Home › General › SPECIFICATIONS › HYBRID / BATTERY CONTROL › 2017.09–2020.08
RM33C0E _V1 General _065431 SPECIFICATIONS _0319208 HYBRID / BATTERY CONTROL F

SPECIFICATIONS  HYBRID / BATTERY CONTROL  SERVICE DATA  


Reserve Tank Cap (for Inverter)
Item Specified Condition
Standard Value (for Brand-new Cap) 94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 18 psi)
Minimum Standard Value (for Used Cap) 94 kPa (1.0 kgf/cm2, 13.6 psi)

Relay
Item Tester Connection Specified Condition
IGCT Relay (IGCT)
Resistance
3 - 5 10 kΩ or higher
Auxiliary battery voltage not applied between terminals 1 and 2
Below 1 Ω
Auxiliary battery voltage applied between terminals 1 and 2

HV Battery Junction Block Assembly
SMRB
Resistance
z25-1 (+) - s2-1 (CBI) 10 kΩ or higher
Auxiliary battery voltage not applied between terminals R22-1 (SMRB) and R22-3 (GND)
Below 1 Ω
Auxiliary battery voltage applied between terminals R22-1 (SMRB) and R22-3 (GND)
R25-1 (SMRB) - R22-3 (GND) 25.0 to 59.0 Ω at -40 to 80°C (-40 to 176°F)
SMRG
Resistance
z20-1 (-) - s3-1 (CEI) 10 kΩ or higher
Auxiliary battery voltage not applied between terminals R22-4 (SMRG) and R22-3 (GND)
Below 1 Ω
Auxiliary battery voltage applied between terminals R22-4 (SMRG) and R22-3 (GND)
R22-4 (SMRG) - R22-3 (GND) 25.0 to 59.0 Ω at -40 to 80°C (-40 to 176°F)
SMRP
Resistance
z20-1 (-) - s3-1 (CEI) 10 kΩ or higher
Auxiliary battery voltage not applied between terminals R22-2 (SMRP) and R22-3 (GND)
24.3 to 29.7 Ω
Auxiliary battery voltage applied between terminals R22-2 (SMRP) and R22-3 (GND)
R22-2 (SMRP) - R22-3 (GND) 140 to 290 Ω at -40 to 80°C (-40 to 176°F)

Electric Parking Brake Switch Assembly (for LHD)
Electric Parking Brake Switch Assembly
Resistance
K37-14 (S) - K37-16 (GND1) Below 1 Ω
EV mode switch (electric parking brake switch assembly) being pushed and held
10 kΩ or higher
EV mode switch (electric parking brake switch assembly) not pushed
K37-13 (B) - K37-16 (GND1) Below 1 Ω
NORMAL mode switch (electric parking brake switch assembly) being pushed and held
10 kΩ or higher
NORMAL mode switch (electric parking brake switch assembly) not pushed
K37-12 (P) - K37-16 (GND1) Below 1 Ω
SPORT mode switch (electric parking brake switch assembly) being pushed and held
10 kΩ or higher
SPORT mode switch (electric parking brake switch assembly) not pushed

Electric Parking Brake Switch Assembly (for RHD)
Electric Parking Brake Switch Assembly
Resistance
K37-11 (S) - K37-9 (GND1) Below 1 Ω
EV mode switch (electric parking brake switch assembly) being pushed and held
10 kΩ or higher
EV mode switch (electric parking brake switch assembly) not pushed
K37-12 (B) - K37-9 (GND1) Below 1 Ω
NORMAL mode switch (electric parking brake switch assembly) being pushed and held
10 kΩ or higher
NORMAL mode switch (electric parking brake switch assembly) not pushed
K37-13 (P) - K37-9 (GND1) Below 1 Ω
SPORT mode switch (electric parking brake switch assembly) being pushed and held
10 kΩ or higher
SPORT mode switch (electric parking brake switch assembly) not pushed

Service Plug Grip
Tester Connection Condition Specified Condition
Service Plug Grip Always Below 1 Ω

Hybrid Battery Terminal Block
Hybrid Battery Terminal Block Always Below 1 Ω