Home › Vehicle Exterior › MIRROR (EXT) › OUTER MIRROR SWITCH › 2018.04–2021.02
RM33A0E _59 Vehicle Exterior _065393 MIRROR (EXT) _0327585 OUTER MIRROR SWITCH G

MIRROR (EXT)  OUTER MIRROR SWITCH  INSPECTION  


PROCEDURE

Hide 84870A 1.INSPECT OUTER MIRROR SWITCH ASSEMBLY (w/ Memory)

a.

Check the mirror select and surface adjust switch. (w/o Automatic Retractable Mirror)

i.
B364152C06
1.729,1.073 1.729,0.458 1.729,0.458 1.938,0.458 true 2.073,3.74 2.24,4.073 true 1.885,4.125 1.885,3.75 true 1.448,4.073 1.552,3.76 true 2,0.344 2.313,0.5 0.313,0.156 10 false *a 0.604,2.76 0.854,2.969 0.25,0.208 10 false *b 2.292,4.125 2.51,4.344 0.219,0.219 10 false E 1.74,4.146 2.146,4.344 0.406,0.198 10 false MSW 1.354,4.104 1.719,4.365 0.365,0.26 10 false M+
*a Mirror Select and Surface Adjust Switch
*b Component without harness connected
(Outer Mirror Switch Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
15 (M+) - 12 (E) Mirror surface adjust switch pushed up 90 to 110 Ω
Mirror surface adjust switch pushed down 437 to 503 Ω
Mirror surface adjust switch pushed left 744 to 856 Ω
Mirror surface adjust switch pushed right 225 to 275 Ω
Mirror surface adjust switch not pushed 10 kΩ or higher
13 (MSW) - 12 (E) Mirror select switch turned to R position Below 1 Ω
Mirror select switch turned to L position 90 to 110 Ω
Mirror select switch off 10 kΩ or higher


If the result is not as specified, replace the outer mirror switch assembly.



b.

Check that the LED illuminates. (w/o Automatic Retractable Mirror)

i.
B364152C05
1.177,4.167 1.417,3.76 true 1.74,3.76 1.99,4.156 true 0.583,2.844 0.896,3 0.313,0.156 10 false *a 2,4.167 2.438,4.375 0.438,0.208 10 false ILL+ 0.979,4.167 1.385,4.365 0.406,0.198 10 false ILL-
*a Component without harness connected
(Outer Mirror Switch Assembly)


Apply battery voltage to the outer mirror switch assembly and check that the LED illuminates.

OK:
Battery Connection Specified Condition
Battery positive (+) - 14 (ILL+)
Battery negative (-) - 16 (ILL-)
LED illuminates


If the result is not as specified, replace the outer mirror switch assembly.



c.
B508422C01
2.063,1.219 2.063,0.542 2.063,0.542 2.333,0.542 false 1.188,1.281 1.188,0.51 1.188,0.51 0.938,0.51 false 0.5,4.25 1.083,3.708 false 1,4.25 1.25,3.698 false 1.5,4.25 1.396,3.708 false 2,4.25 1.552,3.729 false 2.417,4.25 1.906,3.729 false 2.833,4.25 2.208,3.719 false 2.375,0.448 2.688,0.604 0.313,0.156 10 false *a 0.74,0.438 1.052,0.594 0.313,0.156 10 false *b 0.375,2.719 0.688,2.875 0.313,0.156 10 false *c 0.365,4.271 0.865,4.479 0.5,0.208 10 false E2 0.865,4.292 1.24,4.469 0.375,0.177 10 false MAT 1.479,4.292 1.792,4.448 0.313,0.156 10 false E 1.844,4.292 2.271,4.479 0.427,0.188 10 false MSW 2.385,4.292 2.698,4.448 0.313,0.156 10 false M+ 2.792,4.281 3.104,4.438 0.313,0.156 10 false MR
*a Mirror Select and Surface Adjust Switch
*b Retractable Outer Mirror Switch
*c Component without harness connected
(Outer Mirror Switch Assembly)


Check the mirror select and surface adjust switch. (w/ Automatic Retractable Mirror)

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
13 (M+) - 16 (E) Mirror surface adjust switch pushed up 90 to 110 Ω
Mirror surface adjust switch pushed down 437 to 503 Ω
Mirror surface adjust switch pushed left 744 to 856 Ω
Mirror surface adjust switch pushed right 225 to 275 Ω
Mirror surface adjust switch not pushed 10 kΩ or higher
15 (MSW) - 16 (E) Mirror select switch turned to R position Below 1 Ω
Mirror select switch turned to L position 90 to 110 Ω
Mirror select switch off 10 kΩ or higher


If the result is not as specified, replace the outer mirror switch assembly.



d.

Check the mirror retract switch. (w/ Automatic Retractable Mirror)

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
17 (MAT) - 18 (E2) Extend position 10 kΩ or higher
AUTO position Below 1 Ω
11 (MR) - 18 (E2) Retract position Below 1 Ω


If the result is not as specified, replace the outer mirror switch assembly.



e.
B508422C02
1.552,4.115 1.74,3.719 false 2.26,4.125 2.042,3.74 false 0.313,2.646 0.625,2.802 0.313,0.156 10 false *a 1.375,4.125 1.771,4.313 0.396,0.188 10 false ILL+ 2.208,4.167 2.615,4.365 0.406,0.198 10 false ILL-
*a Component without harness connected
(Outer Mirror Switch Assembly)


Check that the LED illuminates. (w/ Automatic Retractable Mirror)

i.

Apply battery voltage to the outer mirror switch assembly and check that the LED illuminates.

OK:
Battery Connection Specified Condition
Battery positive (+) - 14 (ILL+) LED illuminates
Battery negative (-) - 12 (ILL-)


If the result is not as specified, replace the outer mirror switch assembly.



Hide 84870A 2.INSPECT OUTER MIRROR SWITCH ASSEMBLY (w/o Memory)

a.

Check the mirror select and surface adjust switch. (for LHD, w/ Power Retract Mirror)

i.
B491092C01
1.167,0.948 1.167,0.448 1.167,0.448 0.917,0.448 true 2.031,0.979 2.031,0.396 2.031,0.396 2.281,0.396 true 3.083,4.167 2.75,3.583 true 2.052,4.156 1.969,3.573 true 2.75,4.167 2.573,3.594 true 2.417,4.167 2.177,3.594 true 1.771,4.167 1.771,3.583 true 1.417,4.167 1.583,3.594 true 1.063,4.167 1.396,3.583 true 0.802,3.219 0.802,2.635 true 1,3.219 1.167,2.635 true 2.313,0.302 2.625,0.5 0.313,0.198 10 false *a 0.729,0.344 1.042,0.542 0.313,0.198 10 false *b 0.25,2.583 0.563,2.781 0.313,0.198 10 false *c 0.76,2.417 0.917,2.615 0.156,0.198 10 false E 1.104,2.427 1.417,2.625 0.313,0.198 10 false MF 0.958,4.188 1.271,4.385 0.313,0.198 10 false M+ 1.313,4.188 1.625,4.385 0.313,0.198 10 false VR 1.688,4.188 2,4.385 0.313,0.198 10 false HR 2.01,4.177 2.323,4.375 0.313,0.198 10 false VL 2.365,4.188 2.677,4.385 0.313,0.198 10 false HL 2.729,4.188 2.885,4.385 0.156,0.198 10 false B 3.021,4.188 3.333,4.385 0.313,0.198 10 false MR
*a Mirror Select and Surface Adjust Switch
*b Retractable Outer Mirror Switch
*c Component without harness connected
(Outer Mirror Switch Assembly)


Turn the mirror select switch to the L position.


ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (for left side):
Tester Connection Condition Specified Condition
10 (VL) - 7 (B)
13 (M+) - 5 (E)
Up Below 2 Ω
Off 10 kΩ or higher
10 (VL) - 5 (E)
13 (M+) - 7 (B)
Down Below 2 Ω
Off 10 kΩ or higher
9 (HL) - 7 (B)
13 (M+) - 5 (E)
Left Below 2 Ω
Off 10 kΩ or higher
9 (HL) - 5 (E)
13 (M+) - 7 (B)
Right Below 2 Ω
Off 10 kΩ or higher



iii.

Turn the mirror select switch to the R position.


iv.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (for right side):
Tester Connection Condition Specified Condition
12 (VR) - 7 (B)
13 (M+) - 5 (E)
Up Below 2 Ω
Off 10 kΩ or higher
12 (VR) - 5 (E)
13 (M+) - 7 (B)
Down Below 2 Ω
Off 10 kΩ or higher
11 (HR) - 7 (B)
13 (M+) - 5 (E)
Left Below 2 Ω
Off 10 kΩ or higher
11 (HR) - 5 (E)
13 (M+) - 7 (B)
Right Below 2 Ω
Off 10 kΩ or higher


If the result is not as specified, replace the outer mirror switch assembly.



b.

Check the Retractable Outer Mirror Switch. (for LHD, w/ Power Retract Mirror)

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
4 (MF) - 5 (E) Extend position 10 kΩ or higher
Except extend position Below 1 Ω
6 (MR) - 5 (E) Retract position 10 kΩ or higher
Except retract position Below 1 Ω


If the result is not as specified, replace the outer mirror switch assembly.



c.

Check the mirror select and surface adjust switch. (for LHD, w/ Automatic Retractable Mirror)

i.
B364153C19
2.031,0.979 2.031,0.281 2.031,0.281 2.219,0.281 false 0.5,4.083 1,3.583 false 0.948,4.094 1.396,3.583 false 1.25,4.083 1.583,3.583 false 1.583,4.083 1.771,3.583 false 1.917,4.083 1.979,3.583 false 2.167,4.083 2.167,3.583 false 2.604,4.083 2.563,3.583 false 2.563,3.198 2.583,2.635 false 1,3.208 0.979,2.635 false 0.823,3.219 0.542,2.74 false 1.167,0.938 1.167,0.333 1.167,0.333 1.354,0.333 false 0.177,2.26 0.49,2.417 0.313,0.156 10 false *c 2.292,0.208 2.604,0.365 0.313,0.156 10 false *a 0.792,4.115 1.104,4.271 0.313,0.156 10 false M+ 0.375,4.115 0.688,4.271 0.313,0.156 10 false E 1.115,4.146 1.427,4.302 0.313,0.156 10 false VR 1.5,4.146 1.813,4.302 0.313,0.156 10 false HR 1.833,4.146 2.146,4.302 0.313,0.156 10 false VL 2.104,4.146 2.417,4.302 0.313,0.156 10 false HL 2.604,4.146 2.917,4.302 0.313,0.156 10 false B 2.49,2.469 2.802,2.625 0.313,0.156 10 false MR 0.844,2.458 1.156,2.615 0.313,0.156 10 false MAT 0.427,2.573 0.74,2.729 0.313,0.156 10 false E 1.406,0.25 1.719,0.406 0.313,0.156 10 false *b
*a Mirror Select and Surface Adjust Switch
*b Retractable Outer Mirror Switch
*c Component without harness connected
(Outer Mirror Switch Assembly)


Turn the mirror select and surface adjust switch to the L position.


ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (for left side):
Tester Connection Condition Specified Condition
10 (VL) - 7 (B)
13 (M+) - 15 (E)
Up Below 2 Ω
Off 10 kΩ or higher
10 (VL) - 15 (E)
13 (M+) - 7 (B)
Down Below 2 Ω
Off 10 kΩ or higher
9 (HL) - 7 (B)
13 (M+) - 15 (E)
Left Below 2 Ω
Off 10 kΩ or higher
9 (HL) - 15 (E)
13 (M+) - 7 (B)
Right Below 2 Ω
Off 10 kΩ or higher



iii.

Turn the mirror select and surface adjust switch to the R position.


iv.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (for right side):
Tester Connection Condition Specified Condition
12 (VR) - 7 (B)
13 (M+) - 15 (E)
Up Below 2 Ω
Off 10 kΩ or higher
12 (VR) - 15 (E)
13 (M+) - 7 (B)
Down Below 2 Ω
Off 10 kΩ or higher
11 (HR) - 7 (B)
13 (M+) - 15 (E)
Left Below 2 Ω
Off 10 kΩ or higher
11 (HR) - 15 (E)
13 (M+) - 7 (B)
Right Below 2 Ω
Off 10 kΩ or higher



v.

Check the mirror retract switch.


vi.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
4 (MAT) - 5 (E) AUTO position Below 35 Ω
Except AUTO position 10 kΩ or higher
2 (MR) - 5 (E) Retract position Below 35 Ω
Except retract position 10 kΩ or higher


If the result is not as specified, replace the outer mirror switch assembly.



d.

Check the mirror select and surface adjust switch. (for LHD, w/o Power Retract Mirror)

i.
B364151C23
1.76,1 1.76,0.333 1.76,0.333 2.042,0.333 true 0.583,4.229 1.083,3.583 true 1.677,4.24 1.833,3.583 true 1.01,4.24 1.458,3.583 true 1.344,4.24 1.667,3.583 true 1.969,4.229 2.042,3.583 true 2.25,4.26 2.25,3.615 true 2.688,4.25 2.625,3.604 true 0.25,2.583 0.563,2.781 0.313,0.198 10 false *b 2.094,0.219 2.406,0.417 0.313,0.198 10 false *a 2.667,4.271 2.979,4.448 0.313,0.177 10 false B 2.188,4.281 2.5,4.458 0.313,0.177 10 false HL 1.917,4.281 2.229,4.458 0.313,0.177 10 false VL 1.594,4.281 1.844,4.458 0.25,0.177 10 false HR 1.26,4.281 1.51,4.458 0.25,0.177 10 false VR 0.927,4.26 1.177,4.438 0.25,0.177 10 false M+ 0.51,4.25 0.76,4.427 0.25,0.177 10 false E
*a Mirror Select and Surface Adjust Switch
*b Component without harness connected
(Outer Mirror Switch Assembly)


Turn the mirror select switch to the L position.


ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (for left side):
Tester Connection Condition Specified Condition
10 (VL) - 7 (B)
13 (M+) - 15 (E)
Up Below 2 Ω
Off 10 kΩ or higher
10 (VL) - 15 (E)
13 (M+) - 7 (B)
Down Below 2 Ω
Off 10 kΩ or higher
9 (HL) - 7 (B)
13 (M+) - 15 (E)
Left Below 2 Ω
Off 10 kΩ or higher
9 (HL) - 15 (E)
13 (M+) - 7 (B)
Right Below 2 Ω
Off 10 kΩ or higher



iii.

Turn the mirror select switch to the R position.


iv.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (for right side):
Tester Connection Condition Specified Condition
12 (VR) - 7 (B)
13 (M+) - 15 (E)
Up Below 2 Ω
Off 10 kΩ or higher
12 (VR) - 15 (E)
13 (M+) - 7 (B)
Down Below 2 Ω
Off 10 kΩ or higher
11 (HR) - 7 (B)
13 (M+) - 15 (E)
Left Below 2 Ω
Off 10 kΩ or higher
11 (HR) - 15 (E)
13 (M+) - 7 (B)
Right Below 2 Ω
Off 10 kΩ or higher


If the result is not as specified, replace the outer mirror switch assembly.



e.

Check that the LED illuminates. (for LHD)

i.
B504694C01
0.906,1.823 1.083,1.271 true 2.396,1.792 2.271,1.271 true 0.146,0.292 0.458,0.49 0.313,0.198 10 false *a 0.813,1.833 1.427,2.031 0.615,0.198 10 false ILL- 2.344,1.823 2.958,2.021 0.615,0.198 10 false ILL+
*a Component without harness connected
(Outer Mirror Switch Assembly)


Apply battery voltage to the outer mirror switch assembly and check that the LED illuminates.

OK:
Battery Connection Specified Condition
Battery positive (+) - 8 (ILL+)
Battery negative (-) - 14 (ILL-)
LED illuminates


If the result is not as specified, replace the outer mirror switch assembly.



f.

Check the mirror select and surface adjust switch. (for RHD, w/ Power Retract Mirror)

i.
B491093C01
1.396,0.979 1.396,0.396 1.396,0.396 1.146,0.396 true 2.156,0.948 2.156,0.406 2.156,0.406 2.406,0.406 true 2.75,3.219 2.917,2.552 true 2.552,3.219 2.552,2.583 true 2.5,4.167 2.167,3.583 true 2.167,4.167 1.969,3.583 true 1.833,4.167 1.781,3.583 true 1.5,4.167 1.583,3.583 true 1.177,4.156 1.396,3.573 true 0.833,4.167 1,3.583 true 0.5,4.167 0.802,3.583 true 0.396,4.177 0.708,4.375 0.313,0.198 10 false MR 0.781,4.177 0.938,4.375 0.156,0.198 10 false B 1.094,4.177 1.406,4.375 0.313,0.198 10 false HL 1.438,4.188 1.75,4.385 0.313,0.198 10 false VL 1.76,4.177 2.073,4.375 0.313,0.198 10 false HR 2.104,4.188 2.417,4.385 0.313,0.198 10 false VR 2.448,4.188 2.76,4.385 0.313,0.198 10 false M+ 2.448,2.385 2.76,2.583 0.313,0.198 10 false MF 2.896,2.365 3.052,2.563 0.156,0.198 10 false E 0.958,0.302 1.271,0.5 0.313,0.198 10 false *a 2.448,0.323 2.76,0.521 0.313,0.198 10 false *b 0.26,2.656 0.573,2.854 0.313,0.198 10 false *c
*a Mirror Select and Surface Adjust Switch
*b Retractable Outer Mirror Switch
*c Component without harness connected
(Outer Mirror Switch Assembly)


Turn the mirror select switch to the L position.


ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (for left side):
Tester Connection Condition Specified Condition
12 (VL) - 15 (B)
9 (M+) - 1 (E)
Up Below 2 Ω
Off 10 kΩ or higher
12 (VL) - 1 (E)
9 (M+) - 15 (B)
Down Below 2 Ω
Off 10 kΩ or higher
13 (HL) - 15 (B)
9 (M+) - 1 (E)
Left Below 2 Ω
Off 10 kΩ or higher
13 (HL) - 1 (E)
9 (M+) - 15 (B)
Right Below 2 Ω
Off 10 kΩ or higher



iii.

