Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) › from 2018.04
RM33A0E _58 Vehicle Interior _065387 HEATING / AIR CONDITIONING _0341905 AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)  B1497  Communication Malfunction (Bus Ic)  


DESCRIPTION

The air conditioning harness assembly connects the air conditioning amplifier assembly and the servo motors. The air conditioning amplifier assembly supplies power and sends operation instructions to each servo motor through the air conditioning harness assembly. Each servo motor sends damper position information to the air conditioning amplifier assembly.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B1497 Communication Malfunction (Bus Ic) Error or open in communication line
·

Air conditioning harness assembly

·

No. 1 air conditioning radiator damper servo sub-assembly

·

No. 2 air conditioning radiator damper servo sub-assembly

·

Air conditioning amplifier assembly


Memorized
(10 sec. or more)*

*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.


WIRING DIAGRAM

E387931E02
5.542,0.479 6.313,0.677 0.771,0.198 10 false B BUS 5.542,0.896 6.313,1.094 0.771,0.198 10 false BUS 5.542,1.333 6.313,1.531 0.771,0.198 10 false BUS G 5.354,0.479 5.531,0.677 0.177,0.198 10 false 4 5.354,0.885 5.594,1.094 0.24,0.208 10 false 3 5.354,1.333 5.594,1.542 0.24,0.208 10 false 2 6.615,0.427 6.833,0.625 0.219,0.198 10 false +B 6.76,1.021 7,1.229 0.24,0.208 10 false IC 3,0.552 3.219,0.75 0.219,0.198 10 false +B 2.979,1.021 3.198,1.219 0.219,0.198 10 false LIN 2.906,1.438 3.229,1.635 0.323,0.198 10 false GND 3.292,0.469 3.531,0.677 0.24,0.208 10 false 1 3.302,0.854 3.542,1.063 0.24,0.208 10 false 2 3.302,1.333 3.542,1.542 0.24,0.208 10 false 3 1.208,1.583 1.75,1.792 0.542,0.208 10 false Air Mix 1.281,3.5 1.688,3.698 0.406,0.198 10 false Mode 5.521,2.146 7.073,2.573 1.552,0.427 10 false Air Conditioning Amplifier Assembly 5.521,1.969 5.833,2.156 0.313,0.188 10 false z11 5.229,4.229 7.125,4.604 1.896,0.375 10 false No. 2 Air Conditioning Radiator Damper Servo Sub-assembly 0.375,4.604 0.583,4.781 0.208,0.177 10 false A 0.375,4.76 3.167,5.115 2.792,0.354 10 false No. 1 Air Conditioning Radiator Damper Servo Sub-assembly 0.823,5.354 2.458,5.542 1.635,0.188 10 false : LIN Communication Line 3.635,4.625 5.156,5 1.521,0.375 10 false Air Conditioning Harness Assembly

PROCEDURE

1.PERFORM ACTIVE TEST USING GTS
a.

Disconnect the No. 1 air conditioning radiator damper servo sub-assembly connector.


b.

Connect the GTS to the DLC3.


c.

Turn the ignition switch to ON.


d.

Turn the GTS on.


e.

Enter the following menus: Body Electrical / Air Conditioner / Active test.


f.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air mix) pulse Min.: 128
Max.: 383
for LHD:

Operates between 165 to 257 pulses


for RHD:

Operates between 255 to 347 pulses


A/O Servo Pulse(Rr D) No. 2 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 158 to 260 pulses
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(D)
50004 121 24
Body Electrical > Air Conditioner > Active Test
Tester Display
A/O Servo Pulse(Rr D)
50004 121 56

Result:
Result Proceed to
All of the damper servo motors are malfunctioning A
One of the damper servo motors is malfunctioning B



A

2.PERFORM ACTIVE TEST USING GTS

B

4.PERFORM ACTIVE TEST USING GTS
2.PERFORM ACTIVE TEST USING GTS
a.

Disconnect the No. 1 air conditioning radiator damper servo sub-assembly connector.


b.

