This circuit provides power to operate the blind spot monitor sensor.
Inspect the fuses for circuits related to this system before performing the following procedure.
Disconnect the W5 blind spot monitor sensor RH connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| W5-5 (BRB) - Body ground | Power switch on (IG) | 11 to 14 V |
| W5-5 (BRB) - Body ground | Power switch off | Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| W5-10 (BRGD) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the W6 blind spot monitor sensor LH connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| W6-5 (BLB) - Body ground | Power switch on (IG) | 11 to 14 V |
| W6-5 (BLB) - Body ground | Power switch off | Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| W6-10 (BLGD) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG