Home › General › SPECIFICATIONS › M20A-FKS STARTING › from 2021.02
RM33A0E _V1 General _065355 SPECIFICATIONS _0461644 M20A-FKS STARTING F

SPECIFICATIONS  M20A-FKS STARTING  SERVICE DATA  


Starter Assembly
Tester Connection Condition Specified Condition
Battery positive (+) terminal - Terminal 30 - Terminal 50 11.5 V Below 90 A

Magnet Starter Switch Assembly (for DENSO Made)
Tester Connection Condition Specified Condition
Terminal 50 -Magnet starter switch assembly body Always Below 2 Ω

Starter Armature Assembly (for DENSO Made)
Tester Connection Condition Specified Condition
Segment - Segment Always Below 1 Ω
Segment - Starter armature core 10 kΩ or higher

Commutator for runout Maximum Runout 0.05 mm (0.00197 in.)

Commutator diameter Standard Diameter 25.0 mm (0.984 in.)
Minimum Diameter 24.0 mm (0.945 in.)

Undercut depth Standard Undercut Depth 0.7 mm (0.0276 in.)
Minimum Undercut Depth 0.2 mm (0.00787 in.)

Starter Brush Holder Assembly (for DENSO Made)
Brush length Standard Length 11.6 mm (0.457 in.)
Minimum Length 7.6 mm (0.299 in.)

Engine Switch
Tester Connection Condition Specified Condition
5 (SS1) - 6 (AGND)
1 (SS2) - 6 (AGND)
Not pushed 10 kΩ or higher
Pushed Below 1 Ω

Condition Specified Condition
Battery positive (+) → Terminal 9 (SWIL)
Battery negative (-) → Terminal 6 (AGND)
Illuminates

Ignition or Starter Switch Assembly
Tester Connection Condition Specified Condition
Between all terminals LOCK 10 kΩ or higher
6 (ACC) - 7 (AM1) ACC Below 1 Ω
6 (ACC) - 7 (AM1) - 8 (IG1) ON Below 1 Ω
1 (AM2) - 2 (IG2)
5 (ST1) - 7 (AM1) - 8 (IG1) START Below 1 Ω
1 (AM2) - 2 (IG2) - 4 (ST2)

Starter Relay Assembly
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω