Home › Drivetrain › U761E (AUTOMATIC TRANSMISSION / TRANSAXLE) › VALVE BODY ASSEMBLY › 2018.04–2021.02
RM33A0E _52 Drivetrain _072210 U761E AUTOMATIC TRANSMISSION / TRANSAXLE _0351187 VALVE BODY ASSEMBLY G

U761E AUTOMATIC TRANSMISSION / TRANSAXLE  VALVE BODY ASSEMBLY  INSPECTION  


PROCEDURE

Hide 35240 1.INSPECT SOLENOID (SL) VALVE

a.
C188295C01
0.158,0.099 0.355,0.264 0.197,0.164 10 *a
*a Component without harness connected
(Solenoid (SL) Valve)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Solenoid Connector (SL) - Solenoid Body (SL) 20°C (68°F) 11 to 15 Ω


If the result is not as specified, replace the solenoid (SL) valve.


b.

Connect a positive (+) lead from the battery to the terminal of the solenoid (SL) valve connector and a negative (-) lead to the solenoid (SL) valve body, and check that the solenoid (SL) valve moves and makes an operating sound.

NOTICE:

When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.


OK:

The solenoid (SL) valve moves and makes an operating sound.


If the result is not as specified, replace the solenoid (SL) valve.


Hide 35290 2.INSPECT SOLENOID (SLT) VALVE

a.
C201747C11
1.448,0.865 0.594,0.635 true 1.802,0.865 2.5,0.625 true 1.438,3.135 0.583,2.906 true 1.823,3.115 2.521,2.875 true 0.5,0.542 0.677,0.74 0.177,0.198 10 false 1 2.542,0.531 2.719,0.729 0.177,0.198 10 false 2 1.167,4.188 1.375,4.396 0.208,0.208 10 false (-) 1.917,4.188 2.146,4.385 0.229,0.198 10 false (+) 0.49,2.802 0.667,3 0.177,0.198 10 false 1 2.563,2.771 2.74,2.969 0.177,0.198 10 false 2 0.052,0.063 0.271,0.271 0.219,0.208 10 false *a 2.823,3.563 3.135,3.76 0.313,0.198 10 false *b
*a Component without harness connected
(Solenoid (SLT) Valve)
*b 21 W Bulb


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω


If the result is not as specified, replace the solenoid (SLT) valve.


b.

Connect a positive (+) lead from the battery with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid (SLT) valve connector, and check that the solenoid (SLT) valve moves and makes an operating sound.

NOTICE:

When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.


OK:

The solenoid (SLT) valve moves and makes an operating sound.


If the result is not as specified, replace the solenoid (SLT) valve.


Hide 35280 3.INSPECT SOLENOID (SLU) VALVE

HINT:

Use the same procedure as for the solenoid (SLT) valve.


Hide 35210 4.INSPECT SOLENOID (SL1) VALVE

HINT:

Use the same procedure as for the solenoid (SLT) valve.


Hide 35220A 5.INSPECT SOLENOID (SL2) VALVE

HINT:

Use the same procedure as for the solenoid (SLT) valve.


Hide 35210 6.INSPECT SOLENOID (SL3) VALVE

HINT:

Use the same procedure as for the solenoid (SLT) valve.


Hide 35220A 7.INSPECT SOLENOID (SL4) VALVE

HINT:

Use the same procedure as for the solenoid (SLT) valve.