Home › Audio / Visual / Telematics › PARK ASSIST / MONITORING › BLIND SPOT MONITOR SYSTEM
RM33C0E _56 Audio / Visual / Telematics _065452 PARK ASSIST / MONITORING _0333742 BLIND SPOT MONITOR SYSTEM J

PARK ASSIST / MONITORING  BLIND SPOT MONITOR SYSTEM  Buzzer does not Sound  


WIRING DIAGRAM

E254403E88
0.156,1.021 1.563,1.219 1.406,0.198 10 false from IG1-NO. 3 Relay 3.281,1.313 3.625,1.51 0.344,0.198 10 false R26 3.281,1.469 4.896,1.844 1.615,0.375 10 false RCTA Buzzer (Blind Spot Monitor Buzzer) 5.604,1.927 5.896,2.125 0.292,0.198 10 false W6 5.604,2.083 6.802,2.406 1.198,0.323 10 false Blind Spot Monitor Sensor LH 3.354,0.927 3.5,1.104 0.146,0.177 10 false 1 5.646,1.021 5.979,1.219 0.333,0.198 10 false BUZ 5.479,0.917 5.625,1.094 0.146,0.177 10 false 3 4.698,0.917 4.844,1.094 0.146,0.177 10 false 2 2.24,1.177 2.958,1.448 0.719,0.271 10 false DSS-IG 4.302,1.021 4.635,1.219 0.333,0.198 10 false BZN 3.51,1.01 3.844,1.208 0.333,0.198 10 false BZP

CAUTION / NOTICE / HINT

NOTICE:
·

When checking for DTCs, make sure that the blind spot monitor system is turned on.

·

Inspect the fuses for circuits related to this system before performing the following procedure.



PROCEDURE

1.CHECK RCTA BUZZER (BLIND SPOT MONITOR BUZZER)
a.

Check that the RCTA buzzer (blind spot monitor buzzer) sounds when the initial check is performed.

Click hereAudio / Visual / Telematics>PARK ASSIST / MONITORING>BLIND SPOT MONITOR SYSTEM>SYSTEM DESCRIPTION

OK:

RCTA buzzer sounds



Result:
Proceed to
OK
NG



OK

NG

2.CHECK DTC
2.CHECK DTC
a.

Turn the power switch off.


b.

Turn the power switch on (IG).


c.

Recheck for DTCs and check if the same DTC is output again.

Body Electrical > Blind Spot Monitor Slave > Trouble Codes
50001 314
OK:

No DTCs are output.



Result:
Proceed to
OK
NG



OK

3.CHECK HARNESS AND CONNECTOR (RCTA BUZZER - BLIND SPOT MONITOR SENSOR LH)

NG

3.CHECK HARNESS AND CONNECTOR (RCTA BUZZER - BLIND SPOT MONITOR SENSOR LH)
a.

Disconnect the R26 RCTA buzzer (blind spot monitor buzzer) connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
R26-1 (BZP) - Body ground Power Switch on (IG) 11 to 14 V
R26-2 (BZN) or W6-3 (BUZ) - Body ground Below 1 V
R26-2 (BZN) - R26-1 (BZP) Below 1 V



Result:
Proceed to
OK
NG



OK

4.CHECK HARNESS AND CONNECTOR (RCTA BUZZER - BLIND SPOT MONITOR SENSOR LH AND AUXILIARY BATTERY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK HARNESS AND CONNECTOR (RCTA BUZZER - BLIND SPOT MONITOR SENSOR LH AND AUXILIARY BATTERY)
a.

Disconnect the R26 RCTA buzzer (blind spot monitor buzzer) connector.


b.

Disconnect the W6 blind spot monitor sensor LH connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
R26-2 (BZN) - W6-3 (BUZ) Always Below 1 Ω
R26-2 (BZN) or W6-3 (BUZ) - Body ground Always 10 kΩ or higher



d.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
R26-2 (BZN) or W6-3 (BUZ) - Body ground Power switch on (IG) Below 1 V
R26-1 (BZP) - Body ground Power switch on (IG) 11 to 14 V
R26-1 (BZP) - Body ground Power switch off Below 1 V



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR