Home › Vehicle Exterior › WINDOW / GLASS › RELAY › from 2018.04
RM33A0E _59 Vehicle Exterior _065390 WINDOW / GLASS _0328612 RELAY G

WINDOW / GLASS  RELAY  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 85912 1.INSPECT DEF RELAY

a.
E223161

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 4 Battery voltage applied between terminals 1 and 2 10 kΩ or higher
3 - 4 Battery voltage not applied between terminals Below 1 Ω
3 - 5 Battery voltage applied between terminals 1 and 2 Below 1 Ω
3 - 5 Battery voltage not applied between terminals 10 kΩ or higher
4 - 5 Always 10 kΩ or higher


If the result is not as specified, replace the DEF relay.


Hide 84794A 2.INSPECT DEICER RELAY

a.
B319589

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage applied between terminals 1 and 2 Below 1 Ω
3 - 5 Battery voltage not applied between terminals 10 kΩ or higher


If the result is not as specified, replace the deicer relay.


Hide 85912H 3.INSPECT HWD NO. 1 RELAY

a.
B429954

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage applied between terminals 1 and 2 Below 1 Ω
3 - 5 Battery voltage not applied between terminals 10 kΩ or higher


If the result is not as specified, replace the HWD NO. 1 relay.


Hide 85912J 4.INSPECT HWD NO. 2 RELAY

a.
B429954

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage applied between terminals 1 and 2 Below 1 Ω
3 - 5 Battery voltage not applied between terminals 10 kΩ or higher


If the result is not as specified, replace the HWD NO. 2 relay.


Hide 85912P 5.INSPECT HWD NO. 3 RELAY

a.
B319589

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage applied between terminals 1 and 2 Below 1 Ω
3 - 5 Battery voltage not applied between terminals 10 kΩ or higher


If the result is not as specified, replace the HWD NO. 3 relay.