85912
1.INSPECT DEF RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 4 | Battery voltage applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 4 | Battery voltage not applied between terminals | Below 1 Ω |
| 3 - 5 | Battery voltage applied between terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | Battery voltage not applied between terminals | 10 kΩ or higher |
| 4 - 5 | Always | 10 kΩ or higher |
If the result is not as specified, replace the DEF relay.
84794A
2.INSPECT DEICER RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage applied between terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | Battery voltage not applied between terminals | 10 kΩ or higher |
If the result is not as specified, replace the deicer relay.
85912H
3.INSPECT HWD NO. 1 RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage applied between terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | Battery voltage not applied between terminals | 10 kΩ or higher |
If the result is not as specified, replace the HWD NO. 1 relay.
85912J
4.INSPECT HWD NO. 2 RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage applied between terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | Battery voltage not applied between terminals | 10 kΩ or higher |
If the result is not as specified, replace the HWD NO. 2 relay.
85912P
5.INSPECT HWD NO. 3 RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage applied between terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | Battery voltage not applied between terminals | 10 kΩ or higher |