NM33C0E_51Engine / Hybrid System_068017A25A-FXS EMISSION CONTROL_0331690BLOWBY GAS VENTILATION SYSTEMDEDETAILSF
A25A-FXS EMISSION CONTROL BLOWBY GAS VENTILATION SYSTEM DETAILS VENTILATION CASE
CONSTRUCTION
a.
A Labyrinth structure is used for the oil mist separator of the No. 1 ventilation case. By enhancing the oil mist collection rate, oil consumption and the buildup of deposits have been decreased.