| Item | Specified Condition |
|---|---|
| Standard Value (for Brand-new Cap) | 94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 18 psi) |
| Minimum Standard Value (for Used Cap) | 94 kPa (1.0 kgf/cm2, 13.6 psi) |
| Item | Tester Connection | Specified Condition |
|---|---|---|
| IGCT Relay (IGCT)
Resistance |
3 - 5 | 10 kΩ or higher
Auxiliary battery voltage not applied between terminals 1 and 2 |
| Below 1 Ω
Auxiliary battery voltage applied between terminals 1 and 2 |
| SMRB
Resistance |
z25-1 (+) - s2-1 (CBI) | 10 kΩ or higher
Auxiliary battery voltage not applied between terminals R22-1 (SMRB) and R22-3 (GND) |
| Below 1 Ω
Auxiliary battery voltage applied between terminals R22-1 (SMRB) and R22-3 (GND) |
||
| R25-1 (SMRB) - R22-3 (GND) | 25.0 to 59.0 Ω at -40 to 80°C (-40 to 176°F) | |
| SMRG
Resistance |
z20-1 (-) - s3-1 (CEI) | 10 kΩ or higher
Auxiliary battery voltage not applied between terminals R22-4 (SMRG) and R22-3 (GND) |
| Below 1 Ω
Auxiliary battery voltage applied between terminals R22-4 (SMRG) and R22-3 (GND) |
||
| R22-4 (SMRG) - R22-3 (GND) | 25.0 to 59.0 Ω at -40 to 80°C (-40 to 176°F) | |
| SMRP
Resistance |
z20-1 (-) - s3-1 (CEI) | 10 kΩ or higher
Auxiliary battery voltage not applied between terminals R22-2 (SMRP) and R22-3 (GND) |
| 24.3 to 29.7 Ω
Auxiliary battery voltage applied between terminals R22-2 (SMRP) and R22-3 (GND) |
||
| R22-2 (SMRP) - R22-3 (GND) | 140 to 290 Ω at -40 to 80°C (-40 to 176°F) |
| SMRB
Resistance |
z25-1 (+) - s2-1 (CBI) | 10 kΩ or higher
Auxiliary battery voltage not applied between terminals R22-1 (SMRB) and R22-3 (GND) |
| Below 1 Ω
Auxiliary battery voltage applied between terminals R22-1 (SMRB) and R22-3 (GND) |
||
| R25-1 (SMRB) - R22-3 (GND) | 25.0 to 59.0 Ω at -40 to 80°C (-40 to 176°F) | |
| SMRG
Resistance |
z27-1 (-) - s3-1 (CEI) | 10 kΩ or higher
Auxiliary battery voltage not applied between terminals R22-4 (SMRG) and R22-3 (GND) |
| Below 1 Ω
Auxiliary battery voltage applied between terminals R22-4 (SMRG) and R22-3 (GND) |
||
| R22-4 (SMRG) - R22-3 (GND) | 25.0 to 59.0 Ω at -40 to 80°C (-40 to 176°F) | |
| SMRP
Resistance |
z27-1 (-) - s3-1 (CEI) | 10 kΩ or higher
Auxiliary battery voltage not applied between terminals R22-2 (SMRP) and R22-3 (GND) |
| 24.3 to 29.7 Ω
Auxiliary battery voltage applied between terminals R22-2 (SMRP) and R22-3 (GND) |
||
| R22-2 (SMRP) - R22-3 (GND) | 140 to 290 Ω at -40 to 80°C (-40 to 176°F) |
| Electric Parking Brake Switch Assembly
Resistance |
K37-14 (S) - K37-16 (GND1) | Below 1 Ω
EV mode switch (electric parking brake switch assembly) being pushed and held |
| 10 kΩ or higher
EV mode switch (electric parking brake switch assembly) not pushed |
||
| K37-13 (B) - K37-16 (GND1) | Below 1 Ω
NORMAL mode switch (electric parking brake switch assembly) being pushed and held |
|
| 10 kΩ or higher
NORMAL mode switch (electric parking brake switch assembly) not pushed |
||
| K37-12 (P) - K37-16 (GND1) | Below 1 Ω
SPORT mode switch (electric parking brake switch assembly) being pushed and held |
|
| 10 kΩ or higher
SPORT mode switch (electric parking brake switch assembly) not pushed |
| Electric Parking Brake Switch Assembly
Resistance |
K37-11 (S) - K37-9 (GND1) | Below 1 Ω
EV mode switch (electric parking brake switch assembly) being pushed and held |
| 10 kΩ or higher
EV mode switch (electric parking brake switch assembly) not pushed |
||
| K37-12 (B) - K37-9 (GND1) | Below 1 Ω
NORMAL mode switch (electric parking brake switch assembly) being pushed and held |
|
| 10 kΩ or higher
NORMAL mode switch (electric parking brake switch assembly) not pushed |
||
| K37-13 (P) - K37-9 (GND1) | Below 1 Ω
SPORT mode switch (electric parking brake switch assembly) being pushed and held |
|
| 10 kΩ or higher
SPORT mode switch (electric parking brake switch assembly) not pushed |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Service Plug Grip | Always | Below 1 Ω |
| Hybrid Battery Terminal Block | Always | Below 1 Ω |
| Hybrid Battery Terminal Block | Always | Below 1 Ω |
| A - C | Always | Below 1 Ω |
| B - D | Below 1 Ω |