Thermostat
Condition Specified Condition
Standard valve opening temperature 80 to 84°C (176 to 183°F)
Standard valve lift 8.0 mm (0.315 in.) or more at 95°C (203°F)

Tester Connection Condition Specified Condition
1 - 2 Always 10.6 to 14.2 Ω

Flow Shutting Valve
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 22 to 28 Ω

Radiator
Item Condition Specified Condition
Radiator cap sub-assembly Standard pressure
(for brand-new reserve tank cap)
74 to 103 kPa (0.8 to 1.1 kgf/cm2, 10.7 to 14.9 psi)
Minimum pressure
(for used reserve tank cap)