HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  DATA LIST / ACTIVE TEST  


DATA LIST


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus:

i.

for Air Conditioner: Body Electrical / Air Conditioner / Data List.


ii.

for Engine: Powertrain / Engine / Data List.



e.

Read the Data List according to the display on the GTS.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Room Temperature Sensor Cooler (room temp. sensor) thermistor Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F)
Actual cabin temperature displayed Cooler (room temp. sensor) thermistor circuit malfunction
·

When open circuit: -6.50°C (20.30°F)

·

When short circuit: 57.25°C (135.05°F)


Ambient Temp Sensor Thermistor assembly Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature displayed Thermistor assembly circuit malfunction
·

When open circuit: -23.30°C (-9.94°F)

·

When short circuit: 65.95°C (150.71°F)


Adjusted Ambient Temp Adjusted ambient temperature Min.: -30.80°C (-23.44°F)
Max.: 50.80°C (123.44°F)
Adjust ambient temperature displayed Air conditioning amplifier assembly circuit malfunction
Evaporator Fin Thermistor No. 1 cooler thermistor Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature displayed No. 1 cooler thermistor circuit malfunction
·

When open circuit: -29.70°C (-21.46°F)

·

When short circuit: 59.55°C (139.19°F)


Evaporator Target Temp Evaporator target temperature Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Evaporator target temperature displayed No. 1 cooler thermistor circuit malfunction
·

When open circuit: -327.68°C (-557.82°F)

·

When short circuit: 327.67°C (621.81°F)


Solar Sensor (D Side) Driver side automatic light control sensor Min.: 0
Max.: 255
Driver side automatic light control sensor value increases as brightness increases Driver side automatic light control sensor circuit malfunction
·

When open circuit: 0

·

When short circuit: 255


Solar Sensor (P Side) Front passenger side automatic light control sensor Min.: 0
Max.: 255
Front passenger side automatic light control sensor value increases as brightness increases Front passenger side automatic light control sensor circuit malfunction
·

When open circuit: 0

·

When short circuit: 255


Engine Coolant Temp Engine coolant temperature sensor Min.: 1.30°C (34.34°F)
Max.: 90.55°C (194.99°F)
Actual engine coolant temperature displayed
·

SFI system malfunction

·

CAN communication system malfunction


Blower Motor Speed Level Blower motor speed level Min.: 0
Max.: 31
Displayed speed level increases in range between 0 and 31 as blower motor speed increases Blower motor with fan sub-assembly circuit malfunction
Regulator Pressure Sensor Air conditioner pressure sensor Min.: -0.4566 MPaG
Max.: 3.2943 MPaG
Actual refrigerant pressure displayed
·

Refrigerant line (gas leak etc.)

·

Air conditioner pressure sensor circuit malfunction


Air Outlet Servo Pulse (R) No. 2 air conditioning radiator damper servo sub-assembly target pulse Min.: 128
Max.: 383
·

FACE: 260 (pulse)

·

B/L: 212 (pulse)

·

FOOT: 182 (pulse)

·

F/D: 223 (pulse)

·

SHUT: 158 (pulse)

·

D/F: 177 (pulse)


No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction
Air Outlet Servo Actual Pls(R) No. 2 air conditioning radiator damper servo sub-assembly actual pulse Min.: 128
Max.: 383
·

FACE: 260 (pulse)

·

B/L: 212 (pulse)

·

FOOT: 182 (pulse)

·

F/D: 223 (pulse)

·

SHUT: 158 (pulse)

·

D/F: 177 (pulse)


No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction
Air Mix Servo Targ Pulse(R) No. 3 air conditioning radiator damper servo sub-assembly target pulse Min.: 128
Max.: 383
·

MAX COLD: 257 (pulse)

·

MAX HOT: 165 (pulse)


No. 3 air conditioning radiator damper servo sub-assembly circuit malfunction*1
Air Mix Servo Actual Pulse(R) No. 3 air conditioning radiator damper servo sub-assembly actual pulse Min.: 128
Max.: 383
·

