85940
1.INSPECT WIPER RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied between terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the WIPER relay.
85942
2.INSPECT WASHER RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied between terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the WASHER relay.
3.INSPECT WSH NZL HTR RELAY (w/ Washer Nozzle Heater System)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied between terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the WSH NZL HTR relay.