DATA LIST
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus:
for Air Conditioner: Body Electrical / Air Conditioner / Data List.
for Engine: Powertrain / Engine / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Room Temperature Sensor | Cooler (room temp. sensor) thermistor | Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F) |
Actual cabin temperature displayed | Cooler (room temp. sensor) thermistor circuit malfunction
·
When open circuit: -6.50°C (20.30°F) ·
When short circuit: 57.25°C (135.05°F) |
| Ambient Temp Sensor | Thermistor assembly | Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F) |
Actual ambient temperature displayed | Thermistor assembly circuit malfunction
·
When open circuit: -23.30°C (-9.94°F) ·
When short circuit: 65.95°C (150.71°F) |
| Adjusted Ambient Temp | Adjusted ambient temperature | Min.: -30.80°C (-23.44°F)
Max.: 50.80°C (123.44°F) |
Adjust ambient temperature displayed | Air conditioning amplifier assembly malfunction |
| Evaporator Fin Thermistor | No. 1 cooler thermistor | Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | No. 1 cooler thermistor circuit malfunction
·
When open circuit: -29.70°C (-21.46°F) ·
When short circuit: 59.55°C (139.19°F) |
| Evaporator Target Temp | Evaporator target temperature | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Evaporator target temperature displayed | No. 1 cooler thermistor circuit malfunction
·
When open circuit: -327.68°C (-557.82°F) ·
When short circuit: 327.67°C (621.81°F) |
| Solar Sensor (D Side) | Driver side automatic light control sensor | Min.: 0
Max.: 255 |
Driver side automatic light control sensor value increases as brightness increases | Driver side automatic light control sensor circuit malfunction
·
When open circuit: 0 ·
When short circuit: 255 |
| Solar Sensor (P Side) | Front passenger side automatic light control sensor | Min.: 0
Max.: 255 |
Front passenger side automatic light control sensor value increases as brightness increases | Front passenger side automatic light control sensor circuit malfunction
·
When open circuit: 0 ·
When short circuit: 255 |
| Engine Coolant Temp | Engine coolant temperature sensor | Min.: 1.30°C (34.34°F)
Max.: 90.55°C (194.99°F) |
Actual engine coolant temperature displayed | ·
SFI system malfunction ·
CAN communication system malfunction |
| Blower Motor Speed Level | Blower motor speed level | Min.: 0
Max.: 31 |
Displayed speed level increases in range between 0 and 31 as blower motor speed increases | Blower motor with fan sub-assembly circuit malfunction |
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -0.4566 MPaG
Max.: 3.2943 MPaG |
Actual refrigerant pressure displayed | ·
Refrigerant line (gas leak etc.) ·
Air conditioner pressure sensor circuit malfunction |
| Regulator Control Current | Solenoid valve control current | Min.: 0 A
Max.: 0.997 A |
Value changes between 0 A and 0.997 A in accordance with solenoid valve operation | - |
| Air Outlet Servo Pulse (R) | No. 2 air conditioning radiator damper servo sub-assembly target pulse | Min.: 128
Max.: 383 |
·
FACE: 260 (pulse) ·
B/L: 212 (pulse) ·
FOOT: 182 (pulse) ·
F/D: 223 (pulse) ·
SHUT: 158 (pulse) ·
D/F: 177 (pulse) |
No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Air Outlet Servo Actual Pls(R) | No. 2 air conditioning radiator damper servo sub-assembly actual pulse | Min.: 128
Max.: 383 |
·
FACE: 260 (pulse) ·
B/L: 212 (pulse) ·
FOOT: 182 (pulse) ·
F/D: 223 (pulse) ·
SHUT: 158 (pulse) ·
D/F: 177 (pulse) |
No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Air Mix Servo Targ Pulse(R) | No. 3 air conditioning radiator damper servo sub-assembly target pulse | Min.: 128
Max.: 383 |
·
MAX COLD: 257 (pulse) ·
MAX HOT: 165 (pulse) |
·
No. 3 air conditioning radiator damper servo sub-assembly circuit malfunction ·
