Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM
NM33C0E _51 Engine / Hybrid System _067713 HYBRID / BATTERY CONTROL _0330463 HYBRID CONTROL SYSTEM DE DETAILS F

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  DETAILS  INVERTER WITH CONVERTER  


CONSTRUCTION


a.

A compact, lightweight inverter with converter assembly, in which the MG ECU, inverter, boost converter and DC-DC converter are integrated, is used. The inverter and boost converter primarily consist of Intelligent Power Modules (IPMs), a reactor, and capacitor. The IPM is an integrated power module consisting of a signal processor, protective function processor, and Insulated Gate Bipolar Transistors (IGBTs).


b.

The inverter with converter assembly ensures heat dissipation through use of a water-cooled cooling system that is isolated from the engine cooling system.


c.

As a safety measure due to the use of high-voltage electricity, interlock switches are provided, which shut off the system main relays via the hybrid vehicle control ECU assembly when the inverter cover is removed or a high-voltage connector is disconnected.

W132054C01
0.906,1.375 1.25,1.594 0.344,0.219 11 false *1 0.906,2.365 1.25,2.583 0.344,0.219 11 false *2
*1 Boost Converter / Inverter *2 DC-DC Converter / Reactor
V100135

HV Coolant Outlet
V100136

HV Coolant Inlet



d.

The inverter uses the IPM to perform switching control. The IPMs for generator (MG1) and motor (MG2) each have a bridge circuit consisting of IGBTs. The IPM for generator (MG1) uses 6 IGBTs, one for each arm, and motor (MG2) uses 6 pairs of IGBTs, single in parallel for each arm.


e.

The boost converter uses a boost IPM to perform switching control, a reactor to act as an inductor, and a capacitor to accumulate and store electricity. The boost IPM uses IGBT2 for boosting voltage, and IGBT1 for reducing voltage.

W136964E02
0.75,2.167 1.083,2.167 1.083,2.167 1.167,1.583 true 3,4.333 3.417,3.917 3.417,3.917 3.583,3.917 true 3,1.583 3.417,1.167 3.417,1.167 3.583,1.167 true 2.667,7.365 3.25,7.948 3.25,7.948 3.417,7.948 true 2.667,2.271 3.5,2.271 true 0.667,7.667 0.833,7.667 0.833,7.667 1.833,7.365 true 2.667,6.875 3,7.125 3,7.125 3.167,7.125 true 0.667,6.531 0.833,6.531 0.833,6.531 1.833,6.865 true 0.365,1.208 0.823,1.406 0.458,0.198 10 false MG2 0.365,3.927 0.823,4.125 0.458,0.198 10 false MG1 0.271,1.917 0.74,2.583 0.469,0.667 10 false Inverter Current Sensor 3.635,3.802 4.625,4 0.99,0.198 10 false IPM for MG1 1.188,8.719 2.26,8.917 1.073,0.198 10 false Boost Converter 1.969,5.688 2.74,5.885 0.771,0.198 10 false Capacitor 3.177,3.115 3.948,3.313 0.771,0.198 10 false Inverter 1.49,7.49 2.406,7.688 0.917,0.198 10 false Boost IPM 1.594,8.031 2.365,8.229 0.771,0.198 10 false Reactor 3.24,9.177 5.563,9.563 2.323,0.385 10 false Inverter with Converter Assembly 4.042,5.99 4.958,6.188 0.917,0.198 10 false MG ECU 3.781,7.292 4.927,7.583 1.146,0.292 10 false DC-DC Converter 5.698,8.625 6.74,9.094 1.042,0.469 10 false Compressor with Motor Assembly 5.771,6.198 6.667,6.802 0.896,0.604 10 false Hybrid Vehicle Control ECU Assembly 2.25,9.448 3.167,9.646 0.917,0.198 10 false HV Battery 3.646,1.052 4.635,1.25 0.99,0.198 10 false IPM for MG2 3.552,2.188 4.542,2.385 0.99,0.198 10 false IGBT 1,1.385 1.156,1.583 0.156,0.198 10 false U 1,1.552 1.156,1.75 0.156,0.198 10 false V 0.979,1.208 1.135,1.406 0.156,0.198 10 false W 0.99,3.917 1.146,4.115 0.156,0.198 10 false W 1.01,4.083 1.167,4.281 0.156,0.198 10 false U 1.01,4.25 1.167,4.448 0.156,0.198 10 false V 3.448,7.865 4.438,8.063 0.99,0.198 10 false IGBT2 0.25,7.583 1.24,7.781 0.99,0.198 10 false IGBT1 0.26,6.448 1.25,6.646 0.99,0.198 10 false IGBT1 3.208,7.042 4.198,7.24 0.99,0.198 10 false IGBT2


f.

MG ECU

i.

The MG ECU is provided in the inverter with converter assembly. In accordance with the signals received from the hybrid vehicle control ECU assembly, the MG ECU controls the inverter and boost converter in order to drive generator (MG1) or motor (MG2) or cause them to generate electricity.


ii.

The MG ECU transmits information that is required for vehicle control, such as the atmospheric pressure, inverter temperature and any failure information, to the hybrid vehicle control ECU assembly. The MG ECU receives information that is required for controlling generator (MG1) and motor (MG2), such as the required motive force and the temperature of generator (MG1) and motor (MG2), from the hybrid vehicle control ECU assembly.



g.

Temperature Sensor for Inverter with Converter Assembly

i.

For the inverter with converter assembly, there are 4 different temperature sensors; one of them is located at the IPMs for motor (MG2), 2 of them are located at the boost converter, and the remaining sensor is located at the HV coolant passage.


ii.

These sensors detect the temperatures at areas inside the inverter with converter assembly, and transmit that temperature information to the hybrid vehicle control ECU assembly via the MG ECU. The hybrid vehicle control ECU assembly optimizes the cooling system according to the temperature information, maintaining the output performance of the inverter with converter assembly.

W136965E02
3.083,1.281 3.75,1.281 true 3.094,3.5 4.094,3.5 true 0.75,2 0.917,2 0.917,2 1.167,1.5 true 0.375,1.156 0.833,1.354 0.458,0.198 10 false MG2 0.385,3.771 0.844,3.969 0.458,0.198 10 false MG1 0.271,1.75 0.76,2.427 0.49,0.677 10 false Inverter Current Sensor 3.792,1.177 5.479,1.375 1.688,0.198 10 false IPM for MG2 4.135,3.396 5.823,3.594 1.688,0.198 10 false IPM for MG1 3.125,1.917 3.583,2.115 0.458,0.198 10 false *1 1.823,5.698 2.281,5.896 0.458,0.198 10 false *2 2.417,5.698 2.875,5.896 0.458,0.198 10 false *3 4.583,4.677 5.042,4.875 0.458,0.198 10 false *4 5.542,4.156 6.771,4.385 1.229,0.229 10 false HV Coolant Flow 3.5,7.5 4.573,7.698 1.073,0.198 10 false Boost Converter 3.5,0.385 4.271,0.583 0.771,0.198 10 false Inverter 5.667,5.271 7.021,5.781 1.354,0.51 10 false Hybrid Vehicle Control ECU Assembly 4.177,5.406 5.094,5.604 0.917,0.198 10 false MG ECU 1.5,7 2.417,7.198 0.917,0.198 10 false Boost IPM 1.708,7.365 2.479,7.563 0.771,0.198 10 false Reactor 5.417,2 7.083,2.333 1.667,0.333 10 false *1: Temperature Sensor on IPM for MG2 5.417,6.417 7.083,6.833 1.667,0.417 10 false *2: Temperature Sensor on Boost IPM (Upper) 5.417,7.25 7.083,7.75 1.667,0.5 10 false *3: Temperature Sensor on Boost IPM (Lower) 5.417,8.083 7.083,8.635 1.667,0.552 10 false *4: HV Coolant Temperature Sensor 0.865,1.135 1.021,1.333 0.156,0.198 10 false W 0.885,4.052 1.042,4.25 0.156,0.198 10 false V 0.885,1.302 1.042,1.5 0.156,0.198 10 false U 0.865,3.729 1.021,3.927 0.156,0.198 10 false W 0.885,3.885 1.042,4.083 0.156,0.198 10 false U 0.885,1.469 1.042,1.667 0.156,0.198 10 false V



h.

Inverter Current Sensor

i.

The inverter current sensors detect the amperage of the three-phase alternating current that actuates generator (MG1) and motor (MG2). This actual amperage is used as feedback by the MG ECU.


ii.

Current sensors are used for the current sent to the three-phase windings of generator (MG1) and motor (MG2). The current sensors are located in the inverter with converter assembly for the U, V and W phases of each generator and motor.

W136966E01
3.844,1.875 4.427,1.042 4.427,1.042 4.594,1.042 true 3.313,1.75 2.813,1.833 2.813,1.833 2.646,1.833 true 2.427,1.563 2.927,1.563 true 1.188,1.719 2.625,1.906 1.438,0.188 10 false Inverter Current Sensor 2.083,0.563 3.219,0.833 1.135,0.271 10 false Generator/Motor 4.625,0.948 6.24,1.146 1.615,0.198 10 false Inverter Current Sensor 0.969,1.448 2.417,1.646 1.448,0.198 10 false Inverter Current Sensor 5.167,1.469 6.083,1.667 0.917,0.198 10 false MG ECU 3.281,0.396 3.438,0.594 0.156,0.198 10 false U 2.958,0.99 3.115,1.188 0.156,0.198 10 false V 3.802,1 3.958,1.198 0.156,0.198 10 false W 2.667,3.813 3.583,4.01 0.917,0.198 10 false Inverter 0.052,4.177 7.156,4.417 7.104,0.24 12 false Characteristics of Inverter Current Sensor: 1.573,4.792 2.031,4.99 0.458,0.198 10 false 4.5 1.583,5.542 2.042,5.74 0.458,0.198 10 false 2.5 1.594,6.313 2.052,6.51 0.458,0.198 10 false 0.5 1.969,6.635 2.427,6.833 0.458,0.198 10 false -300 4.083,6.635 4.542,6.833 0.458,0.198 10 false 0 6,6.635 6.458,6.833 0.458,0.198 10 false 300 1.542,6.635 2,6.833 0.458,0.198 10 false MG1 1.542,6.885 2,7.083 0.458,0.198 10 false MG2 1.969,6.885 2.427,7.083 0.458,0.198 10 false -600 6,6.885 6.458,7.083 0.458,0.198 10 false 600 0.531,5.313 1.458,5.667 0.927,0.354 10 false Sensor Output Voltage (V) 3.813,7.302 5.5,7.5 1.688,0.198 10 false Current (A)