This circuit detects the power switch on (IG) or off condition, and sends it to the main body ECU (multiplex network body ECU).
Inspect the fuses for circuits related to this system before performing the following procedure.
First, check for entry and start system (for Start Function) DTCs, and after confirming that there is no malfunction, proceed with troubleshooting.
Before replacing the main body ECU (multiplex network body ECU), refer to Service Bulletin.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Main Body / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| IG SW | Power switch on (IG) signal | OFF or ON | OFF: Power switch off
ON: Power switch on (IG) |
"OFF" is also displayed for this item when the power switch is on (ACC). |
| Tester Display |
|---|
| IG SW |
Normal conditions listed above are displayed.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the 3F*1 or 3G*2 and 3B instrument panel junction block assembly connectors.
Disconnect the K51 main body ECU (multiplex network body ECU) connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3F-1 - Body ground*1 | Power switch off | 11 to 14 V |
| 3G-1 - Body ground*2 | Power switch off | 11 to 14 V |
*1: for LHD
*2: for RHD
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3B-3 - Body ground | Always | Below 1 Ω |
| K51-19 (GND2) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *A | for LHD | *B | for RHD |
| *a | Component without harness connected
(Instrument Panel Junction Block Assembly) |
- | - |
Remove the instrument panel junction block assembly.
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3F-1 - MB-32 (IG) | Auxiliary battery not connected to 3A-17 and 3B-3 | 10 kΩ or higher |
| 3F-1 - MB-32 (IG) | Auxiliary battery positive (+) → 3A-17
Auxiliary battery negative (-) → 3B-3 |
Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3G-1 - MB-32 (IG) | Auxiliary battery not connected to 3A-17 and 3B-3 | 10 kΩ or higher |
| 3G-1 - MB-32 (IG) | Auxiliary battery positive (+) → 3A-17
Auxiliary battery negative (-) → 3B-3 |
Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG