Home › Brake › PARKING BRAKE › ELECTRIC PARKING BRAKE SYSTEM › from 2021.02
RM33A0E _54 Brake _065369 PARKING BRAKE _0328504 ELECTRIC PARKING BRAKE SYSTEM C

PARKING BRAKE  ELECTRIC PARKING BRAKE SYSTEM  C061012  Right Electric Parking Brake Actuator Control Circuit Short to Battery  


DESCRIPTION

DTC No. Detection Item DTC Detection Condition Trouble Area Memory Note
C061012 Right Electric Parking Brake Actuator Control Circuit Short to Battery
·

Diagnosis Condition:

Electric parking brake not operating

·

Malfunction Status:

The ECU power supply is normal but there is a malfunction in the electric parking brake actuator RH internal circuit (short to +B).

·

Detection Time:

Approximately 0.015 to 0.195 seconds (depending on each malfunction)


·

Parking brake actuator assembly RH

·

No. 1 parking brake wire assembly

·

Wire harness or connector

·

Skid control ECU (brake actuator assembly)


DTC stored An electric parking brake system malfunction is displayed on the combination meter assembly.

PROCEDURE

1.CHECK FOR SHORT TO +B
a.

Turn the ignition switch off.


b.

Make sure the No. 1 parking brake wire assembly is securely installed.


c.

Disconnect the u1 parking brake actuator assembly RH connector.


d.
C401220C77
1.448,0.313 1.865,0.563 0.417,0.25 1,2.75 1.417,2 true 2.417,2.75 2,2 true 0.25,0.229 0.563,0.427 0.313,0.198 10 false *a 1.573,0.365 1.885,0.563 0.313,0.198 10 false u1 0.917,2.75 1.417,2.917 0.5,0.167 10 false RE- 2.333,2.75 2.833,2.927 0.5,0.177 10 false RE+
*a Front view of No. 1 Parking Brake Wire Assembly
(to Parking Brake Actuator Assembly RH)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
u1-2 (RE+) - u1-1 (RE-) Electric parking brake not operating Below 1 V



Result:
Proceed to
OK
NG



OK

REPLACE PARKING BRAKE ACTUATOR ASSEMBLY RH

NG

2.CHECK FOR SHORT TO +B
2.CHECK FOR SHORT TO +B
a.

Disconnect the uR2 No. 1 parking brake wire assembly connector.


b.
C402973C08
1.5,0.667 1.917,0.917 0.417,0.25 0.25,0.25 0.51,0.51 0.26,0.26 10 false *a 1.604,0.698 1.906,0.927 0.302,0.229 10 false uR2
*a Front view of wire harness connector
(to No. 1 Parking Brake Wire Assembly)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
uR2-2 - uR2-1 Electric parking brake not operating Below 1 V



Result:
Proceed to
OK
NG



OK

REPLACE NO. 1 PARKING BRAKE WIRE ASSEMBLY

NG

3.CHECK FOR SHORT TO +B
3.CHECK FOR SHORT TO +B
a.

Disconnect the uR2 No. 1 parking brake wire assembly connector.


b.

Disconnect the A34 skid control ECU (brake actuator assembly) connector.


c.

Measure the voltage according to the value(s) in the table below.

C403649C08
1.667,0.417 2.083,0.667 0.417,0.25 5.125,0.417 5.542,0.667 0.417,0.25 1.844,2.156 1.344,1.656 true 0.615,2.156 1.115,1.656 true 1.76,0.469 2.219,0.667 0.458,0.198 10 false A34 5.208,0.458 5.667,0.656 0.458,0.198 10 false uR2 0.5,0.75 0.958,1.031 0.458,0.281 10 false *b 0.167,0.167 0.583,0.417 0.417,0.25 10 false *a 4.583,0.75 5.125,0.948 0.542,0.198 10 false *c 1.698,2.198 2.198,2.448 0.5,0.25 10 false MRR- 0.438,2.198 0.938,2.448 0.5,0.25 10 false MRR+
*a Front view of wire harness connector *b to Skid Control ECU (Brake Actuator Assembly)
*c to No. 1 Parking Brake Wire Assembly - -


Standard Voltage:
Tester Connection Condition Specified Condition
uR2-2 or A34-2 (MRR+) - Body ground Always Below 1 V
uR2-1 or A34-3 (MRR-) - Body ground Always Below 1 V



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR