84330
1.INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY
| *a | Component without harness connected
(Hazard Warning Signal Switch Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 6 (TB) - 3 (E) | Hazard warning signal switch off | 10 kΩ or higher |
| Hazard warning signal switch on | Below 1 Ω |
If the result is not as specified, replace the hazard warning signal switch assembly.
Illumination Inspection
Apply battery voltage to the hazard warning signal switch assembly and check that the switch illuminates.
| Condition | Specified Condition |
|---|---|
| Battery positive (+) → Terminal 7 (ILL+)
Battery negative (-) → Terminal 2 (ILL-) |
Illuminates |
If the result is not as specified, replace the hazard warning signal switch assembly.