Connect the GTS to the DLC3.


c.

Turn the ignition switch to ON.


d.

Turn the GTS on.


e.

Enter the following menus: Body Electrical / Air Conditioner / Active test.


f.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
A/O Servo Pulse(Rr D) No. 2 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 158 to 260 pulses
Body Electrical > Air Conditioner > Active Test
Tester Display
A/O Servo Pulse(Rr D)
50004 121 56
OK:

The damper servo motor operates smoothly.



Result:
Proceed to
OK
NG



OK

REPLACE NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

NG

3.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY
3.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY
E334625C27
2.802,0.333 3.135,0.542 0.333,0.208 2.979,1.26 2.26,2.073 true 3.094,1.271 2.688,2.24 true 2.906,1.188 1.917,0.573 true 0.198,0.135 0.51,0.333 0.313,0.198 10 false *a 1.948,2.094 2.406,2.292 0.458,0.198 10 false BUS 2.406,2.271 3.021,2.521 0.615,0.25 10 false BUS G 0.417,3.938 0.875,4.135 0.458,0.198 10 false GND 2.865,0.354 3.177,0.552 0.313,0.198 10 false z11 1.677,0.385 2.177,0.625 0.5,0.24 10 false B BUS
*a Component with harness connected
(Air Conditioning Amplifier Assembly)


NOTICE:

When inspecting the air conditioning amplifier assembly, do not bring the tester probes too close to each other as a short circuit may occur.


a.

Disconnect the z11 air conditioning amplifier assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
z11-2 (BUS G) - Body ground Always Below 1 Ω



c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
z11-4 (B BUS) - Body ground Ignition switch ON 11 to 14 V



d.

Turn the ignition switch to ON.


e.

Using an oscilloscope, check the waveform.

Item Content
Terminal No. z11-3 (BUS) - z11-2 (BUS G)
Tool Setting 2 V/DIV., 2 ms./DIV.
Condition Ignition switch ON

OK:

Waveform is similar to that shown in the illustration.


HINT:

The waveform varies with the blower speed.



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING HARNESS ASSEMBLY

NG

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

4.PERFORM ACTIVE TEST USING GTS
a.

Disconnect the No. 1 air conditioning radiator damper servo sub-assembly connector.


b.

Connect the GTS to the DLC3.


c.

Turn the ignition switch to ON.


d.

Turn the GTS on.


e.

Enter the following menus: Body Electrical / Air Conditioner / Active test.


f.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air mix) pulse Min.: 128
Max.: 383
for LHD:

Operates between 165 to 257 pulses


for RHD:

Operates between 255 to 347 pulses


A/O Servo Pulse(Rr D) No. 2 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 158 to 260 pulses
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(D)
50004 121 24
Body Electrical > Air Conditioner > Active Test
Tester Display
A/O Servo Pulse(Rr D)
50004 121 56

Result:
Result Proceed to
Only the No. 1 air conditioning radiator damper servo sub-assembly does not operate A
Only the No. 2 air conditioning radiator damper servo sub-assembly does not operate B



A

5.INSPECT AIR CONDITIONING HARNESS ASSEMBLY (AIR CONDITIONING AMPLIFIER ASSEMBLY - NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY)

B

REPLACE AIR CONDITIONING HARNESS ASSEMBLY

5.INSPECT AIR CONDITIONING HARNESS ASSEMBLY (AIR CONDITIONING AMPLIFIER ASSEMBLY - NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY)
a.

Disconnect the z11 air conditioning amplifier assembly connector.


b.

Disconnect the No. 1 air conditioning radiator damper servo sub-assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
z11-2 (BUS G) - A-3 (GND) Always Below 1 Ω
z11-3 (BUS) - A-2 (LIN) Always Below 1 Ω
z11-4 (B BUS) - A-1 (+B) Always Below 1 Ω



Result:
Proceed to
OK
NG



OK

REPLACE NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

NG

REPLACE AIR CONDITIONING HARNESS ASSEMBLY