CHECK MILLIMETER WAVE RADAR SENSOR ASSEMBLY
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| A30-8 (IGB) - A30-1 (SGND) | R - W-B | Power source | Power switch on (IG) | 11 to 14 V |
| A30-1 (SGND) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
Check for pulses according to the value(s) in the table below.
If the waveform is not similar to that shown in the illustration, malfunction of a CAN bus line, terminating resistor or the millimeter wave radar sensor assembly is suspected.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| A30-3 (CA2H) - A30-1 (SGND) | R - W-B | CAN communication signal | Power switch on (IG) | Pulse generation
(See waveform 1) |
| A30-2 (CA2L) - A30-1 (SGND) | W - W-B | CAN communication signal | Power switch on (IG) | Pulse generation
(See waveform 2) |
| A30-5 (CA1P) - A30-1 (SGND) | G - W-B | CAN communication signal | Power switch on (IG) | Pulse generation
(See waveform 1) |
| A30-6 (CA1N) - A30-1 (SGND) | W - W-B | CAN communication signal | Power switch on (IG) | Pulse generation
(See waveform 2) |
Waveform 1
| Item | Content |
|---|---|
| Terminal Name | Between A30-3 (CA2H) and A30-1 (SGND)
Between A30-5 (CA1P) and A30-1 (SGND) |
| Tester Range | 1 V/DIV., 10 μsec./DIV. |
| Condition | Power switch on (IG) |
The waveform varies depending on the CAN communication signal.
Waveform 2
| Item | Content |
|---|---|
| Terminal Name | Between A30-2 (CA2L) and A30-1 (SGND)
Between A30-6 (CA1N) and A30-1 (SGND) |
| Tester Range | 1 V/DIV., 10 μsec./DIV. |
| Condition | Power switch on (IG) |
The waveform varies depending on the CAN communication signal.
CHECK FORWARD RECOGNITION CAMERA
DTCs may be stored when connectors are disconnected during inspection. Therefore, be sure to clear the DTCs using the GTS once the inspection has been completed.
Do not apply excessive force to the V6 forward recognition camera connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| V6-7 (IGB) - V6-10 (GND) | LA-P - LA | Power source | Power switch on (IG) | 11 to 14 V |
| Power switch off | Below 1 V | |||
| V6-10 (GND) - Body ground | LA - Body ground | Ground | Always | Below 1 Ω |
Check for pulses according to the value(s) in the table below.
If the waveform is not similar to that shown in the illustration, malfunction of a CAN bus line, terminating resistor or the forward recognition camera is suspected.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| V6-5 (CA1P) - V6-10 (GND) | L - LA | CAN communication signal | Power switch on (IG) | Pulse generation
(See waveform 1) |
| V6-11 (CA1N) - V6-10 (GND) | W - LA | CAN communication signal | Power switch on (IG) | Pulse generation
(See waveform 2) |
| V6-6 (CANH) - V6-10 (GND) | G - LA | CAN communication signal | Power switch on (IG) | Pulse generation
(See waveform 1) |
| V6-12 (CANL) - V6-10 (GND) | W - LA | CAN communication signal | Power switch on (IG) | Pulse generation
(See waveform 2) |
Waveform 1
| Item | Content |
|---|---|
| Terminal Name | Between V6-5 (CA1P) and V6-10 (GND)
Between V6-6 (CANH) and V6-10 (GND) |
| Tester Range | 1 V/DIV., 10 μsec./DIV. |
| Condition | Power switch on (IG) |
The waveform varies depending on the CAN communication signal.
Waveform 2
| Item | Content |
|---|---|
| Terminal Name | Between V6-11 (CA1N) and V6-10 (GND)
Between V6-12 (CANL) and V6-10 (GND) |
| Tester Range | 1 V/DIV., 10 μsec./DIV. |
| Condition | Power switch on (IG) |
The waveform varies depending on the CAN communication signal.