Home › General › SPECIFICATIONS › M20A-FKS BATTERY / CHARGING › from 2021.02
RM33A0E _V1 General _065355 SPECIFICATIONS _0461649 M20A-FKS BATTERY / CHARGING F

SPECIFICATIONS  M20A-FKS BATTERY / CHARGING  SERVICE DATA  


Battery Standard specific gravity 1.25 or higher at 20°C (68°F)
Standard voltage 12.3 V or higher at 20°C (68°F)
Fuse Standard resistance Below 1 Ω
Charging circuit without load Standard amperage 10 A or more
Standard voltage 13.2 to 14.8 V
Charging circuit with load Standard amperage 30 A or more

Generator brush holder assembly
Brush length Standard exposed brush length 9.5 to 11.5 mm (0.374 to 0.453 in.)
Minimum exposed brush length 4.5 mm (0.177 in.)

Generator rotor assembly
Generator Assembly Type Tester Connection Condition Specified Condition
for 100 A Type Slip ring - Slip ring 20°C (68°F) 1.8 to 2.2 Ω
for 130 A Type 2.3 to 2.7 Ω
- Slip ring - Rotor Always 10 MΩ or higher

Slip ring diameter Standard diameter 14.2 to 14.8 mm (0.559 to 0.583 in.)
Minimum diameter 14.0 mm (0.551 in.)