*1 |
| Air Mix Servo Actual Pulse(R) | No. 3 air conditioning radiator damper servo sub-assembly actual pulse | Min.: 128
Max.: 383 |
·
MAX COLD: 257 (pulse) ·
MAX HOT: 165 (pulse) |
·
No. 3 air conditioning radiator damper servo sub-assembly circuit malfunction ·
*1 |
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) target pulse | Min.: 128
Max.: 383 |
for LHD:
·
MAX COLD: 257 (pulse) ·
MAX HOT: 165 (pulse) for RHD:
·
MAX COLD: 255 (pulse) ·
MAX HOT: 347 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) circuit malfunction |
| Air Mix Servo Actual Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) actual pulse | Min.: 128
Max.: 383 |
for LHD:
·
MAX COLD: 257 (pulse) ·
MAX HOT: 165 (pulse) for RHD:
·
MAX COLD: 255 (pulse) ·
MAX HOT: 347 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) circuit malfunction |
| Air Mix Servo Targ Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) target pulse | Min.: 128
Max.: 383 |
for LHD:
·
MAX COLD: 255 (pulse) ·
MAX HOT: 347 (pulse) for RHD:
·
MAX COLD: 257 (pulse) ·
MAX HOT: 165 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) circuit malfunction |
| Air Mix Servo Actual Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) actual pulse | Min.: 128
Max.: 383 |
for LHD:
·
MAX COLD: 255 (pulse) ·
MAX HOT: 347 (pulse) for RHD:
·
MAX COLD: 257 (pulse) ·
MAX HOT: 165 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) circuit malfunction |
| Air Outlet Servo Pulse (D) | No. 1 air conditioning radiator damper servo sub-assembly (mode) target pulse | Min.: 128
Max.: 383 |
·
FACE-R: 241 (pulse) ·
FACE: 256 (pulse) ·
FACE1: 256 (pulse) ·
FACE2: 256 (pulse) ·
B/L: 267 (pulse) ·
B/L2: 267 (pulse) ·
FOOT-R: 297 (pulse) ·
FOOT: 297 (pulse) ·
FOOT-D: 305 (pulse) ·
FOOT-0: 288 (pulse) ·
F/D: 320 (pulse) ·
DEF-FOOT: 339 (pulse) ·
DEF or SHUT: 348 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly (mode) circuit malfunction |
| Air Outlet Servo Actu Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (mode) actual pulse | Min.: 128
Max.: 383 |
·
FACE-R: 241 (pulse) ·
FACE: 256 (pulse) ·
FACE1: 256 (pulse) ·
FACE2: 256 (pulse) ·
B/L: 267 (pulse) ·
B/L2: 267 (pulse) ·
FOOT-R: 297 (pulse) ·
FOOT: 297 (pulse) ·
FOOT-D: 305 (pulse) ·
FOOT-0: 288 (pulse) ·
F/D: 320 (pulse) ·
DEF-FOOT: 339 (pulse) ·
DEF or SHUT: 348 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly (mode) circuit malfunction |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly target pulse | Min.: 128
Max.: 383 |
for 2-tier Type:
·
Recirculation: 256 (pulse) ·
Fresh: 220 (pulse) for 1-tier Type:
·
Recirculation: 258 (pulse) ·
Fresh: 235 (pulse) |
No. 1 blower damper servo sub-assembly circuit malfunction |
| Air Inlet Damper Actual Pulse | No. 1 blower damper servo sub-assembly actual pulse | Min.: 128
Max.: 383 |
for 2-tier Type:
·
Recirculation: 256 (pulse) ·
Fresh: 220 (pulse) for 1-tier Type:
·
Recirculation: 258 (pulse) ·
Fresh: 235 (pulse) |
No. 1 blower damper servo sub-assembly circuit malfunction |
| Electric Heater Count | Maximum electric heater operation level | Min.: 0
Max.: 2 |
Maximum possible operation level of electric heater displayed | ·
PTC heater circuit malfunction ·
*4 |
| Electric Heater Active Level | Actual electric heater operation level | Min.: 0
Max.: 2 |
Actual operation level of electric heater displayed | ·
PTC heater circuit malfunction ·
*4 |
| Shift Set Temperature | Shift set temperature | 2C decr, 1C decr, Normal, 1C incr or 2C incr | Customized value displayed | - |
| Air Inlet Mode | Air inlet mode | Auto or Manual | Customized value displayed | - |
| Compressor Mode | Compressor mode | Auto or Manual | Customized value displayed | - |
| Evaporator Control | Evaporator control | Auto or Manual | Customized value displayed | - |