MAX COLD: 257 (pulse)

·

MAX HOT: 165 (pulse)


No. 3 air conditioning radiator damper servo sub-assembly circuit malfunction*1
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) target pulse Min.: 128
Max.: 383
for LHD:
·

MAX COLD: 257 (pulse)

·

MAX HOT: 165 (pulse)


for RHD:
·

MAX COLD: 255 (pulse)

·

MAX HOT: 347 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) circuit malfunction
Air Mix Servo Actual Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) actual pulse Min.: 128
Max.: 383
for LHD:
·

MAX COLD: 257 (pulse)

·

MAX HOT: 165 (pulse)


for RHD:
·

MAX COLD: 255 (pulse)

·

MAX HOT: 347 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) circuit malfunction
Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) target pulse Min.: 128
Max.: 383
for LHD:
·

MAX COLD: 255 (pulse)

·

MAX HOT: 347 (pulse)


for RHD:
·

MAX COLD: 257 (pulse)

·

MAX HOT: 165 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) circuit malfunction
Air Mix Servo Actual Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) actual pulse Min.: 128
Max.: 383
for LHD:
·

MAX COLD: 255 (pulse)

·

MAX HOT: 347 (pulse)


for RHD:
·

MAX COLD: 257 (pulse)

·

MAX HOT: 165 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) circuit malfunction
Air Outlet Servo Pulse (D)
for LHD (for 3 Zone Type):

No. 4 air conditioning radiator damper servo sub-assembly target pulse


for LHD (except 3 Zone Type):

No. 1 air conditioning radiator damper servo sub-assembly (mode) target pulse


for RHD:

No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) target pulse


Min.: 128
Max.: 383
for LHD (for 3 Zone Type):
·

FACE-R: 271 (pulse)

·

FACE: 256 (pulse)

·

FACE1: 256 (pulse)

·

FACE2: 256 (pulse)

·

B/L: 245 (pulse)

·

B/L2: 245 (pulse)

·

FOOT-R: 215 (pulse)

·

FOOT: 215 (pulse)

·

FOOT-D: 207 (pulse)

·

FOOT-0: 224 (pulse)

·

F/D: 192 (pulse)

·

DEF-FOOT: 173 (pulse)

·

DEF or SHUT: 164 (pulse)


for LHD (except 3 Zone Type):
·

FACE-R: 241 (pulse)

·

FACE: 256 (pulse)

·

FACE1: 256 (pulse)

·

FACE2: 256 (pulse)

·

B/L: 267 (pulse)

·

B/L2: 267 (pulse)

·

FOOT-R: 297 (pulse)

·

FOOT: 297 (pulse)

·

FOOT-D: 305 (pulse)

·

FOOT-0: 288 (pulse)

·

F/D: 320 (pulse)

·

DEF-FOOT: 339 (pulse)

·

DEF or SHUT: 348 (pulse)


for RHD:
·

FACE-R: 241 (pulse)

·

FACE: 256 (pulse)

·

FACE1: 256 (pulse)

·

FACE2: 256 (pulse)

·

B/L: 267 (pulse)

·

B/L2: 267 (pulse)

·

FOOT-R: 297 (pulse)

·

FOOT: 297 (pulse)

·

FOOT-D: 305 (pulse)

·

FOOT-0: 288 (pulse)

·

F/D: 320 (pulse)

·

DEF-FOOT: 339 (pulse)

·

DEF or SHUT: 348 (pulse)


for LHD (for 3 Zone Type):

No. 4 air conditioning radiator damper servo sub-assembly circuit malfunction


for LHD (except 3 Zone Type):

No. 1 air conditioning radiator damper servo sub-assembly (mode) circuit malfunction


for RHD:

No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) circuit malfunction


Air Outlet Servo Actu Pulse(D)
for LHD (for 3 Zone Type):

No. 4 air conditioning radiator damper servo sub-assembly actual pulse


for LHD (except 3 Zone Type):

No. 1 air conditioning radiator damper servo sub-assembly (mode) actual pulse


for RHD:

No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) actual pulse


Min.: 128
Max.: 383
for LHD (for 3 Zone Type):
·

FACE-R: 271 (pulse)

·

FACE: 256 (pulse)

·

FACE1: 256 (pulse)

·

FACE2: 256 (pulse)

·

B/L: 245 (pulse)

·

B/L2: 245 (pulse)

·

FOOT-R: 215 (pulse)

·

FOOT: 215 (pulse)

·

FOOT-D: 207 (pulse)

·

FOOT-0: 224 (pulse)

·

F/D: 192 (pulse)

·

DEF-FOOT: 173 (pulse)

·

DEF or SHUT: 164 (pulse)


for LHD (except 3 Zone Type):
·

FACE-R: 241 (pulse)

·

FACE: 256 (pulse)

·

FACE1: 256 (pulse)

·

FACE2: 256 (pulse)

·

B/L: 267 (pulse)

·

B/L2: 267 (pulse)

·

FOOT-R: 297 (pulse)

·

FOOT: 297 (pulse)

·

FOOT-D: 305 (pulse)

·

FOOT-0: 288 (pulse)

·

F/D: 320 (pulse)

·

DEF-FOOT: 339 (pulse)

·

DEF or SHUT: 348 (pulse)


for RHD:
·

FACE-R: 241 (pulse)

·

FACE: 256 (pulse)

·

FACE1: 256 (pulse)

·

FACE2: 256 (pulse)

·

B/L: 267 (pulse)

·

B/L2: 267 (pulse)

·

FOOT-R: 297 (pulse)

·

FOOT: 297 (pulse)

·

FOOT-D: 305 (pulse)

·

FOOT-0: 288 (pulse)

·

F/D: 320 (pulse)

·

DEF-FOOT: 339 (pulse)

·

DEF or SHUT: 348 (pulse)


for LHD (for 3 Zone Type):

No. 4 air conditioning radiator damper servo sub-assembly circuit malfunction


for LHD (except 3 Zone Type):

No. 1 air conditioning radiator damper servo sub-assembly (mode) circuit malfunction


for RHD:

No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) circuit malfunction


Air Outlet Servo Targ Pulse(P)
for LHD:

No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) target pulse


for RHD:

No. 4 air conditioning radiator damper servo sub-assembly target pulse


Min.: 128
Max.: 383
for LHD:
·

FACE-R: 241 (pulse)

·

FACE: 256 (pulse)

·

FACE1: 256 (pulse)

·

FACE2: 256 (pulse)

·

B/L: 267 (pulse)

·

B/L2: 267 (pulse)

·

FOOT-R: 297 (pulse)

·

FOOT: 297 (pulse)

·

FOOT-D: 305 (pulse)

·

FOOT-0: 288 (pulse)

·

F/D: 320 (pulse)

·

DEF-FOOT: 339 (pulse)

·

DEF or SHUT: 348 (pulse)


for RHD:
·

FACE-R: 271 (pulse)

·

FACE: 256 (pulse)

·

FACE1: 256 (pulse)

·

FACE2: 256 (pulse)

·

B/L: 245 (pulse)

·

B/L2: 245 (pulse)

·

FOOT-R: 215 (pulse)

·

FOOT: 215 (pulse)

·

FOOT-D: 207 (pulse)

·

FOOT-0: 224 (pulse)

·

F/D: 192 (pulse)

·

DEF-FOOT: 173 (pulse)

·

DEF or SHUT: 164 (pulse)


for LHD:

No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) circuit malfunction*1


for RHD:

No. 4 air conditioning radiator damper servo sub-assembly circuit malfunction


Air Outlet Servo Actu Pulse(P)
for LHD:

No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) actual pulse


for RHD:

No. 4 air conditioning radiator damper servo sub-assembly actual pulse


Min.: 128
Max.: 383
for LHD:
·

FACE-R: 241 (pulse)

·

FACE: 256 (pulse)

·

FACE1: 256 (pulse)

·

FACE2: 256 (pulse)

·

B/L: 267 (pulse)

·

B/L2: 267 (pulse)

·

FOOT-R: 297 (pulse)

·

FOOT: 297 (pulse)

·

FOOT-D: 305 (pulse)

·

FOOT-0: 288 (pulse)

·

F/D: 320 (pulse)

·

DEF-FOOT: 339 (pulse)

·

DEF or SHUT: 348 (pulse)


for RHD:
·

FACE-R: 271 (pulse)

·

FACE: 256 (pulse)

·

FACE1: 256 (pulse)

·

FACE2: 256 (pulse)

·

B/L: 245 (pulse)

·

B/L2: 245 (pulse)

·

FOOT-R: 215 (pulse)

·

FOOT: 215 (pulse)

·

FOOT-D: 207 (pulse)

·

FOOT-0: 224 (pulse)

·

F/D: 192 (pulse)

·

DEF-FOOT: 173 (pulse)

·

DEF or SHUT: 164 (pulse)


for LHD:

No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) circuit malfunction*1


for RHD:

No. 4 air conditioning radiator damper servo sub-assembly circuit malfunction


Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly target pulse Min.: 128
Max.: 383
for 2-tier Type:
·

Recirculation: 256 (pulse)

·

Fresh: 220 (pulse)


for 1-tier Type:
·

Recirculation: 258 (pulse)

·

Fresh: 235 (pulse)


No. 1 blower damper servo sub-assembly circuit malfunction
Air Inlet Damper Actual Pulse No. 1 blower damper servo sub-assembly actual pulse Min.: 128
Max.: 383
for 2-tier Type:
·

Recirculation: 256 (pulse)

·

Fresh: 220 (pulse)


for 1-tier Type:
·

Recirculation: 258 (pulse)

·

Fresh: 235 (pulse)


No. 1 blower damper servo sub-assembly circuit malfunction
Electric Heater Count Maximum electric heater operation level Min.: 0
Max.: 2
Maximum possible operation level of electric heater displayed PTC heater circuit malfunction
Electric Heater Active Level Actual electric heater operation level Min.: 0
Max.: 2
Actual operation level of electric heater displayed PTC heater circuit malfunction
Compressor Speed Compressor speed Min.: 0 rpm
Max.: 65535 rpm
Actual compressor speed displayed -
Compressor Target Speed Compressor target speed Min.: 0 rpm
Max.: 65535 rpm
Compressor target speed displayed -
Shift Set Temperature Shift set temperature 2C decr, 1C decr, Normal, 1C incr or 2C incr Customized value displayed -
Air Inlet Mode Air inlet mode Auto or Manual Customized value displayed -
Compressor Mode Compressor mode Auto or Manual Customized value displayed -
Noise and Vibration Reduction Function to change the speed of the compressor when set to ON OFF or ON Customized value displayed -
ECO MODE Cancel Function to cancel ECO mode when set to ON OFF or ON Customized value displayed -
ECO Switch ECO switch assembly (electric parking brake switch assembly) OFF or ON OFF: ECO switch assembly (electric parking brake switch assembly) not pushed
ON: ECO switch assembly (electric parking brake switch assembly) pushed and held
ECO switch assembly (electric parking brake switch assembly) circuit malfunction
Refrigerant Shortage Check Refrigerant shortage check ON or OFF Customized value displayed -
Fan speed increment control Fan speed increment control Slow, Normal or Fast Customized value displayed -
Foot/DEF Auto Mode Foot/defroster auto mode ON or OFF Customized value displayed -
Foot/DEF Auto Blow Up Foot/defroster auto blower speed increase ON or OFF Customized value displayed -
Ambient Temperature Shift Ambient temperature shift 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr or 3C incr Customized value displayed -
Compressor Drive Check Compressor drive check OK or NG OK: Compressor drives
NG: Compressor does not drive
-
Ion Generate Control Ion generator switch function ON or OFF Customized value displayed *2
Refrigerant Gas Type Refrigerant gas type R134a or 1234yf Refrigerant gas type displayed -
Set Temperature (D Side) Driver side set temperature Min.: MAX COLD
Max.: MAX HOT
Driver side set temperature displayed -
Set Temperature (P Side) Front passenger side set temperature Min.: MAX COLD
Max.: MAX HOT
Front passenger side set temperature displayed -
Set Temperature (Rear) Rear side set temperature Min.: MAX COLD
Max.: MAX HOT
Rear side set temperature displayed *1
Outside Air Mode Auto Switch Function Outside air mode auto switch function ON or OFF Customized value displayed -
Number of Trouble Codes Number of trouble codes Min.: 0
Max.: 255
Number of DTCs displayed -
Refrigerant High Pressure History Refrigerant high pressure history Min.: 0
Max.: 255
Number of times refrigerant high pressure history stored displayed *3

