The air conditioning harness assembly connects the air conditioning amplifier assembly and the servo motors. The air conditioning amplifier assembly supplies power and sends operation instructions to each servo motor through the air conditioning harness assembly. Each servo motor sends damper position information to the air conditioning amplifier assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1497 | Communication Malfunction (Bus Ic) | Error or open in communication line | ·
Air conditioning harness assembly ·
No. 1 air conditioning radiator damper servo sub-assembly ·
No. 2 air conditioning radiator damper servo sub-assembly ·
No. 3 air conditioning radiator damper servo sub-assembly*1 ·
Air conditioning amplifier assembly |
Memorized
(10 sec. or more)*2 |
*1: for 3 Zone Type
*2: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 165 to 257 pulses for RHD:
Operates between 255 to 347 pulses |
| Rear Air Mix Servo Targ Pulse | No. 3 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
·
Operates between 165 to 257 pulses ·
* |
| A/O Servo Pulse(Rr D) | No. 2 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 158 to 260 pulses |
*: for 3 Zone Type
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(D) |
| Tester Display |
|---|
| Rear Air Mix Servo Targ Pulse |
| Tester Display |
|---|
| A/O Servo Pulse(Rr D) |
| Result | Proceed to |
|---|---|
| All of the damper servo motors are malfunctioning | A |
| One of the damper servo motors is malfunctioning | B |
A
B
Disconnect the No. 1 air conditioning radiator damper servo sub-assembly connector.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| A/O Servo Pulse(Rr D) | No. 2 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 158 to 260 pulses |
| Tester Display |
|---|
| A/O Servo Pulse(Rr D) |
The damper servo motor operates smoothly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
When inspecting the air conditioning amplifier assembly, do not bring the tester probes too close to each other as a short circuit may occur.
Disconnect the z11 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z11-2 (BUS G) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z11-4 (B BUS) - Body ground | Ignition switch ON | 11 to 14 V |
Turn the ignition switch to ON.
Using an oscilloscope, check the waveform.
| Item | Content |
|---|---|
| Terminal No. | z11-3 (BUS) - z11-2 (BUS G) |
| Tool Setting | 2 V/DIV., 2 ms./DIV. |
| Condition | Ignition switch ON |
Waveform is similar to that shown in the illustration.
The waveform varies with the blower speed.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 165 to 257 pulses for RHD:
Operates between 255 to 347 pulses |
| Rear Air Mix Servo Targ Pulse | No. 3 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
·
Operates between 165 to 257 pulses ·
* |
| A/O Servo Pulse(Rr D) | No. 2 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 158 to 260 pulses |
*: for 3 Zone Type
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(D) |
| Tester Display |
|---|
| Rear Air Mix Servo Targ Pulse |
| Tester Display |
|---|
| A/O Servo Pulse(Rr D) |
| Result | Proceed to |
|---|---|
| Only the No. 1 air conditioning radiator damper servo sub-assembly does not operate | A |
| Only the No. 2 air conditioning radiator damper servo sub-assembly does not operate | B |
| Only the No. 3 air conditioning radiator damper servo sub-assembly does not operate | |
| Only the No. 3 air conditioning radiator damper servo sub-assembly operates |
A
B
Disconnect the z11 air conditioning amplifier assembly connector.
Disconnect the No. 1 air conditioning radiator damper servo sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z11-2 (BUS G) - A-3 (GND) | Always | Below 1 Ω |
| z11-3 (BUS) - A-2 (LIN) | Always | Below 1 Ω |
| z11-4 (B BUS) - A-1 (+B) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG