Home › General › SPECIFICATIONS › 6AR-FSE BATTERY / CHARGING › 2018.04–2021.02
RM33A0E _V1 General _065355 SPECIFICATIONS _0351559 6AR-FSE BATTERY / CHARGING F

SPECIFICATIONS  6AR-FSE BATTERY / CHARGING  SERVICE DATA  


Battery Standard specific gravity 1.25 or higher at 20°C (68°F)
Standard voltage 12.3 V or higher
Fuse Standard resistance Below 1 Ω
Charging circuit without load Standard current 10 A or more
Standard voltage 13.5 to 14.4 V
Charging circuit with load Standard current 30 A or more

Generator regulator assembly
Brush length Standard exposed brush length 9.5 to 11.5 mm (0.374 to 0.453 in.)
Minimum exposed brush length 4.5 mm (0.177 in.)

Generator rotor assembly
Tester Connection Condition Specified Condition
Slip ring - Slip ring Approx. 20°C (68°F) 1.8 to 2.2 Ω
Slip ring - Rotor Always 1 MΩ or higher

Slip ring diameter Standard diameter 14.2 to 14.8 mm (0.559 to 0.583 in.)
Minimum diameter 14 mm (0.551 in.)