CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
| *A | w/o Seat Heater | *B | w/ Seat Heater |
Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.
| Terminal No.
(Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| K54-1 (B) - K54-4 (GND) | LA-B - W-B | Power source (Back-up) | Power switch off | 11 to 14 V |
| K54-2 (IG+) - K54-4 (GND) | LA-GR - W-B | Power source (IG) | Power switch on (IG) | 11 to 14 V |
| Power switch off | Below 1 V | |||
| K54-4 (GND) - Body ground | W-B - Body ground | Ground for main power supply | Always | Below 1 V |
| K54-6 (BLW) - K54-4 (GND) | LG - W-B | Blower motor speed control signal | ·
Power switch on (IG) ·
Blower switch: LO |
Pulse generation
(See waveform 1) |
| K54-7 (NANO) - K54-4 (GND)*1 | LG - W-B | Ion generator sub-assembly operation signal | ·
Power switch on (IG) ·
Blower switch: On |
Below 1 V |
·
Power switch on (IG) ·
Blower switch: Off |
4.75 to 5.25 V | |||
| K54-11 (CANH) - K54-12 (CANL) | SB - W | CAN communication system | CAN communication is performed | Pulse generation |
| K54-14 (LIN1) - K54-4 (GND) | BE - W-B | LIN communication signal | Power switch on (IG) | Pulse generation
(See waveform 2) |
| K54-26 (NAIN) - K54-4 (GND)*1 | BE - W-B | Ion generator sub-assembly operation condition signal | ·
Power switch on (IG) ·
Blower switch: On |
Below 2.2 V |
·
Power switch on (IG) ·
Blower switch: Off |
4.75 to 5.25 V | |||
| K55-1 (SG-1) - Body ground | LG - Body ground | Ground for cooler (room temp. sensor) thermistor | Always | Below 1 V |
| K55-2 (SG-2) - Body ground | W - Body ground | Ground for thermistor assembly | Always | Below 1 V |
| K55-3 (SG-4) - Body ground | L - Body ground | Ground for air conditioner pressure sensor | Always | Below 1 V |
| K55-6 (S5-3) - K55-3 (SG-4) | GR - L | Power supply for air conditioner pressure sensor | Power switch on (IG) | 4.75 to 5.25 V |
| Power switch off | Below 1 V | |||
| K55-13 (TAM) - K55-2 (SG-2) | R - W | Thermistor assembly signal | ·
Power switch on (IG) ·
Ambient temperature: 25°C (77°F) |
1.05 to 1.45 V |
·
Power switch on (IG) ·
Ambient temperature: 40°C (104°F) |
0.64 to 0.87 V | |||
| K55-14 (TR) - K55-1 (SG-1) | GR - LG | Cooler (room temp. sensor) thermistor signal | ·
Power switch on (IG) ·
Cabin temperature: 25°C (77°F) |
1.05 to 1.45 V |
·
Power switch on (IG) ·
Cabin temperature: 40°C (104°F) |
0.64 to 0.87 V | |||
| K55-20 (ECOS) - K54-4 (GND) | W - W-B | ECO switch assembly (electric parking brake switch assembly) signal | ·
Power switch on (IG) ·
ECO switch assembly (electric parking brake switch assembly): off |
11 to 14 V |
·
Power switch on (IG) ·
ECO switch assembly (electric parking brake switch assembly): On |
Below 1 V | |||
| K55-24 (PRE) - K55-3 (SG-4) | W - L | Air conditioner pressure sensor signal | ·
Power switch on (READY) ·
Air conditioning system operating ·
Refrigerant pressure: Abnormal pressure (more than 3.025 MPaG (30.8 kgf/cm2, 439 psi)*2, more than 2.812 MPaG (28.7 kgf/cm2, 408 psi)*3) |
4.61 V or higher |
·
Power switch on (READY) ·
Air conditioning system operating ·
Refrigerant pressure: Abnormal pressure (less than 0.176 MPaG (1.8 kgf/cm2, 26 psi)*2, less than 0.196 MPaG (2.0 kgf/cm2, 28 psi) or less*3) |
Below 0.74 V | |||
·
Power switch on (READY) ·
Air conditioning system operating ·
Refrigerant pressure: Normal pressure (less than 3.025 MPaG (30.8 kgf/cm2, 439 psi) and more than 0.176 MPaG (1.8 kgf/cm2, 26 psi)*2, less than 2.812 MPaG (28.7 kgf/cm2, 408 psi) and more than 0.196 MPaG (2.0 kgf/cm2, 28 psi)*3) |
0.74 to 4.61 V | |||
| z11-2 (BUS G) - Body ground | - | Ground for BUS IC | Always | Below 1 V |
| z11-3 (BUS) - z11-2 (BUS G) | - | BUS IC control signal | Power switch on (IG) | Pulse generation
(See waveform 3) |
| z11-4 (B BUS) - z11-2 (BUS G) | - | Power supply for BUS IC | Power switch off | 11 to 14 V |
| z11-5 (SG) - Body ground | GR - Body ground | Ground for No. 1 cooler thermistor | Always | Below 1 V |
| z11-6 (TE) - z11-5 (SG) | GR - GR | No. 1 cooler thermistor signal | ·
Power switch on (IG) ·
Evaporator temperature: 0°C (32°F) |
1.7 to 2.1 V |
·
Power switch on (IG) ·
Evaporator temperature: 15°C (59°F) |
0.9 to 1.3 V |
*1: w/ Ion Generator
*2: for HFC-134a (R134a)
*3: for HFO-1234yf (R1234yf)
Waveform 1:
| Item | Content |
|---|---|
| Terminal No. | K54-6 (BLW) - K54-4 (GND) |
| Tool Setting | 2 V/DIV., 1 ms./DIV. |
| Condition | ·
Power switch on (IG) ·
Blower switch: LO |
Waveform 2:
| Item | Content |
|---|---|
| Terminal No. | K54-14 (LIN1) - K54-4 (GND) |
| Tool Setting | 2 V/DIV., 20 ms./DIV. |
| Condition | Power switch on (IG) |
Waveform 3:
| Item | Content |
|---|---|
| Terminal No. | z11-3 (BUS) - z11-2 (BUS G) |
| Tool Setting | 2 V/DIV., 2 ms./DIV. |
| Condition | Power switch on (IG) |
CHECK AIR CONDITIONING CONTROL PANEL (RADIO AND DISPLAY RECEIVER ASSEMBLY) (for 8 Inch Display)
Check from the rear of the connector while it is connected to the air conditioning control panel (radio and display receiver assembly).
| Terminal No.
(Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| h1-2 (IG+) - h1-6 (GND) | SB - W-B | Power source (IG) | Power switch off | Below 1 V |
| Power switch on (IG) | 11 to 14 V | |||
| h1-3 (+B) - h1-6 (GND) | G - W-B | Power source (Back-up) | Power switch off | 11 to 14 V |
| h1-6 (GND) - Body ground | W-B - Body ground | Ground for air conditioning control panel (radio and display receiver assembly) | Always | Below 1 V |
| h1-10 (ACC) - h1-6 (GND) | R - W-B | Power source (ACC) | Power switch off | Below 1 V |
| Power switch on (ACC) | 11 to 14 V | |||
| h1-11 (ILL+) - Body ground | W - Body ground | Illumination signal | Light control switch in off position | Below 1 V |
| Light control switch in tail or head position | 11 to 14 V | |||
| h1-15 (ILL-) - Body ground | L - Body ground | Illumination signal | Always | Below 1 V |
CHECK AIR CONDITIONING CONTROL ASSEMBLY (except 8 Inch Display)
Check from the rear of the connector while it is connected to the air conditioning control assembly.
| Terminal No.
(Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| K26-2 (IG+) - K26-6 (GND) | GR - W-B | Power source (IG) | Power switch off | Below 1 V |
| Power switch on (IG) | 11 to 14 V | |||
| K26-6 (GND) - Body ground | W-B - Body ground | Ground for air conditioning control assembly | Always | Below 1 V |
| K26-9 (LIN1) - Body ground | LG - Body ground | LIN communication signal | Power switch on (IG) | Pulse generation
(See waveform) |
| K26-11 (ILL+) - Body ground | W - Body ground | Illumination signal | Light control switch in off position | Below 1 V |
| Light control switch in tail or head position | 11 to 14 V | |||
| K26-15 (ILL-) - Body ground | B - Body ground | Illumination signal | Always | Below 1 V |
Waveform:
| Item | Content |
|---|---|
| Terminal No. | K26-9 (LIN1) - Body ground |
| Tool Setting | 2 V/DIV., 20 ms./DIV. |
| Condition | Power switch on (IG) |
COOLER CONTROL SWITCH ASSEMBLY (for 3 Zone Type)
| Terminal No.
(Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| Z1-1 (ACC) - Z1-16 (GND) | GR - W-B | Power source (ACC) | Power switch off | Below 1 V |
| Power switch on (ACC) | 11 to 14 V | |||
| Z1-9 (+B) - Z1-16 (GND) | R - W-B | Power source (+B) | Power switch off | 11 to 14 V |
| Z1-10 (IG+) - Z1-16 (GND) | L - W-B | Power source (IG) | Power switch off | Below 1 V |
| Power switch on (IG) | 11 to 14 V | |||
| Z1-11 (ILL+) - Body ground | G - Body ground | Illumination signal | Light control switch in off position | Below 1 V |
| Light control switch in tail or head position | 11 to 14 V | |||
| Z1-13 (RLIN) - Body ground | L - Body ground | LIN communication signal | Power switch on (IG) | Pulse generation
(See waveform) |
| Z1-16 (GND) - Body ground | W-B - Body ground | Ground | Always | Below 1 V |
Waveform:
| Item | Content |
|---|---|
| Terminal No. | Z1-13 (RLIN) - Body ground |
| Tool Setting | 2 V/DIV., 20 ms./DIV. |
| Condition | Power switch on (IG) |
HYBRID VEHICLE CONTROL ECU ASSEMBLY
for NICKEL METAL HYDRIDE BATTERY: Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>TERMINALS OF ECU
for LITHIUM-ION BATTERY: Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for LITHIUM-ION BATTERY)>TERMINALS OF ECU