HYBRID VEHICLE CONTROL ECU ASSEMBLY
| Terminal No.
(Symbol) |
Wiring Color | Terminal Description | Input/Output | Condition | Specified Condition |
|---|---|---|---|---|---|
| A28-1 (+B2) - K69-6 (E1) | W - W-B | Power source | Input | Power switch on (IG) | 11 to 14 V |
| A28-3 (IG2) - K69-6 (E1) | B - W-B | Power source | Input | Power switch on (IG) | 11 to 14 V |
| A28-8 (VCP2) - A28-18 (EPA2) | SB - P | Accelerator pedal sensor assembly power source (for VPA2) | Output | Power switch on (IG) | 4.5 to 5.5 V |
| A28-9 (VCPA) - A28-20 (EPA) | BE - L | Accelerator pedal sensor assembly power source (for VPA) | Output | Power switch on (IG) | 4.5 to 5.5 V |
| A28-13 (IWP) - K69-6 (E1) | L - W-B | Inverter water pump with motor assembly signal | Output | Power switch on (READY) | Pulse generation (Waveform 1) |
| A28-14 (NIWP) - K69-6 (E1) | W - W-B | Inverter water pump with motor assembly signal | Input | Power switch on (READY) | Pulse generation (Waveform 1) |
| A28-15 (STP) - K69-6 (E1) | LA-G - W-B | Stop light switch | Input | Brake pedal depressed | 11 to 14 V |
| Brake pedal released | 0 to 1.5 V | ||||
| A28-17 (LIN3) - K69-6 (E1) | L - W-B | LIN communication signal (A/C inverter, auxiliary battery state sensor) | Input/Output | Power switch on (READY) | Pulse generation |
| A28-21 (TTA) - A28-31 (ETTA) | GR - SB | Transmission fluid temperature sensor | Input | Power switch on (IG), temperature 25°C (77°F) | 3.6 to 4.6 V |
| Power switch on (IG), temperature 60°C (140°F) | 2.2 to 3.2 V | ||||
| A28-22 (ACCI) - K69-6 (E1) | P - W-B | ACC relay | Input | Power switch on (ACC) | 11 to 14 V |
| A28-24 (MMT) - A28-23 (MMTG) | G - R | Motor temperature sensor | Input | Power switch on (IG), temperature 25°C (77°F) | 3.6 to 4.6 V |
| Power switch on (IG), temperature 60°C (140°F) | 2.2 to 3.2 V | ||||
| A28-26 (GMT) - A28-27 (GMTG) | P - V | Generator temperature sensor | Input | Power switch on (IG), temperature 25°C (77°F) | 3.6 to 4.6 V |
| Power switch on (IG), temperature 60°C (140°F) | 2.2 to 3.2 V | ||||
| A28-28 (VPA2) - A28-18 (EPA2) | GR - P | Accelerator pedal sensor assembly (for accelerator pedal position detection) | Input | Power switch on (IG), accelerator pedal released | 1.0 to 2.2 V |
| Power switch on (IG), engine stopped, shift lever in P, accelerator pedal fully depressed | 3.4 to 5.3 V | ||||
| A28-30 (VPA) - A28-20 (EPA) | G - L | Accelerator pedal sensor assembly (for accelerator pedal position detection) | Input | Power switch on (IG), accelerator pedal released | 0.4 to 1.4 V |
| Power switch on (IG), engine stopped, shift lever in P, accelerator pedal fully depressed | 2.6 to 4.5 V | ||||
| A29-1 (PSFT) - K69-6 (E1) | L - W-B | Shift lever position sensor power source | Output | Power switch on (ACC) | 7.5 to 14 V |
| A29-2 (BL) - K69-6 (E1) | BE - W-B | Back-up light | Output | Power switch on (IG), shift lever in R | 11 to 14 V |
| A29-4 (+B1) - K69-6 (E1) | R - W-B | Power source | Input | Power switch on (IG) | 11 to 14 V |
| A29-6 (MREL) - K69-6 (E1) | G - W-B | Main relay | Output | Power switch on (IG) | 11 to 14 V |
| A29-7 (IGB) - K69-6 (E1) | B - W-B | Power source | Input | Power switch on (IG) | 8.5 to 14 V |
| A29-12 (HSDN) - K69-6 (E1) | W - W-B | MG ECU shutdown signal | Output | Power switch on (READY) | 0 to 1.5 V |
| A29-13 (ILK) - K69-6 (E1) | GR - W-B | Interlock switch | Input | Power switch on (IG), service plug grip installed correctly | 0 to 1.5 V |
| Power switch on (IG), service plug grip not installed | 11 to 14 V | ||||
| A29-14 (DB2) - K69-6 (E1) | V - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in D or S | 7.5 to 14 V |
| Power switch on (IG), shift lever not in D or S | 0 to 1.5 V | ||||
| A29-15 (R) - K69-6 (E1) | LG - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in R | 7.5 to 14 V |
| Power switch on (IG), shift lever not in R | 0 to 1.5 V | ||||
| A29-17 (PR) - K69-6 (E1) | R - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in P or R | 7.5 to 14 V |
| Power switch on (IG), shift lever not in P or R | 0 to 1.5 V | ||||
