Home › Engine / Hybrid System › M20A-FKS (COOLING) › FLOW SHUTTING VALVE (for CVT) › from 2021.02
RM33A0E _51 Engine / Hybrid System _098633 M20A-FKS COOLING _0461857 FLOW SHUTTING VALVE(for CVT) A

M20A-FKS COOLING  FLOW SHUTTING VALVE(for CVT)  REMOVAL  


PROCEDURE

Hide 1.DRAIN ENGINE COOLANT

Hide 2.REMOVE AIR CLEANER ASSEMBLY WITH AIR CLEANER HOSE

Hide 16264D 3.REMOVE FLOW SHUTTING VALVE (NO. 2 WATER BY-PASS HOSE)

a.
A443823

Disconnect the flow shutting valve (No. 2 water by-pass hose) connector.


b.
A443824

Slide the clip and disconnect the No. 4 water by-pass hose from the flow shutting valve (No. 2 water by-pass hose).


c.
A443826

Slide the clip and disconnect the flow shutting valve (No. 2 water by-pass hose) from the transmission oil cooler.


d.

Remove the bolt and the flow shutting valve (No. 2 water by-pass hose).