Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HV RELAY ASSEMBLY (for LITHIUM-ION BATTERY) › from 2020.08
RM33C0E _51 Engine / Hybrid System _065433 HYBRID / BATTERY CONTROL _0442444 HV RELAY ASSEMBLY(for LITHIUM-ION BATTERY) G

HYBRID / BATTERY CONTROL  HV RELAY ASSEMBLY(for LITHIUM-ION BATTERY)  INSPECTION  


PROCEDURE

Hide G92Z0 1.INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY

a.

Inspect SMRB:

i.

Measure the resistance according to the value(s) in the table below.

A407179C41
3.76,1.031 4.115,1.24 0.354,0.208 5.625,0.146 6.031,0.375 0.406,0.229 3.302,0.146 3.646,0.365 0.344,0.219 3.115,1.354 3.385,1.188 true 3.771,1.354 3.604,1.177 true 3.771,0.427 3.396,0.677 true 6.292,0.698 5.802,0.698 true 0.573,0.146 0.885,0.302 0.313,0.156 10 false *a 3.813,1.063 4.271,1.26 0.458,0.198 10 false R22 2.958,1.385 3.292,1.594 0.333,0.208 10 true GND 3.667,1.385 4.094,1.594 0.427,0.208 10 true SMRB 5.688,0.167 6,0.365 0.313,0.198 10 true z25 6.323,0.604 6.479,0.802 0.156,0.198 10 false + 3.344,0.156 3.625,0.354 0.281,0.198 10 true s2 3.813,0.344 4.198,0.563 0.385,0.219 10 false CBI
*a Component without harness connected
(HV Battery Junction Block Assembly)
- -


Standard Resistance:
Tester Connection Condition Specified Condition
z25-1 (+) - s2-1 (CBI) Auxiliary battery voltage not applied between terminals R22-1 (SMRB) and R22-3 (GND) 10 kΩ or higher
z25-1 (+) - s2-1 (CBI) Auxiliary battery voltage applied between terminals R22-1 (SMRB) and R22-3 (GND) Below 1 Ω



ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
R22-1 (SMRB) - R22-3 (GND) -40 to 80°C (-40 to 176°F) 25.0 to 59.0 Ω


If the result is not as specified, replace the HV battery junction block assembly.



b.

Inspect SMRG:

i.

Measure the resistance according to the value(s) in the table below.

A477627C02
3.76,1.031 4.115,1.24 0.354,0.208 2.219,0.104 2.583,0.344 0.365,0.24 1.167,0.115 1.531,0.323 0.365,0.208 3.021,1.354 3.292,1.188 true 3.677,1.365 3.427,1.198 true 2.063,1.063 2.396,0.677 true 0.833,0.854 1.344,0.656 true 0.573,0.146 0.885,0.302 0.313,0.156 10 false *a 3.823,1.052 4.281,1.25 0.458,0.198 10 false R22 3.531,1.385 3.865,1.594 0.333,0.208 10 true GND 2.771,1.385 3.219,1.583 0.448,0.198 10 true SMRG 2.281,0.156 2.552,0.313 0.271,0.156 10 true s3 1.229,0.135 1.5,0.302 0.271,0.167 10 true z27 1.813,1 2.188,1.208 0.375,0.208 10 false CEI 0.719,0.781 0.875,0.979 0.156,0.198 10 false -
*a Component without harness connected
(HV Battery Junction Block Assembly)
- -


Standard Resistance:
Tester Connection Condition Specified Condition
z27-1 (-) - s3-1 (CEI) Auxiliary battery voltage not applied between terminals R22-4 (SMRG) and R22-3 (GND) 10 kΩ or higher
z27-1 (-) - s3-1 (CEI) Auxiliary battery voltage applied between terminals R22-4 (SMRG) and R22-3 (GND) Below 1 Ω



ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
R22-4 (SMRG) - R22-3 (GND) -40 to 80°C (-40 to 176°F) 25.0 to 59.0 Ω


If the result is not as specified, replace the HV battery junction block assembly.



c.

Inspect SMRP:

i.

Measure the resistance according to the value(s) in the table below.

A477627C01
3.76,1.031 4.115,1.24 0.354,0.208 2.219,0.104 2.583,0.344 0.365,0.24 1.167,0.115 1.531,0.323 0.365,0.208 3.115,1.354 3.385,1.188 true 3.76,1.344 3.51,1.177 true 2.063,1.063 2.396,0.677 true 0.833,0.854 1.344,0.656 true 0.573,0.146 0.885,0.302 0.313,0.156 10 false *a 3.823,1.052 4.281,1.25 0.458,0.198 10 false R22 2.958,1.385 3.292,1.594 0.333,0.208 10 true GND 3.667,1.385 4.115,1.583 0.448,0.198 10 true SMRP 2.281,0.156 2.552,0.313 0.271,0.156 10 true s3 1.229,0.135 1.5,0.302 0.271,0.167 10 true z27 1.813,1 2.188,1.208 0.375,0.208 10 false CEI 0.719,0.781 0.875,0.979 0.156,0.198 10 false -
*a Component without harness connected
(HV Battery Junction Block Assembly)
- -


Standard Resistance:
Tester Connection Condition Specified Condition
z27-1 (-) - s3-1 (CEI) Auxiliary battery voltage not applied between terminals R22-2 (SMRP) and R22-3 (GND) 10 kΩ or higher
z27-1 (-) - s3-1 (CEI) Auxiliary battery voltage applied between terminals R22-2 (SMRP) and R22-3 (GND) 24.3 to 29.7 Ω



ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
R22-2 (SMRP) - R22-3 (GND) -40 to 80°C (-40 to 176°F) 140 to 290 Ω