A25A-FKS EMISSION CONTROL  CANISTER(w/o Canister Pump Module)  INSPECTION  


PROCEDURE

Hide 1.CHECK CANISTER (FUEL SUCTION PLATE SUB-ASSEMBLY)

a.

Visually check the canister (fuel suction plate sub-assembly).

i.

Visually check the canister (fuel suction plate sub-assembly) for cracks or damage.

If cracks or damage are found, replace the canister (fuel suction plate sub-assembly).



b.

Inspect the airflow of the canister (fuel suction plate sub-assembly).

i.
A324770C02
0.594,1.938 0.781,1.938 0.781,1.938 1.823,1.208 true 1.073,0.313 1.229,0.313 1.229,0.313 1.365,0.688 false 2.177,0.708 2.083,0.708 2.083,0.708 2,0.958 false 0.406,1.833 0.625,2.031 0.219,0.198 10 false *c 0.833,0.24 1.146,0.396 0.313,0.156 10 false *a 2.229,0.625 2.438,0.844 0.208,0.219 10 true *b 2.24,0.365 2.469,0.573 0.229,0.208 10 false *d
*a Port (A)
*b Port (B)
*c Port (C)
*d Air


Close the port (B) and check that air flows from the port (C) when air is blown into the port (A).

OK:

Air flows from the port (C).




c.

Inspect the check valve.

i.
A324771C02
1.427,0.198 1.604,0.198 1.604,0.198 1.708,0.479 false 2.396,0.792 2.635,0.583 2.635,0.583 2.792,0.583 false 2.188,1.042 1.865,2.021 1.865,2.021 1.708,2.021 true 1.51,1.938 1.719,2.125 0.208,0.188 10 true *c 1.219,0.125 1.531,0.281 0.313,0.156 10 false *a 2.865,0.49 3.208,0.823 0.344,0.333 10 false *b 2.531,0.156 2.844,0.354 0.313,0.198 10 false *d
*a Port (A)
*b Port (B)
*c Port (C)
*d Air


Close the port (C) and check that air flows from the port (B) when air is blown into the port (A).

OK:

Air flows from the port (B).



ii.
A310377C02
1.531,0.25 1.948,0.25 false 1.656,1.781 1.479,1.479 1.479,1.479 1.333,1.479 false 2.313,2.313 2.917,2.313 true 2.458,2.094 2.823,1.49 2.823,1.49 3.021,1.49 true 1.115,1.396 1.427,1.635 0.313,0.24 10 false *a 3.073,1.427 3.385,1.677 0.313,0.25 10 false *b 3,2.24 3.219,2.49 0.219,0.25 10 false *c 2.01,0.156 2.229,0.406 0.219,0.25 10 false *d
*a Port (A)
*b Port (B)
*c Port (C)
*d Vacuum Pump


Using a vacuum pump, apply vacuum to the port (A) with the port (C) closed and check that air flows into the port (B).

OK:

The vacuum is maintained at first. By gradually increasing the vacuum, air flows and the vacuum decreases after the vacuum reaches a certain level.