*1: for 3 Zone Type

*2: w/ Ion Generator

*3: Refer to the following procedure to clear the refrigerant high pressure history.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>UTILITY


Powertrain > Engine > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Coolant Temperature Engine coolant temperature Min.: -40°C (-40°F)
Max.: 140°C (284°F)
75 to 100°C (167 to 212°F): After warming up This is the engine coolant temperature.
HINT:
·

After warming up the engine, the engine coolant temperature will be 75 to 100°C (167 to 212°F).

·

After a long soak, the engine coolant temperature, intake air temperature and ambient air temperature will be approximately equal.

·

If the value is -40°C (-40°F), or higher than 135°C (275°F), the sensor circuit is open or shorted.

·

Check if the engine overheats if the value indicated is higher than 135°C (275°F).





ACTIVE TEST


HINT:

Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus:

i.

for Air Conditioner: Body Electrical / Air Conditioner / Active Test.


ii.

for Engine: Powertrain / Engine / Active Test.



e.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Blower Motor Blower motor with fan sub-assembly Min.: 0
Max.: 31
-
Compressor Target Speed Compressor with motor assembly Min.: 0
Max.: 7500
-
Defogger Relay (Rear) Rear window defogger OFF or ON -
Heater Active Level Quick heater assembly Min.: 0
Max.: 2
-
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse Min.: 128
Max.: 383
for LHD:

Operates between 165 to 257 pulses


for RHD:

Operates between 255 to 347 pulses


Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse Min.: 128
Max.: 383
for LHD:

Operates between 255 to 347 pulses


for RHD:

Operates between 165 to 257 pulses


Air Outlet Servo Pulse (D)
for LHD (for 3 Zone Type):

No. 4 air conditioning radiator damper servo sub-assembly pulse


for LHD (except 3 Zone Type):

No. 1 air conditioning radiator damper servo sub-assembly (mode) pulse


for RHD:

No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) pulse


Min.: 128
Max.: 383
for LHD (for 3 Zone Type):

Operates between 164 to 271 pulses


for LHD (except 3 Zone Type):

Operates between 241 to 348 pulses


for RHD:

Operates between 241 to 348 pulses


Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly pulse Min.: 128
Max.: 383
for 2-tier Type

Operates between 220 to 256 pulses


for 1-tier Type

Operates between 235 to 258 pulses


Rear Air Mix Servo Targ Pulse No. 3 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 165 to 257 pulses*1
Air Outlet Servo Pulse (P)
for LHD:

No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) pulse


for RHD:

No. 4 air conditioning radiator damper servo sub-assembly pulse


Min.: 128
Max.: 383
for LHD:

Operates between 241 to 348 pulses*1


for RHD:

Operates between 164 to 271 pulses


A/O Servo Pulse(Rr D) No. 2 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 158 to 260 pulses
Ion Generator Ion generator sub-assembly OFF or ON *2

*1: for 3 Zone Type

*2: w/ Ion Generator


Powertrain > Engine > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Control the Engine Cooling Fan Duty Ratio Control the cooling fan 0 to 100% Perform this test when vehicle is stopped.