This circuit provides power to operate the forward recognition camera.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
| *a | Front view of wire harness connector
(to Forward Recognition Camera) |
Disconnect the V6 forward recognition camera connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| V6-7 (IGB) - Body ground | Ignition switch ON | 11 to 14 V |
Turn the ignition switch off.
Connect the V6 forward recognition camera connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Forward Recognition Camera) |
Disconnect the V6 forward recognition camera connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| V6-10 (GND) - Body ground | Always | Below 1 Ω |
Connect the V6 forward recognition camera connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG