This circuit is the power source circuit for the combination meter assembly. This circuit provides two types of power sources; one is a constant power source, and the other is an IG power source.
When replacing the combination meter assembly, always replace it with a new one. If a combination meter assembly which was installed to another vehicle is used, the information stored in it will not match the information from the vehicle and a DTC may be stored.
Inspect the fuses of circuits related to this system before performing the following procedure.
Disconnect the K21 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| K21-21 (ES) - Body ground | Always | Below 1 Ω |
| K21-2 (EP) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| K21-39 (IG+) - Body ground | Power switch off | Below 1 V |
| Power switch on (IG) | 11 to 14 V | |
| K21-40 (B) - Body ground | Power switch off | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG