Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM
NM33C0E _58 Vehicle Interior _068285 HEATING / AIR CONDITIONING _0332682 AIR CONDITIONING SYSTEM DE DETAILS F

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  DETAILS  NO. 1 COOLER EVAPORATOR  


CONSTRUCTION


a.

Ejector Cycle System (ECS) Type No. 1 Cooler Evaporator Sub-assembly

i.

The ECS type no. 1 cooler evaporator sub-assembly is composed of a tank, tubes and cooling fins. For the tubes, extrusion is used so that small passages are created, helping to achieve excellent heat transmission performance and to allow for a thinner design (38 mm). In addition, reductions in the height and pitch of the fins and reductions in the thickness of the tubes are achieved, helping to promote heat transmission and to allow for thinner core materials. The result of this is a significant reduction in size and weight of the evaporator. Also, clean coat is used for the main body of the evaporator, helping to suppress development of bacteria, which may cause bad smells, and chrome-free surface treatment is used in consideration of the environment.


ii.

The ejector is positioned in the ECS type no. 1 cooler evaporator sub-assembly top tank. The flow of the refrigerant is divided into the upwind and downwind sections as it passes through the evaporator, allowing for the ejector cycle (EJECS II)*.

HINT:

*: Ejector cycle (EJECS II) is a registered trademark owned by DENSO Corporation.


Y195005C03
1.063,1.156 1.063,0.417 1.063,0.417 0.833,0.417 true 1.708,1.021 1.708,0.406 1.708,0.406 1.958,0.406 true 1.896,3.115 1.896,3.531 1.896,3.531 2.396,3.531 true 5.729,1.417 5.823,1.073 5.823,1.073 6.042,1.073 true 5.375,2.01 5.156,2.521 5.156,2.521 4.854,2.521 true 0.656,0.344 0.969,0.5 0.313,0.156 10 false *1 2,0.333 2.313,0.49 0.313,0.156 10 false *2 2.458,3.448 2.771,3.604 0.313,0.156 10 false *3 4.667,2.438 4.979,2.594 0.313,0.156 10 false *4 6.104,1.01 6.396,1.219 0.292,0.208 10 false *5
*1 Top tank *2 Ejector
*3 Bottom tank *4 Cooling fin
*5 Multiple passage tube - -



iii.

The ejector cycle system operates as follows:

·

In a conventional refrigerant cycle, liquid refrigerant gas is sent into the cooler evaporator sub-assembly using the cooler expansion valve, generating cold air. However, a rapid decrease in the refrigerant pressure forms swirls, causing energy loss.

·

In this ejector cycle, the energy loss caused by the cooler expansion valve is utilized by the operation of the ejector that injects and expands a high-pressure refrigerant, thus reducing energy consumption.

Conventional Refrigerant Cycle
Y102838E08
1.927,3.01 1.927,2.76 1.927,2.76 1.208,2.531 true 0.156,0.573 1.75,0.802 1.594,0.229 10 false Cooler Expansion Valve: 0.375,3.813 1.406,4.115 1.031,0.302 10 false Low-pressure 0.385,0.979 1.417,1.281 1.031,0.302 10 false High-pressure 1.438,3.073 2.688,3.667 1.25,0.594 10 false Energy loss caused by swirls 4.458,3.885 5.646,4.438 1.188,0.552 10 false Cooler Evaporator 4.99,2.198 6.052,2.958 1.063,0.76 10 false Compressor with Motor Assembly 4.427,1.323 5.583,1.823 1.156,0.5 10 false Cooler Condenser

Ejector Cycle (EJECS 2)
Y218816E01
3.99,1.51 4.385,1.813 4.385,1.813 4.74,1.813 true 3.979,1.125 4.385,0.313 4.385,0.313 4.74,0.313 true 2.958,2.135 3.344,2.135 false 0.542,0.25 1.146,0.448 0.604,0.198 10 false Ejector: 0.531,1.146 2.438,1.51 1.906,0.365 10 false Refrigerant from the condenser with receiver assembly 0.625,2.063 2.927,2.667 2.302,0.604 10 false Refrigerant from the cooler evaporator sub-assembly at the downwind side 4.792,1.74 6.448,2.458 1.656,0.719 10 false Suction flow generated by decrease in the pressure 4.823,0.271 6.469,0.781 1.646,0.51 10 false Suction flow generated by decrease in the pressure 0.573,3.573 2.094,3.771 1.521,0.198 10 false Cooler Expansion Valve 4,3.438 5.813,3.729 1.813,0.292 10 false Cooler Condenser Assembly 3.927,3.823 6.031,4.115 2.104,0.292 10 false Compressor with Motor Assembly 4.552,4.552 5.375,4.75 0.823,0.198 10 false Upwind Side 4.469,5.104 5.51,5.313 1.042,0.208 10 false Downwind Side 3.563,5.656 5.448,6.042 1.885,0.385 10 false Capillary Tube (valve to reduce the refrigerant pressure) 3.208,6.438 6.448,6.813 3.24,0.375 10 false No. 1 Cooler Evaporator Sub-assembly (ECS Type)



iv.

Structure and operation of ejector as follows:

·

The ejector is composed of the nozzle, mixing and diffuser sections.

·

A high temperature and high pressure liquid refrigerant flowing from the cooler condenser assembly is depressurized at the nozzle section and sucks in the low temperature and low pressure gaseous refrigerant from the no. 1 cooler evaporator sub-assembly on the downwind side.

·

The refrigerants are mixed at the mixing section, and the flow speed is decreased at the diffuser section so that the refrigerant is pressurized and flows into the no. 1 cooler evaporator sub-assembly on the upwind side. This realizes the condition where the refrigerant pressure in the no. 1 cooler evaporator sub-assembly on the downwind side is considerably lower than that on the upwind side, creating the lower temperature conditions.

·

Therefore, air cooled by the no. 1 cooler evaporator sub-assembly on the upwind side can be further cooled by the no. 1 cooler evaporator sub-assembly on the downwind side, thus improving the efficiency of the no. 1 cooler evaporator sub-assembly.

·

As a result of this, energy efficiency and cooling performance are enhanced. This allows for the reduction in the rotation speed of the electric inverter compressor, resulting in lower power consumption of the air conditioning.

Y196070E02
3.01,3.167 3.198,2.396 3.198,2.396 3.344,2.396 true 5.177,3.083 5.813,3.083 true 1.469,3.229 1.698,3.229 1.698,3.229 2.479,2.792 true 1.542,4.833 1.771,4.833 1.771,4.833 2.365,5.375 true 3.615,3.271 3.896,3.875 3.896,3.875 4.344,3.875 true 4.604,5.542 4.906,4.792 4.906,4.792 5.271,4.792 true 0.052,0.49 1.104,1.115 1.052,0.625 10 false From condenser with receiver assembly 0.135,1.677 2.073,2.302 1.938,0.625 10 false From the cooler evaporator sub-assembly at the downwind side 2.469,1.469 2.948,1.75 0.479,0.281 10 false Nozzle 3.094,1.479 4.073,1.823 0.979,0.344 10 false Mixing Section 4.167,1.469 5.135,1.823 0.969,0.354 10 false Diffuser Section 5.354,0.479 7.125,1.031 1.771,0.552 10 false To the cooler evaporator sub-assembly at the upwind side 1.292,2.448 1.906,2.646 0.615,0.198 10 false Pressure 3.385,2.323 5.698,2.594 2.313,0.271 10 true Suction due to decrease in pressure 5.844,3.01 7.083,3.594 1.24,0.583 10 false Pressure rise due to decrease in speed 0.167,3.146 1.448,3.76 1.281,0.615 10 false Refrigerant flow from condenser with receiver assembly 4.396,3.792 6.958,4.552 2.563,0.76 10 true Refrigerant flow from the downwind side of the cooler evaporator sub-assembly 1.208,4.469 1.865,4.667 0.656,0.198 10 false Flow Rate 0.26,4.75 1.531,5.542 1.271,0.792 10 false Refrigerant flow from condenser with receiver assembly 5.344,4.719 6.854,5.542 1.51,0.823 10 false Refrigerant flow from condenser with receiver assembly




b.

Beneficial Refrigerant Stream (BRS) Type No. 1 Cooler Evaporator Sub-assembly

i.

The Beneficial Refrigerant Stream (BRS) evaporator is composed of tanks, tubes and cooling fins. The tubes project outwards and are shaped as a fine duct in an attempt to offer superior conductivity with a more narrow width. Furthermore, the evaporator has been drastically miniaturized and lightened through efforts to promote conductivity through shrinking the fin height, tube thickness and fin pitch, as well as by thinning the core material.


ii.

The route that refrigerant passes through within the evaporator is optimized and pressure losses are reduced in an effort to increase performance and decrease size.


iii.

The refrigerant route of Beneficial Refrigerant Stream (BRS) type no. 1 cooler evaporator sub-assembly as follows:

·

While flowing through the evaporator tubes, refrigerant exchanges heat and vaporizes from a mist state.

·

As shown in the illustration below, the proportion of tubes through which refrigerant flows increases as the direction the refrigerant flows in changes. This makes it easier for refrigerant to flow and decreases pressure losses.

Y147366E01
1.427,0.219 2.344,0.417 0.917,0.198 10 false Flow 1 2.948,0.219 3.865,0.417 0.917,0.198 10 false Flow 2 4.438,0.219 4.958,0.5 0.521,0.281 10 false Flow 3 5.969,0.219 6.49,0.5 0.521,0.281 10 false Flow 4 5.458,0.583 6.229,0.885 0.771,0.302 10 false Discharge 5.458,2.01 6.229,2.313 0.771,0.302 10 false Discharge 0.948,0.646 1.865,0.844 0.917,0.198 10 false Influx 0.948,2.063 1.865,2.26 0.917,0.198 10 false Influx 0.396,1.031 0.74,1.552 0.344,0.521 10 false BRS Type 0.24,2.521 0.906,3.094 0.667,0.573 10 false Traditional Types 0.521,3.552 1.917,3.74 1.396,0.188 10 false : Refrigerant flow