Home › Engine / Hybrid System › M20A-FKS (COOLING) › FLOW SHUTTING VALVE (for Heater) › from 2021.02
RM33A0E _51 Engine / Hybrid System _098633 M20A-FKS COOLING _0461856 FLOW SHUTTING VALVE(for Heater) A

M20A-FKS COOLING  FLOW SHUTTING VALVE(for Heater)  REMOVAL  


PROCEDURE

Hide 1.DRAIN ENGINE COOLANT

Hide 16260 2.REMOVE FLOW SHUTTING VALVE (WATER BY-PASS HOSE ASSEMBLY)

a.
A443815

Disconnect the flow shutting valve (water by-pass hose assembly) connector.


b.

Disconnect the inlet heater hose connector from the flow shutting valve (water by-pass hose assembly).

NOTICE:

Remove any foreign matter on the flow shutting valve (water by-pass hose assembly) and inlet heater hose connector before performing this work.


i.
A443816C01
1.51,1.354 1.51,1.667 true 1.448,1.698 1.635,1.885 0.188,0.188 10 true *a
*a Retainer
V100135

Pull out
V100136

Pull off


Pull out the retainer to disengage the lock claws and pull off the inlet heater hose connector.


ii.

Check that there is no foreign matter on the sealing surfaces of the disconnected water lines. Clean them if necessary.


iii.

Cover the disconnected inlet heater hose connector with a plastic bag to prevent damage and contamination.



c.
A443818

Disengage the clamp to disconnect the vacuum hose from the flow shutting valve (water by-pass hose assembly).


d.
A443819

Slide the clip and disconnect the flow shutting valve (water by-pass hose assembly) from the No. 1 water by-pass pipe sub-assembly.


e.

Remove the bolt and the flow shutting valve (water by-pass hose assembly).