1.DRAIN ENGINE COOLANT
16260
2.REMOVE FLOW SHUTTING VALVE (WATER BY-PASS HOSE ASSEMBLY)
Disconnect the flow shutting valve (water by-pass hose assembly) connector.
Disconnect the inlet heater hose connector from the flow shutting valve (water by-pass hose assembly).
Remove any foreign matter on the flow shutting valve (water by-pass hose assembly) and inlet heater hose connector before performing this work.
| *a | Retainer |
|
Pull out |
|
Pull off |
Pull out the retainer to disengage the lock claws and pull off the inlet heater hose connector.
Check that there is no foreign matter on the sealing surfaces of the disconnected water lines. Clean them if necessary.
Cover the disconnected inlet heater hose connector with a plastic bag to prevent damage and contamination.
Disengage the clamp to disconnect the vacuum hose from the flow shutting valve (water by-pass hose assembly).
Slide the clip and disconnect the flow shutting valve (water by-pass hose assembly) from the No. 1 water by-pass pipe sub-assembly.
Remove the bolt and the flow shutting valve (water by-pass hose assembly).