| ECO MODE Cancel | ECO mode cancel | OFF or ON | Customized value displayed | *2 |
| ECO Switch | ECO switch assembly (electric parking brake switch assembly) | OFF or ON | OFF: ECO switch assembly (electric parking brake switch assembly) not pushed
ON: ECO switch assembly (electric parking brake switch assembly) pushed and held |
·
ECO switch assembly (electric parking brake switch assembly) circuit malfunction ·
*2 |
| Refrigerant Shortage Check | Refrigerant shortage check | ON or OFF | Customized value displayed | - |
| Fan speed increment control | Fan speed increment control | Slow, Normal or Fast | Customized value displayed | - |
| Foot/DEF Auto Mode | Foot/defroster auto mode | ON or OFF | Customized value displayed | - |
| Foot/DEF Auto Blow Up | Foot/defroster auto blower speed increase | ON or OFF | Customized value displayed | - |
| Ambient Temperature Shift | Ambient temperature shift | 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr or 3C incr | Customized value displayed | - |
| A/C Cutoff Signal | A/C control cutoff signal | OFF or ON | The ECM sends the air conditioning control cutoff signal displayed | - |
| Ion Generate Control | Ion generator cancel | ON or OFF | Customized value displayed | *3 |
| Refrigerant Gas Type | Refrigerant gas type | R134a or R1234yf | Refrigerant gas type displayed | - |
| Set Temperature (D Side) | Driver side set temperature | Min.: MAX COLD
Max.: MAX HOT |
Driver side set temperature displayed | - |
| Set Temperature (P Side) | Front passenger side set temperature | Min.: MAX COLD
Max.: MAX HOT |
Front passenger side set temperature displayed | - |
| Set Temperature (Rear) | Rear side set temperature | Min.: MAX COLD
Max.: MAX HOT |
Rear side set temperature displayed | *1 |
| Outside Air Mode Auto Switch Function | Outside air mode auto switch function | ON or OFF | Customized value displayed | - |
| Number of Trouble Codes | Number of trouble codes | Min.: 0
Max.: 255 |
Number of DTCs displayed | - |
| Refrigerant High Pressure History | Refrigerant high pressure history | Min.: 0
Max.: 255 |
Number of times refrigerant high pressure history stored displayed | *5 |
*1: for 3 Zone Type
*2: w/ ECO Switch
*3: w/ Ion Generator
*4: w/ Quick Heater
*5: Refer to the following procedure to clear the refrigerant high pressure history.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Coolant Temperature | Engine coolant temperature | Min.: -40°C (-40°F)
Max.: 140°C (284°F) |
75 to 100°C (167 to 212°F): After warming up | This is the engine coolant temperature.
|
ACTIVE TEST
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower motor with fan sub-assembly | Min.: 0
Max.: 31 |
- |
| Magnetic Clutch Relay | Air conditioning system operation | OFF or ON | - |
| Defogger Relay (Rear) | Rear window defogger | OFF or ON | - |
| Heater Active Level | Quick heater assembly | Min.: 0
Max.: 2 |
*1 |
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 165 to 257 pulses for RHD:
Operates between 255 to 347 pulses |
| Air Mix Servo Targ Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 255 to 347 pulses for RHD:
Operates between 165 to 257 pulses |
| Air Outlet Servo Pulse (D) | No. 1 air conditioning radiator damper servo sub-assembly (mode) pulse | Min.: 128
Max.: 383 |
Operates between 241 to 348 pulses |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
for 2-tier Type:
Operates between 220 to 256 pulses for 1-tier Type:
Operates between 235 to 258 pulses |
| Rear Air Mix Servo Targ Pulse | No. 3 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
·
Operates between 165 to 257 pulses ·
*2 |
| A/O Servo Pulse(Rr D) | No. 2 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 158 to 260 pulses |
| Ion Generator | Ion generator sub-assembly | OFF or ON | *3 |
*1: w/ Quick Heater
*2: for 3 Zone Type
*3: w/ Ion Generator