Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM (for LITHIUM-ION BATTERY) › from 2020.08
RM33C0E _51 Engine / Hybrid System _065433 HYBRID / BATTERY CONTROL _0442936 HYBRID BATTERY SYSTEM(for LITHIUM-ION BATTERY) U

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM(for LITHIUM-ION BATTERY)  TERMINALS OF ECU  


A406222C27
4.073,1.198 4.479,1.448 0.406,0.25 3.042,1.177 3.542,1.427 0.5,0.25 1.865,1.198 2.292,1.448 0.427,0.25 0.125,0.135 0.729,0.521 0.604,0.385 10 false *1 4.135,1.24 4.448,1.417 0.313,0.177 10 true z16 3.156,1.208 3.479,1.417 0.323,0.208 10 true z15 1.906,1.24 2.219,1.417 0.313,0.177 10 true z13
*1 Battery ECU assembly - -


Terminal No.
(Symbols)
Wiring Color Input/Output Terminal Description Condition Specified Condition
z16-1 (AM) - z16-27 (GND) BR - W-G IN Constant power source Always 11 to 14 V
z16-27 (GND) - Body ground W-G Ground Ground Always Below 1 Ω
z16-3 (GND1) - Body ground GR Ground Ground Always Below 1 Ω
z16-4 (ERTH) - Body ground LG Ground Ground Always Below 1 Ω
z16-18 (TB0) - z16-17 (GB0) P - P IN Battery temperature sensor 0 Power switch on (IG)
HV battery temperature: -40 to 90°C (-40 to 194°F)
4.75 (-40°C) to 0.46 V(90°C)
z16-31 (TB1) - z16-30 (GB1) Y - Y IN Battery temperature sensor 1 Power switch on (IG)
HV battery temperature: -40 to 90°C (-40 to 194°F)
4.75 (-40°C) to 0.46 V(90°C)
z16-7 (TB2) - z16-6 (GB2) L - L IN Battery temperature sensor 2 Power switch on (IG)
HV battery temperature: -40 to 90°C (-40 to 194°F)
4.75 (-40°C) to 0.46 V(90°C)
z16-20 (TB3) - z16-19 (GB3) LG - B IN Battery temperature sensor 3 Power switch on (IG)
HV battery temperature: -40 to 90°C (-40 to 194°F)
4.75 (-40°C) to 0.46 V(90°C)
z16-33 (TB4) - z16-32 (GB4) GR - W-G IN Battery temperature sensor 4 Power switch on (IG)
HV battery temperature: -40 to 90°C (-40 to 194°F)
4.75 (-40°C) to 0.46 V(90°C)
z16-9 (TB5) - z16-8 (GB5) R - W IN Battery temperature sensor 5 Power switch on (IG)
HV battery temperature: -40 to 90°C (-40 to 194°F)
4.75 (-40°C) to 0.46 V(90°C)
z16-22 (TC0) - z16-21 (GC0) P-B - V IN Intake air temperature sensor Power switch on (IG)
HV battery intake air temperature: -40 to 90°C (-40 to 194°F)
4.75 (-40°C) to 0.46 V(90°C)
z16-12 (IB0) - z16-23 (GIB) BR- B-W IN Battery current sensor 0 Power switch on (IG) Approximately 2.8 V
z16-24 (IB1) - z16-23 (GIB) L-W - B-W IN Battery current sensor 1 Power switch on (IG) Approximately 2.2 V
z16-36 (VIB) - z16-23 (GIB) G - B-W OUT Power source for battery current sensor Power switch on (IG) 4.5 to 5.5 V
z16-13 (IGCT) - z16-27 (GND) L-W - W-G IN Power source Power switch on (IG) 11 to 15.5 V
z16-14 (SI0) - z16-27 (GND) P-B - W-G OUT HV battery cooling blower operation signal Cooling fans operating Pulse generation
(Waveform 1)
Cooling fans not operating 4.5 to 5.5 V
z16-15 (FP0) - z16-27 (GND) V - W-G IN HV battery cooling blower monitor signal Cooling fans operating Pulse generation
(Waveform 2)
Cooling fans not operating 0 Hz
z16-25 (CA1H) - z16-27 (GND) B - W-G IN/OUT CAN communication line Power switch on (IG) Pulse generation
(Waveform 3)
z16-26 (CA1L) - z16-27 (GND) LG - W-G IN/OUT CAN communication line Power switch on (IG) Pulse generation
(Waveform 3)
z16-28 (CA2L) - z16-27 (GND) W - W-G IN/OUT CAN communication line Power switch on (IG) Pulse generation
(Waveform 4)
z16-29 (CA2H) - z16-27 (GND) R - W-G IN/OUT CAN communication line Power switch on (IG) Pulse generation
(Waveform 4)
z15-1 (GA0) - z15-13 (VA1) V - P IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-13 (VA1) - z15-25 (VA2) P - L IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-25 (VA2) - z15-2 (VA3) L - W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-2 (VA3) - z15-14 (VA4) W - BR IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-14 (VA4) - z15-26 (VA5) BR - W-G IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-26 (VA5) - z15-3 (VA6) W-G - B IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-3 (VA6) - z15-15 (VA7) B - P-B IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-15 (VA7) - z15-27 (VA8) P-B - L-W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-27 (VA8) - z15-4 (VA9) L-W - LG IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-4 (VA9) - z15-16 (VA10) LG - B-W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-16 (VA10) - z15-28 (VA11) B-W - Y IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-28 (VA11) - z15-5 (VA12) Y - G IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-5 (VA12) - z15-17 (VA13) G - GR IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-17 (VA13) - z15-29 (VA14) GR - V IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-29 (VA14) - z15-6 (VA15) V - R IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-6 (VA15) - z15-18 (VA16) R - L IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-18 (VA16) - z15-30 (VA17) L - P IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-30 (VA17) - z15-7 (VA18) P - BR IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-7 (VA18) - z15-19 (VA19) BR - W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-19 (VA19) - z15-31 (VA20) W - B IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-31 (VA20) - z15-8 (VA21) B - W-G IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-8 (VA21) - z15-20 (VA22) W-G - L-W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-20 (VA22) - z15-32 (VA23) L-W - P-B IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-32 (VA23) - z15-9 (VA24) P-B - B-W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-9 (VA24) - z15-21 (VA25) B-W - LG IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-21 (VA25) - z15-33 (VA26) LG - G IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-33 (VA26) - z15-10 (VA27) G - Y IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-10 (VA27) - z15-22 (VA28) Y - V IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-22 (VA28) - z15-34 (VA29) V - GR IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-34 (VA29) - z15-11 (VA30) GR - L IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-11 (VA30) - z15-23 (VA31) L - R IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-23 (VA31) - z15-35 (VA32) R - BR IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-35 (VA32) - z15-12 (VA33) BR - P IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-12 (VA33) - z15-24 (VA34) P - B IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z15-24 (VA34) - z15-36 (VA35) B - W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-1 (VAD) - z13-13 (VA36) W - B IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-13 (VA36) - z13-25 (VA37) B - P IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-25 (VA37) - z13-2 (VA38) P - BR IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-2 (VA38) - z13-14 (VA39) BR - R IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-14 (VA39) - z13-26 (VA40) R - L IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-26 (VA40) - z13-3 (VA41) L - GR IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-3 (VA41) - z13-15 (VA42) GR - V IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-15 (VA42) - z13-27 (VA43) V - Y IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-27 (VA43) - z13-4 (VA44) Y - G IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-4 (VA44) - z13-16 (VA45) G - LG IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-16 (VA45) - z13-28 (VA46) LG - B-W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-28 (VA46) - z13-5 (VA47) B-W - P-B IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-5 (VA47) - z13-17 (VA48) P-B - L-W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-17 (VA48) - z13-29 (VA49) L-W - W-G IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-29 (VA49) - z13-6 (VA50) W-G - B IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-6 (VA50) - z13-18 (VA51) B - W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-18 (VA51) - z13-30 (VA52) W - BR IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-30 (VA52) - z13-7 (VA53) BR - P IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-7 (VA53) - z13-19 (VA54) P - L IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-19 (VA54) - z13-31 (VA55) L - R IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-31 (VA55) - z13-8 (VA56) R - V IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-8 (VA56) - z13-20 (VA57) V - GR IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-20 (VA57) - z13-32 (VA58) GR - G IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-32 (VA58) - z13-9 (VA59) G - Y IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-9 (VA59) - z13-21 (VA60) Y - B-W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-21 (VA60) - z13-33 (VA61) B-W - LG IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-33 (VA61) - z13-10 (VA62) LG - L-W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-10 (VA62) - z13-22 (VA63) L-W - P-B IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-22 (VA63) - z13-34 (VA64) P-B - B IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-34 (VA64) - z13-11 (VA65) B - W-G IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-11 (VA65) - z13-23 (VA66) W-G - BR IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-23 (VA66) - z13-35 (VA67) BR - W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-35 (VA67) - z13-12 (VA68) W - L IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-12 (VA68) - z13-24 (VA69) L - P IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z13-24 (VA69) - z13-36 (VA70) P - V IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V

