*lbf)


b.

Install the vacuum switching valve assembly (for ACIS) to the intake manifold with the bolt.

Torque:
9.0 N*m (92 kgf*cm, 80 in.*lbf)


c.

Connect the vacuum switching valve assembly (for ACIS) connector.


d.

Connect the 2 vacuum hoses.


e.

Engage the wire harness clamp.


f.

Connect the union to connector tube hose to the vacuum hose clamp. (for LHD)


g.

Connect the union to check valve hose to the vacuum hose clamp. (for RHD)