Home › Vehicle Interior › DOOR LOCK › FRONT DOOR LOCK
RM33C0E _58 Vehicle Interior _065455 DOOR LOCK _0333668 FRONT DOOR LOCK G

DOOR LOCK  FRONT DOOR LOCK  INSPECTION  


PROCEDURE

Hide 69040A 1.INSPECT FRONT DOOR LOCK WITH MOTOR ASSEMBLY LH

a.
B340410C17
2.156,2.063 2.469,2.219 0.313,0.156 10 false *a 1.583,2.479 1.896,2.635 0.313,0.156 10 false *b 0.906,2.802 1.219,2.958 0.313,0.156 10 false *c
*a Unlock
*b Lock
*c Component without harness connected
(Front Door Lock with Motor Assembly LH)


Check the operation of the door lock motor.

i.

Apply auxiliary battery voltage and check the operation of the door lock motor.

OK:
Auxiliary Battery Connection Result
Auxiliary battery positive (+) → Terminal 4
Auxiliary battery negative (-) → Terminal 1
Locks
Auxiliary battery positive (+) → Terminal 1
Auxiliary battery negative (-) → Terminal 4
Unlocks


If the result is not as specified, replace the front door lock with motor assembly LH.



b.

Check the operation of the door unlock detection switch.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
7 - 8 Locked 10 kΩ or higher
7 - 8 Unlocked Below 1 Ω


If the result is not as specified, replace the front door lock with motor assembly LH.



c.
B347368C10
2.938,1.385 3.25,1.583 0.313,0.198 10 false *a 3.135,0.854 3.385,1.094 0.25,0.24 10 false *b 2.938,0.396 3.25,0.594 0.313,0.198 10 false *c 0.719,2.958 1.031,3.156 0.313,0.198 10 false *d
*a Unlock
*b Neutral
*c Lock
*d Component without harness connected
(Front Door Lock with Motor Assembly LH)


Check the operation of the door key lock and unlock switch. (for LHD)

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
9 - 7 Held to lock side Below 1 Ω
9 - 7 Neutral or held to unlock side 10 kΩ or higher
10 - 7 Held to unlock side Below 1 Ω
10 - 7 Neutral or held to lock side 10 kΩ or higher


If the result is not as specified, replace the front door lock with motor assembly LH.



Hide 69030A 2.INSPECT FRONT DOOR LOCK WITH MOTOR ASSEMBLY RH

a.
B340409C20
1.115,2.083 1.427,2.24 0.313,0.156 10 false *a 1.729,2.5 2.042,2.656 0.313,0.156 10 false *b 0.854,2.802 1.167,2.958 0.313,0.156 10 false *c
*a Unlock
*b Lock
*c Component without harness connected
(Front Door Lock with Motor Assembly RH)


Check the operation of the door lock motor.

i.

Apply auxiliary battery voltage and check the operation of the door lock motor.

OK:
Auxiliary Battery Connection Result
Auxiliary battery positive (+) → Terminal 4
Auxiliary battery negative (-) → Terminal 1
Locks
Auxiliary battery positive (+) → Terminal 1
Auxiliary battery negative (-) → Terminal 4
Unlocks


If the result is not as specified, replace the front door lock with motor assembly RH.



b.

Check the operation of the door unlock detection switch.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
7 - 8 Locked 10 kΩ or higher
7 - 8 Unlocked Below 1 Ω


If the result is not as specified, replace the front door lock with motor assembly RH.



c.
B340408C28
0.583,1.385 0.896,1.542 0.313,0.156 10 false *a 0.427,0.979 0.74,1.135 0.313,0.156 10 false *b 0.615,0.49 0.927,0.646 0.313,0.156 10 false *c 0.917,2.823 1.229,3.021 0.313,0.198 10 false *d
*a Unlock
*b Neutral
*c Lock
*d Component without harness connected
(Front Door Lock with Motor Assembly RH)


Check the operation of the door key lock and unlock switch. (for RHD)

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
5 - 8 Held to unlock side Below 1 Ω
5 - 8 Neutral or held to lock side 10 kΩ or higher
6 - 8 Held to lock side Below 1 Ω
6 - 8 Neutral or held to unlock side 10 kΩ or higher


If the result is not as specified, replace the front door lock with motor assembly RH.