Home › Engine / Hybrid System › A25A-FXS (ENGINE CONTROL) › SFI SYSTEM › 2017.09–2020.08
NM33C0E _51 Engine / Hybrid System _068016 A25A-FXS ENGINE CONTROL _0331671 SFI SYSTEM DE DETAILS F

A25A-FXS ENGINE CONTROL  SFI SYSTEM  DETAILS  THERMOSTAT HEATER CONTROL  


CONSTRUCTION


a.

Current is sent to the heater to heat the wax when the engine speed and engine load are high in order to assist opening the valve of the thermostat with heater. This contributes to decreased coolant temperature at the inlet port when the engine speed and engine load are high, ensuring high performance while preventing engine knock.

W136154C01
3.604,1.75 4.938,1.75 true 3.583,2.302 4.917,2.302 true 4.969,1.635 5.167,1.833 0.198,0.198 10 false *1 4.979,2.188 5.177,2.385 0.198,0.198 10 false *2
*1 Heater *2 Wax