| A29-20 (N) - K69-6 (E1) | G - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in N | 7.5 to 14 V |
| Power switch on (IG), shift lever not in N | 0 to 1.5 V | ||||
| A29-21 (P) - K69-6 (E1) | BE - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in P | 7.5 to 14 V |
| Power switch on (IG), shift lever not in P | 0 to 1.5 V | ||||
| A29-26 (DB1) - K69-6 (E1) | W - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in D or S | 7.5 to 14 V |
| Power switch on (IG), shift lever not in D or S | 0 to 1.5 V | ||||
| A29-28 (ST1-) - K69-6 (E1) | LG - W-B | Stop light switch signal | Input | Power switch on (IG), brake pedal depressed | 0 to 1.5 V |
| Power switch on (IG), brake pedal released | 11 to 14 V | ||||
| A29-30 (HMCL) - K69-6 (E1) | W - W-B | MG ECU communication request signal | Input/Output | Power switch on (IG) | Pulse generation (Waveform 2) |
| A29-31 (HMCH) - K69-6 (E1) | B - W-B | MG ECU communication request signal | Input/Output | Power switch on (IG) | Pulse generation (Waveform 2) |
| A29-34 (PNB) - K69-6 (E1) | B - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in P or N | 7.5 to 14 V |
| K69-1 (SMRG) - K69-5 (E01) | G - W-B | System main relay operation signal | Output | Power switch on (IG) → Power switch on (READY) | Pulse generation (Waveform 3) |
| K69-3 (SMRP) - K69-5 (E01) | W - W-B | System main relay operation signal | Output | Power switch on (IG) → Power switch on (READY) | Pulse generation (Waveform 3) |
| K69-4 (SMRB) - K69-5 (E01) | GR - W-B | System main relay operation signal | Output | Power switch on (IG) → Power switch on (READY) | Pulse generation (Waveform 3) |
| K69-7 (KOK) - K69-6 (E1) | BE - W-B | Vehicle proximity notification system permission signal | Output | Power switch on (IG) | 0 to 2.0 V |
| K69-8 (INDR) - K69-6 (E1) | LG - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in R | 0 to 3.2 V |
| Power switch on (IG), shift lever not in R | 11 to 14 V | ||||
| K69-9 (ST2) - K69-6 (E1) | L - W-B | Starter signal | Input | Power switch on (IG) | 0 to 1.5 V |
| K69-10 (NORM) - K69-6(E1) | LG - W-B | Normal mode switch (electric parking brake switch assembly) signal | Input | Power switch on (IG), normal mode switch (electric parking brake switch assembly) not operated | 11 to 14 V |
| Power switch on (IG), normal mode switch (electric parking brake switch assembly) operated | 0 to 1.5 V | ||||
| K69-32 (BTH+) - K69-6 (E1) | LG - W-B | Communication signal from battery voltage sensor to hybrid vehicle ECU assembly | Input | Power switch on (IG) | Pulse generation (Waveform 4) |
| K69-33 (BTH-) - K69-6 (E1) | W - W-B | Communication signal from battery voltage sensor to hybrid vehicle ECU assembly | Input | Power switch on (IG) | Pulse generation (Waveform 4) |
| K70-1 (M) - K69-6 (E1) | B - W-B | Transmission control | Input | Power switch on (IG), shift lever in S | 11 to 14 V |
| Power switch on (IG), shift lever not in S | 0 to 1.5 V | ||||
| K70-3 (BATT) - K69-6 (E1) | B - W-B | Constant power source | Input | Power switch on (IG) | 11 to 14 V |
| Power switch on (READY) | 11 to 15.5 V | ||||
| K70-6 (SPRT) - K69-6 (E1) | R - W-B | Sport mode switch (electric parking brake switch assembly) signal | Input | Power switch on (IG), sport mode switch (electric parking brake switch assembly) not operated | 11 to 14 V |
| Power switch on (IG), sport mode switch (electric parking brake switch assembly) operated | 0 to 1.5 V | ||||
| K70-7 (PLKC) - K69-6 (E1) | L - W-B | Shift lock release request signal | Output | Power switch on (READY), brake pedal depressed | 11 to 14 V |
| Power switch on (READY), brake pedal released | 0 to 1.5 V | ||||
| K70-8 (SFTD) - K69-6 (E1) | W - W-B*1
G - W-B*2 |
Transmission control | Input | Power switch on (IG), shift lever in S | 11 to 14 V |
| Power switch on (IG), shift lever in (-) or shift paddle switch LH operated | 0 to 1.5 V | ||||
| K70-9 (SFTU) - K69-6 (E1) | LG - W-B*1
L - W-B*2 |
Transmission control | Input | Power switch on (IG), shift lever in S | 11 to 14 V |
| Power switch on (IG), shift lever in (+) or shift paddle switch RH operated | 0 to 1.5 V | ||||
| K70-10 (INDM) - K69-6 (E1) | GR - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in S | 0 to 3.2 V |
| Power switch on (IG), shift lever not in S | 11 to 14 V | ||||
| K70-11 (INDD) - K69-6 (E1) | W - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in D | 0 to 3.2 V |
| Power switch on (IG), shift lever not in D | 11 to 14 V | ||||
| K70-12 (INDN) - K69-6 (E1) | R - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in N | 0 to 3.2 V |
| Power switch on (IG), shift lever not in N | 11 to 14 V | ||||
| K70-13 (INDP) - K69-6 (E1) | L - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in P | 0 to 3.2 V |
| Power switch on (IG), shift lever not in P | 11 to 14 V | ||||
| K70-14 (ABFS) - K69-6 (E1) | B - W-B | Airbag activation signal | Input | Power switch on (READY) | Pulse generation (Waveform 5) |
| K70-15 (EVSW) - K69-6 (E1) | G - W-B | EV drive mode switch (electric parking brake switch assembly) signal | Input | Power switch on (IG), EV drive mode switch (electric parking brake switch assembly) not operated | 11 to 14 V |
| Power switch on (IG), EV drive mode switch (electric parking brake switch assembly) operated | 0 to 1.5 V | ||||
| K70-24 (CA1L) - K69-6 (E1) | W - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation (Waveform 6) |
| K70-25 (CA1H) - K69-6 (E1) | L - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation (Waveform 6) |
| K70-28 (TC) - K69-6 (E1) | GR - W-B | Diagnosis terminal | Input | Power switch on (IG) | 11 to 14 V |
| K70-29 (SI0) - K69-6 (E1) | L - W-B | HV battery cooling blower assembly operation signal | Output | Cooling fans operating | Pulse generation (Waveform 7) |
| Cooling fans not operating | 4.5 to 5.5 V | ||||
| K70-30 (CA3N) - K69-6 (E1) | W - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation (Waveform 8) |
| K70-31 (CA3P) - K69-6 (E1) | G - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation (Waveform 8) |
*1: w/ Shift Paddle Switch
*2: w/o Shift Paddle Switch
Oscilloscope waveforms
Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.
Waveform 1 (Inverter water pump assembly signal)
| Item | Content |
|---|---|
| Terminal | CH1: A28-13 (IWP) - K69-6 (E1)
CH2: A28-14 (NIWP) - K69-6 (E1) |
| Equipment Setting | 5 V/DIV., 20 ms./DIV. |
| Condition | Power switch on (READY) |
The duty of the IWP signal and the frequency of the NIWP signal change according to the coolant (for inverter) temperature.
Waveform 2 (MG ECU communication request signal)
| Item | Content |
|---|---|
| Terminal | CH1: A29-31 (HMCH) - K69-6 (E1)
CH2: A29-30 (HMCL) - K69-6 (E1) |
| Equipment Setting | 1 V/DIV., 50 μs./DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 3 (System main relay operation signal)
| Item | Content |
|---|---|
| Terminal | CH1: K69-3 (SMRP) - K69-5 (E01)
CH2: K69-4 (SMRB) - K69-5 (E01) CH3: K69-1 (SMRG) - K69-5 (E01) |
| Equipment Setting | 10 V/DIV., 200 ms./DIV. |
| Condition | Power switch on (IG) → Power switch on (READY) |
Waveform 4 (Communication signal from battery voltage sensor to hybrid vehicle control ECU assembly)
| Item | Content |
|---|---|
| Terminal | CH1: K69-32 (BTH+) - K69-6 (E1)
CH2: K69-33 (BTH-) - K69-6 (E1) |
| Equipment Setting | 2 V/DIV., 500 μs./DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 5 (Airbag activation signal)
| Item | Content |
|---|---|
| Terminal | K70-14 (ABFS) - K69-6 (E1) |
| Equipment Setting | 5 V/DIV., 150 ms./DIV. |
| Condition | Power switch on (READY) |
Waveform 6 (CAN communication signal)
| Item | Content |
|---|---|
| Terminal | CH1: K70-25 (CA1H) - K69-6 (E1)
CH2: K70-24 (CA1L) - K69-6 (E1) |
| Equipment Setting | 1 V/DIV., 50 μs./DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 7 (HV battery blower fan operation signal)
| Item | Content |
|---|---|
| Terminal | K70-29 (SI0) - K69-6 (E1) |
| Equipment Setting | 10 V/DIV., 1 ms./DIV. |
| Condition | Cooling fans operating |
The waveform will vary with the operating speed of the battery cooling blower assembly.
Waveform 8 (CAN communication signal)
| Item | Content |
|---|---|
| Terminal | CH1: K70-31 (CA3P) - K69-6 (E1)
CH2: K70-30 (CA3N) - K69-6 (E1) |
| Equipment Setting | 1 V/DIV., 50 μs./DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).
BATTERY VOLTAGE SENSOR
| Terminal No.
(Symbol) |
Wiring Color | Input/Output | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|---|
| z17-1 (TC0) - z17-7 (GC0) | G - G | IN | Intake air temperature sensor | Power switch on (IG), HV battery intake air temperature: -40 to 90°C (-40 to 194°F) | 4.8 (-40°C (-40°F)) to 1.0 V (90°C (194°F)) |
| z17-2 (TB2) - z17-8 (GB2) | R - R | IN | Battery temperature sensor 2 | Power switch on (IG), HV battery intake air temperature: -40 to 90°C (-40 to 194°F) | 4.8 (-40°C (-40°F)) to 1.0 V (90°C (194°F)) |
| z17-3 (TB1) - z17-9 (GB1) | W - W | IN | Battery temperature sensor 1 | Power switch on (IG), HV battery intake air temperature: -40 to 90°C (-40 to 194°F) | 4.8 (-40°C (-40°F)) to 1.0 V (90°C (194°F)) |
| z17-4 (TB0) - z17-10 (GB0) | L - L | IN | Battery temperature sensor 0 | Power switch on (IG), HV battery intake air temperature: -40 to 90°C (-40 to 194°F) | 4.8 (-40°C (-40°F)) to 1.0 V (90°C (194°F)) |
| z17-5 (IB0) - z17-12 (GIB) | Y - B | IN | Battery current sensor | Power switch on (IG) | 0.5 to 4.5 V |
| z17-6 (VIB) - z17-12 (GIB) | BR - B | OUT | Power source for battery current sensor | Power switch on (IG) | 4.5 to 5.5 V |
| R21-1 (IGCT) - R21-5 (GND) | BE - W-B | IN | Control signal | Power switch on (IG) | 11 to 14 V |
| R21-2 (BTH+) - R21-5 (GND) | GR - W-B | OUT | Serial communication | Power switch on (IG) | Pulse generation
(waveform 1) |
| R21-3 (BTH-) - R21-5 (GND) | W - W-B | OUT | Serial communication | Power switch on (IG) | Pulse generation
(waveform 2) |
| R21-5 (GND) - Body ground | W-B | - | Ground | Always (continuity check) | Below 1 Ω |
| R21-8 (FP0) - R21-5 (GND) | B - W-B | IN | Battery cooling blower monitor signal | Cooling blower stopped | 0 Hz |
| Cooling blower activated | Pulse generation
(waveform 3) |
Oscilloscope waveforms
Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.
Waveform 1 (Serial communication)
| Item | Content |
|---|---|
| Terminal | R21-2 (BTH+) - R21-5 (GND) |
| Equipment Setting | 2 V/DIV., 500 μs/DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 2 (Serial communication)
| Item | Content |
|---|---|
| Terminal | R21-3 (BTH-) - R21-5 (GND) |
| Equipment Setting | 2 V/DIV., 500 μs/DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 3 (Battery cooling blower monitor signal)
| Item | Content |
|---|---|
| Terminal | R21-8 (FP0) - R21-5 (GND) |
| Equipment Setting | 2 V/DIV., 2 ms/DIV. |
| Condition | Battery cooling blower assembly operating (Active Test of cooling fan being performed) |
The frequency of the waveform will vary with the operating speed of the battery cooling blower assembly.