Oscilloscope waveforms


HINT:

Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.


a.
C257882N01
2.99,1.052 3.302,1.292 0.313,0.24 10 GND

Waveform 1 (HV battery cooling blower operation signal)

Item Content
Terminal z16-14 (SI0) - z16-27 (GND)
Equipment Setting 10 V/DIV., 1 ms/DIV.
Condition Cooling fans operating

HINT:

The wavelength will vary with the operating speed of the battery cooling blower assembly.



b.
A298836N04
3.01,1.052 3.396,1.25 0.385,0.198 10 GND

Waveform 2 (HV battery cooling blower monitor signal)

Item Content
Terminal z16-15 (FP0) - z16-27 (GND)
Equipment Setting 2 V/DIV., 2 ms/DIV.
Condition Battery cooling blower assembly operating (Active Test of cooling fan being performed)

HINT:

The wavelength will vary with the operating speed of the battery cooling blower assembly.



c.
A298838N01
3.01,1.229 3.375,1.469 0.365,0.24 10 GND 3.031,1.604 3.396,1.844 0.365,0.24 10 GND 0.302,0.865 0.667,1.104 0.365,0.24 10 CH1 0.323,1.427 0.688,1.667 0.365,0.24 10 CH2

Waveform 3 (CAN communication line)

Item Content
Terminal CH1: z16-25 (CA1H) - z16-27 (GND)
CH2: z16-26 (CA1L) - z16-27 (GND)
Equipment Setting 1 V/DIV., 50 μs/DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



d.
A298838N01
3.01,1.229 3.375,1.469 0.365,0.24 10 GND 3.031,1.604 3.396,1.844 0.365,0.24 10 GND 0.302,0.865 0.667,1.104 0.365,0.24 10 CH1 0.323,1.427 0.688,1.667 0.365,0.24 10 CH2

Waveform 4 (CAN communication line)

Item Content
Terminal CH1: z16-29 (CA2H) - z16-27 (GND)
CH2: z16-28 (CA2L) - z16-27 (GND)
Equipment Setting 1 V/DIV., 50 μs/DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).