Turn the mirror select switch to the R position.


iv.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (for right side):
Tester Connection Condition Specified Condition
10 (VR) - 15 (B)
9 (M+) - 1 (E)
Up Below 2 Ω
Off 10 kΩ or higher
10 (VR) - 1 (E)
9 (M+) - 15 (B)
Down Below 2 Ω
Off 10 kΩ or higher
11 (HR) - 15 (B)
9 (M+) - 1 (E)
Left Below 2 Ω
Off 10 kΩ or higher
11 (HR) - 1 (E)
9 (M+) - 15 (B)
Right Below 2 Ω
Off 10 kΩ or higher


If the result is not as specified, replace the outer mirror switch assembly.



g.

Check the mirror retract switch. (for RHD, w/ Power Retract Mirror)

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
2 (MF) - 1 (E) Extend position 10 kΩ or higher
Except extend position Below 1 Ω
16 (MR) - 1 (E) Retract position 10 kΩ or higher
Except retract position Below 1 Ω


If the result is not as specified, replace the outer mirror switch assembly.



h.

Check the mirror select and surface adjust switch. (for RHD, w/o Power Retract Mirror)

i.
B364151C24
1.76,1 1.76,0.333 1.76,0.333 2.042,0.333 true 0.583,4.229 1.083,3.583 true 1.677,4.24 1.833,3.583 true 1.01,4.24 1.458,3.583 true 1.344,4.24 1.667,3.583 true 1.969,4.229 2.042,3.583 true 2.25,4.24 2.25,3.594 true 2.688,4.229 2.625,3.583 true 0.344,2.583 0.656,2.781 0.313,0.198 10 false *b 2.094,0.219 2.406,0.417 0.313,0.198 10 false *a 0.531,4.25 0.844,4.427 0.313,0.177 10 false B 0.927,4.26 1.24,4.438 0.313,0.177 10 false HL 1.271,4.271 1.583,4.448 0.313,0.177 10 false VL 1.594,4.281 1.844,4.458 0.25,0.177 10 false HR 1.875,4.281 2.125,4.458 0.25,0.177 10 false VR 2.167,4.281 2.417,4.458 0.25,0.177 10 false M+ 2.667,4.281 2.917,4.458 0.25,0.177 10 false E
*a Mirror Select and Surface Adjust Switch
*b Component without harness connected
(Outer Mirror Switch Assembly)


Turn the mirror select switch to the L position.


ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (for left side):
Tester Connection Condition Specified Condition
12 (VL) - 15 (B)
9 (M+) - 7 (E)
Up Below 2 Ω
Off 10 kΩ or higher
12 (VL) - 7 (E)
9 (M+) - 15 (B)
Down Below 2 Ω
Off 10 kΩ or higher
13 (HL) - 15 (B)
9 (M+) - 7 (E)
Left Below 2 Ω
Off 10 kΩ or higher
13 (HL) - 7 (E)
9 (M+) - 15 (B)
Right Below 2 Ω
Off 10 kΩ or higher



iii.

Turn the mirror select switch to the R position.


iv.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (for right side):
Tester Connection Condition Specified Condition
10 (VR) - 15 (B)
9 (M+) - 7 (E)
Up Below 2 Ω
Off 10 kΩ or higher
10 (VR) - 7 (E)
9 (M+) - 15 (B)
Down Below 2 Ω
Off 10 kΩ or higher
11 (HR) - 15 (B)
9 (M+) - 7 (E)
Left Below 2 Ω
Off 10 kΩ or higher
11 (HR) - 7 (E)
9 (M+) - 15 (B)
Right Below 2 Ω
Off 10 kΩ or higher


If the result is not as specified, replace the outer mirror switch assembly.



i.

Check that the LED illuminates. (for RHD)

i.
B504694C03
0.938,1.854 1.104,1.281 true 2.479,1.823 2.292,1.281 true 0.167,0.271 0.479,0.469 0.313,0.198 10 false *a 0.792,1.854 1.406,2.052 0.615,0.198 10 false ILL+ 2.427,1.844 3.042,2.042 0.615,0.198 10 false ILL-
*a Component without harness connected
(Outer Mirror Switch Assembly)


Apply battery voltage to the outer mirror switch assembly and check that the LED illuminates.

OK:
Battery Connection Specified Condition
Battery positive (+) - 14 (ILL+)
Battery negative (-) - 8 (ILL-)
LED illuminates