Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) › 2020.02–2020.08
RM33A0E _58 Vehicle Interior _065387 HEATING / AIR CONDITIONING _0341905 AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) J

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)  Cooling is Poor  


DESCRIPTION

If the cooling effect of the air conditioning system is weak, the following factors may be the cause.

Symptom Factor
·

Cooling effectiveness is poor

·

Cooling response is slow


·

Compressor assembly with pulley (compressor solenoid) malfunction*1

·

Cooler compressor assembly (compressor solenoid) malfunction*2

·

Magnet clutch assembly malfunction*2

·

Air conditioning amplifier assembly malfunction

·

Refrigerant volume (high)

·

Refrigerant volume (low)

·

Clogged cooler condenser assembly fins

·

Cooling fan system malfunction

·

Mechanical locking of damper and damper link

·

High inlet air temperature



*1: for 2AR-FE, A25A-FKS

*2: for 6AR-FSE


PROCEDURE

1.PERFORM REFRIGERANT SHORTAGE CHECK
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.

Body Electrical > Air Conditioner > Utility
Tester Display
Refrigerant Gas Volume Check
50005 121 2186

e.

Check that the following conditions are met and perform the refrigerant shortage check according to the display on the GTS.

Measurement Condition:
Item Condition
A/C switch On
Ambient temperature* 0 to 49°C (32 to 120°F)
Blower speed HI

*: If the ambient temperature is not within the range shown, do not perform this check.


Result:
Result Amount of Refrigerant
Refrigerant correct Correct
Refrigerant shortage Insufficient


OK:

"Refrigerant correct" is displayed on the GTS.


Result:
Proceed to
OK
NG



OK

2.PERFORM ACTIVE TEST USING GTS

NG

2.PERFORM ACTIVE TEST USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active Test.


e.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air mix) pulse Min.: 128
Max.: 383
for LHD:

Operates between 165 to 257 pulses


for RHD:

Operates between 255 to 347 pulses


Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(D)
50004 121 24
OK:

The No. 1 air conditioning radiator damper servo sub-assembly operates.



Result:
Proceed to
OK
NG



OK

INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET

NG