88719A
1.INSPECT AIR CONDITIONER PRESSURE SENSOR
Check the wire harness.
Disconnect the A18 air conditioner pressure sensor connector.
Disconnect the K55 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A18-1 (-) - K55-3 (SG-4) | Always | Below 1 Ω |
| A18-2 (PR) - K55-24 (PRE) | Always | Below 1 Ω |
| A18-3 (+) - K55-6 (S5-3) | Always | Below 1 Ω |
| A18-1 (-) or K55-3 (SG-4) - Other terminals and body ground | Always | 10 kΩ or higher |
| A18-2 (PR) or K55-24 (PRE) - Other terminals and body ground | Always | 10 kΩ or higher |
| A18-3 (+) or K55-6 (S5-3) - Other terminals and body ground | Always | 10 kΩ or higher |
If the result is not as specified, repair or replace the wire harness.
Connect the K55 air conditioning amplifier assembly connector.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A18-3 (+) - Body ground | Power switch on (IG) | 4.75 to 5.25 V |
If the result is not as specified, repair or replace the wire harness or replace air conditioning amplifier assembly.
Check the air conditioner pressure sensor.
Connect the A18 air conditioner pressure sensor connector.
Install a manifold gauge set.
Turn the A/C switch on.
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
Measure the voltage according to the value(s) in the table below.
Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| K55-24 (PRE) - K55-3 (SG-4) | Refrigerant pressure: Normal pressure (less than 3025 kPa (30.8 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 26 psi)) | 0.74 to 4.61 V |
If the result is not as specified, replace the air conditioner pressure sensor.