Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY) › from 2020.08
RM33C0E _51 Engine / Hybrid System _065433 HYBRID / BATTERY CONTROL _0442441 MOTOR GENERATOR CONTROL SYSTEM(for LITHIUM-ION BATTERY) C

HYBRID / BATTERY CONTROL  MOTOR GENERATOR CONTROL SYSTEM(for LITHIUM-ION BATTERY)  P0A1112  DC/DC Converter Enable Circuit Short to Battery  P0A1114  DC/DC Converter Enable Circuit Short to Ground or Open  


DESCRIPTION

Refer to the description for DTC P1CCC96.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY)>P1CCC96

The motor generator control ECU sends a signal to the DC/DC converter to prohibit its control and receives signals indicating a normal or abnormal (below 11 V) condition of the 12 V charging system from the DC/DC converter via the NODD signal line.

If the vehicle is being driven with an inoperative DC/DC converter, the voltage of the auxiliary battery will drop, which will prevent the continued operation of the vehicle. Therefore, the motor generator control ECU monitors the operation of the DC/DC converter and alerts the driver if it detects a malfunction.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0A1112 DC/DC Converter Enable Circuit Short to Battery Short to +B detected in DC/DC converter NODD signal line
(1 trip detection logic)
·

Wire harness or connector

·

Inverter with converter assembly


Does not come on Master Warning Light:
Comes on
P0A1114 DC/DC Converter Enable Circuit Short to Ground or Open Open or short to ground detected in DC/DC converter NODD signal line
(1 trip detection logic)
·

Wire harness or connector

·

Inverter with converter assembly


Does not come on Master Warning Light:
Comes on

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY)>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

With power switch on (IG) and wait for 10 seconds or more.

7.

Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.

8.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




WIRING DIAGRAM

A443576E32
0.125,1.198 0.99,1.573 0.865,0.375 10 false from Auxiliary Battery 1.594,1.365 2.24,1.646 0.646,0.281 10 false IGCT 3.427,1.438 4.229,1.688 0.802,0.25 10 false IGCT NO. 2 2.458,1.885 2.833,2.135 0.375,0.25 10 false IGCT 3.75,2.333 4.385,2.531 0.635,0.198 10 false MREL 3.146,3.25 3.521,3.5 0.375,0.25 10 false A29 5.469,3.583 5.844,3.833 0.375,0.25 10 false A48 5.49,3.76 6.854,4.365 1.365,0.604 10 false Inverter with Converter Assembly 3.135,3.427 4.51,4.021 1.375,0.594 10 false Hybrid Vehicle Control ECU Assembly 5.729,1.219 6.323,1.51 0.594,0.292 10 false IGCT 5.75,2.49 6.302,2.708 0.552,0.219 10 false GND1 5.75,3.146 6.302,3.406 0.552,0.26 10 false GND2 5.438,1.104 5.698,1.385 0.26,0.281 10 false 12 5.458,3.042 5.719,3.323 0.26,0.281 10 false 23 5.458,2.365 5.719,2.646 0.26,0.281 10 false 24 3.531,2.219 3.792,2.5 0.26,0.281 10 false 6 3.979,1.094 4.24,1.375 0.26,0.281 10 false 2 3.375,1.115 3.635,1.396 0.26,0.281 10 false 1 1.5,1.115 1.76,1.396 0.26,0.281 10 false 1 1.938,1.115 2.198,1.396 0.26,0.281 10 false 2 2.833,1.5 3.094,1.781 0.26,0.281 10 false 1 2.271,1.5 2.531,1.781 0.26,0.281 10 false 2 2.26,1.115 2.521,1.396 0.26,0.281 10 false 3 2.844,1.115 3.104,1.396 0.26,0.281 10 false 5

CAUTION / NOTICE / HINT

CAUTION:
·
A340358


·

Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C05
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY)>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


HINT:

If the NODD signal line is open, DC/DC converter control will be prohibited and the auxiliary battery voltage will be approximately 12 V or less.


PROCEDURE

1.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY)>P033500

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

2.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - IGCT RELAY)

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

2.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - IGCT RELAY)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the A48 inverter with converter assembly connector.


c.

Remove the IGCT relay from the No. 6 relay block.


d.

Measure the resistance according to the value(s) in the table below.

A409271C11
4,1.677 4.365,1.938 0.365,0.26 5.281,1.875 5.552,1.146 true 0.844,0.927 1.156,1.125 0.313,0.198 10 false *1 3.542,2.51 3.854,2.708 0.313,0.198 10 false *2 4.042,0.99 4.354,1.188 0.313,0.198 10 false *a 4.063,1.719 4.521,1.917 0.458,0.198 10 false A48 5.49,0.896 5.927,1.094 0.438,0.198 10 false IGCT 0.115,0.115 0.427,0.313 0.313,0.198 10 false *A
*A for LHD - -
*1 No. 6 Relay Block *2 IGCT Relay
*a Front view of wire harness connector
(to Inverter with Converter Assembly)
- -


A406953C08
4.073,1.771 4.479,2.042 0.406,0.271 5.25,1.875 5.635,1.01 true 1.25,0.677 1.563,0.875 0.313,0.198 10 false *1 0.917,2.354 1.229,2.552 0.313,0.198 10 false *2 4.146,0.698 4.458,0.896 0.313,0.198 10 false *a 4.146,1.833 4.604,2.031 0.458,0.198 10 false A48 5.583,0.813 6.135,1.01 0.552,0.198 10 false IGCT 0.156,0.104 0.469,0.302 0.313,0.198 10 false *A
*A for RHD - -
*1 No. 6 Relay Block *2 IGCT Relay
*a Front view of wire harness connector
(to Inverter with Converter Assembly)
- -


Standard Resistance:
Tester Connection Condition Specified Condition
A48-12 (IGCT) - 5 (IGCT relay) Power switch off Below 1 Ω



e.

Install the IGCT relay.


f.

Reconnect the A48 inverter with converter assembly connector.


Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR